background image

LS 3408

Product Reference Guide

Содержание LS 3408

Страница 1: ...LS 3408 Product Reference Guide...

Страница 2: ......

Страница 3: ...LS 3408 Product Reference Guide 72 67133 01 Revision A February 2004...

Страница 4: ...rk from a licensed program or use a licensed program in a network without written permission from Symbol The user agrees to maintain Symbol s copyright notice on the licensed programs delivered hereun...

Страница 5: ...Service Information xvii Symbol Support Center xvii Chapter 1 Getting Started Introduction 1 3 Unpacking the Scanner 1 4 Setting Up the Scanner 1 5 Installing the Interface Cable 1 5 Connecting Power...

Страница 6: ...cifications Introduction 3 3 Maintenance 3 3 Troubleshooting 3 4 Technical Specifications 3 7 Scanner Signal Descriptions 3 9 Chapter 4 User Preferences Introduction 4 3 Scanning Sequence Examples 4 3...

Страница 7: ...n 5 11 Caps Lock On 5 11 Caps Lock Override 5 12 Convert Wedge Data 5 13 Function Key Mapping 5 13 FN1 Substitution 5 14 Send Make and Break 5 14 Keyboard Maps 5 15 ASCII Character Set 5 18 Chapter 6...

Страница 8: ...Override 7 11 USB Ignore Unknown Characters 7 12 Emulate Keypad 7 12 USB Keyboard FN 1 Substitution 7 13 Function Key Mapping 7 13 Simulated Caps Lock 7 14 Convert Case 7 14 ASCII Character Set 7 15...

Страница 9: ...ep Style 10 7 Parameter Pass Through 10 8 Convert Newer Code Types 10 9 Module Width 10 10 Convert All Bar Codes to Code 39 10 10 Code 39 Full ASCII Conversion 10 11 Transmission Timeout 10 12 Ignore...

Страница 10: ...able Disable Code 128 12 22 Enable Disable UCC EAN 128 12 23 Enable Disable ISBT 128 12 23 Code 39 12 24 Enable Disable Code 39 12 24 Enable Disable Trioptic Code 39 12 24 Convert Code 39 to Code 32 1...

Страница 11: ...CLSI Editing 12 48 NOTIS Editing 12 48 MSI 12 49 Enable Disable MSI 12 49 Set Lengths for MSI 12 49 MSI Check Digits 12 51 Transmit MSI Check Digit s 12 52 MSI Check Digit Algorithm 12 52 RSS Reduced...

Страница 12: ...ssage 13 9 Synapse Interface 13 10 Chapter 14 Advanced Data Formatting Introduction 14 3 Rules Criteria Linked to Actions 14 3 Using ADF Bar Codes 14 3 ADF Bar Code Menu Example 14 4 Rule 1 The Code 1...

Страница 13: ...14 96 Send Graphic User Interface GUI Characters 14 96 Turn On Off Rule Sets 14 103 Alphanumeric Keyboard 14 105 Appendix A Standard Default Parameters Appendix B Programming Reference Symbol Code Ide...

Страница 14: ...LS 3408 Product Reference Guide xii Appendix D Numeric Bar Codes 0 1 D 3 2 3 4 D 4 5 6 7 D 5 8 9 D 6 Cancel D 7 Glossary Index Tell Us What You Think...

Страница 15: ...About This Guide Introduction xv Chapter Descriptions xv Notational Conventions xvi Related Publications xvi Service Information xvii Symbol Support Center xvii...

Страница 16: ...LS 3408 Product Reference Guide xiv...

Страница 17: ...rovides information for setting up the scanner for Keyboard Wedge operation Chapter 6 RS 232 Interface provides information for setting up the scanner for RS 232 operation Chapter 7 USB Interface prov...

Страница 18: ...tational Conventions The following conventions are used in this document Bullets indicate action items lists of alternatives lists of required steps that are not necessarily sequential Sequential list...

Страница 19: ...e for any damages incurred during shipment if the approved shipping container is not used Shipping the units improperly can possibly void the warranty If the original shipping container was not kept c...

Страница 20: ...5407 580 Outside Finland France Symbol Technologies France Centre d Affaire d Antony 3 Rue de la Renaissance 92184 Antony Cedex France Tel 01 40 96 52 21 Inside France Tel 33 1 40 96 52 50 Outside Fr...

Страница 21: ...el 47 2232 4375 South Africa Symbol Technologies Africa Inc Block B2 Rutherford Estate 1 Scott Street Waverly 2090 Johannesburg Republic of South Africa Tel 11 809 5311 Inside South Africa Tel 27 11 8...

Страница 22: ...LS 3408 Product Reference Guide xx...

Страница 23: ...n 1 3 Unpacking the Scanner 1 4 Setting Up the Scanner 1 5 Installing the Interface Cable 1 5 Connecting Power if required 1 6 Connecting a Synapse Cable Interface 1 7 Removing the Interface Cable 1 7...

Страница 24: ...LS 3408 Product Reference Guide 1 2...

Страница 25: ...eriods of time Figure 1 1 LS 3408 Scanner This scanner supports Standard RS 232 connection to a host Keyboard Wedge connection to a host where scanned data is interpreted keystrokes The following inte...

Страница 26: ...North America German French French Canadian Spanish Italian Swedish UK English Japanese and Brazilian Portuguese Synapse capability which allows a wide variety of host systems to be connected using a...

Страница 27: ...he cable clamp at the bottom of the scanner and gently pull the clamp away from the bottom of the scanner 2 Open the clamp and plug the interface cable modular connector into the cable interface port...

Страница 28: ...nnectors may be different than those illustrated but the steps to connect the scanner remain the same Connecting Power if required If the host does not provide power to the scanner an external power c...

Страница 29: ...e on page 1 5 2 Align the S on the Synapse adapter cable with the S on the Synapse Smart Cable and plug the cable in 3 Connect the other end of the Synapse Smart Cable to the host Removing the Interfa...

Страница 30: ...or the 123Scanconfiguration program to configure the scanner See Chapter 4 User Preferences and each host chapter for information about programming the scanner using bar code menus See Chapter 11 123...

Страница 31: ...2 Scanning Introduction 2 3 Beeper Definitions 2 4 LED Definitions 2 5 Scanning in Hand Held Mode 2 6 Aiming 2 7 Scanning in Hands Free Mode 2 8 Decode Zone 2 9...

Страница 32: ...LS 3408 Product Reference Guide 2 2...

Страница 33: ...is chapter provides beeper and LED definitions techniques involved in scanning bar codes general instructions and tips about scanning and decode zone diagrams Figure 2 1 Parts Scan Trigger Scan Window...

Страница 34: ...nner remains in program mode Short high short low beep sequence Keyboard parameter selected Enter value using bar code keypad Short high short low short high short low beep sequence Successful program...

Страница 35: ...ED to indicate its status Table 2 2 defines LED colors that display during scanning Table 2 2 Standard LED Definitions LED Indication Off The scanner is on and ready to scan or no power is applied to...

Страница 36: ...ure the scanner is properly connected to the host see the appropriate host chapter 2 Aim the scanner at the bar code 3 Press the scan trigger Figure 2 2 Scanning in Hand Held Mode 4 Ensure the scan li...

Страница 37: ...to the scanner from the bar code is known as specular reflection This specular reflection can make decoding difficult The scanner can be tilted up to 65 forward or back and achieve a successful decode...

Страница 38: ...ate the scanner in the IntelliStand 1 Ensure the scanner is properly connected to the host see the appropriate host chapter for information on host connections 2 Insert the scanner into the IntelliSta...

Страница 39: ...55 mil 2 0 4 0 67 0 84 0 0 10 20 30 40 50 60 70 80 0 25 4 50 8 76 2 101 6 127 0 152 4 177 8 203 2 90 228 6 30 20 10 0 0 10 20 30 76 2 50 8 25 4 25 4 50 8 76 2 LS 3408 FZ Note Typical performance at 6...

Страница 40: ...f Field in cm W i d t h o f F i e l d in cm Note Typical performance at 73 4 F 23 C on high quality Code 39 symbols Near range determined by degree of reflectivity and width of bar code 0 25 20 7 5 mi...

Страница 41: ...3 Maintenance and Technical Specifications Introduction 3 3 Maintenance 3 3 Troubleshooting 3 4 Technical Specifications 3 7 Scanner Signal Descriptions 3 9...

Страница 42: ...LS 3408 Product Reference Guide 3 2...

Страница 43: ...escriptions pinouts Maintenance Cleaning the scan window is the only maintenance required A dirty window may affect scanning accuracy Do not allow any abrasive material to touch the window Remove any...

Страница 44: ...erwise see the technical person in charge of scanning If using RS 232 Nixdorf B mode CTS is not asserted Assert CTS line Scanner emits short low short medium short high beep sequence more than once Th...

Страница 45: ...yboard type and the CAPS LOCK key is off Ensure editing options e g UPC E to UPC A conversion are properly programmed Scanner emits short high short high short high long low beep sequence when it is n...

Страница 46: ...hort medium short high beep sequence after changing USB host type The USB bus re establishes power to the scanner Normal when the USB host type is changed Scanner emits 1 short high beep when it is no...

Страница 47: ...able Beeper Volume User selectable Three levels Beeper Tone User selectable Three tones Scan Repetition Rate 36 scans second Yaw Tolerance 50 from nominal 60 from nominal Pitch Tolerance 65 from nomin...

Страница 48: ...127 mm 7 5 mil 0 191 mm Interfaces Supported Keyboard Wedge RS 232 USB IBM 468X 469X Wand Emulation Scanner Emulation Synapse Electrical Safety Certified Pending to UL1950 CSA C22 2 No 950 EN60950 IC9...

Страница 49: ...Maintenance and Technical Specifications 3 9 Scanner Signal Descriptions Figure 3 1 Scanner Cable Pinouts Cable interface port Interface cable modular connector Bottom of scanner PIN 1 PIN 10...

Страница 50: ...6 DBP 2 Power Power Power Power Power Power Power 3 Ground Ground Ground Ground Ground Ground Ground 4 IBM_A Reserved TxD KeyClock DBP Reserved SOS 5 Reserved Reserved RxD TermData CTS D Decode 6 IBM...

Страница 51: ...Examples 4 3 Errors While Scanning 4 3 User Preferences Default Parameters 4 4 User Preferences 4 5 Set Default Parameter 4 5 Beeper Tone 4 5 Beeper Volume 4 6 Power Mode 4 7 Laser On Time 4 7 Beep Af...

Страница 52: ...LS 3408 Product Reference Guide 4 2...

Страница 53: ...up beeps select a host type This only needs to be done once upon the first power up when connected to a new host To return all features to their default values scan the Set All Defaults bar code on p...

Страница 54: ...page 4 5 See Chapter A Standard Default Parameters for all user preferences hosts symbologies and miscellaneous default parameters Table 4 1 User Preferences Default Table Parameter Default Page Numbe...

Страница 55: ...his bar code returns all parameters to the default values listed in Table A 1 on page A 3 Set All Defaults Beeper Tone To select a decode beep frequency tone scan the Low Frequency Medium Frequency or...

Страница 56: ...LS 3408 Product Reference Guide 4 6 Beeper Volume To select a beeper volume scan the Low Volume Medium Volume or High Volume bar code Low Volume Medium Volume High Volume...

Страница 57: ...ng a scan attempt It is programmable in 0 1 second increments from 0 5 to 9 9 seconds The default Laser On Time is 3 0 seconds To set a Laser On Time scan the bar code below Next scan two numeric bar...

Страница 58: ...scanner has three trigger modes that can be used to scan bar codes The desired trigger mode can be set by using the bar codes below Level Trigger When the trigger is pulled an aiming dot appears for a...

Страница 59: ...the laser on timeout occurs or a decode occurs If the trigger is pulled again while in a decode session the scanner beam returns to an aiming dot Two Stage Option 1 Two Stage Option 2 When the trigger...

Страница 60: ...le in 0 1 second increments from 0 0 to 9 9 seconds The default Aim Duration is 0 0 seconds When set to 0 0 seconds no aiming pattern appears before a decode session To set an aim duration scan the ba...

Страница 61: ...Types 5 6 Keyboard Wedge Host Types 5 6 Keyboard Wedge Country Types Country Codes 5 7 Ignore Unknown Characters 5 9 Keystroke Delay 5 9 Intra Keystroke Delay 5 10 Alternate Numeric Keypad Emulation...

Страница 62: ...LS 3408 Product Reference Guide 5 2 Keyboard Maps 5 15 ASCII Character Set 5 18...

Страница 63: ...slates the bar code data into keystrokes The host computer accepts the keystrokes as if they originate from the keyboard This mode of operation allows adding bar code reading functionality to a system...

Страница 64: ...erface port on the scanner See Installing the Interface Cable on page 1 5 3 Connect the round male DIN host connector of the Y cable to the keyboard port on the host 4 Connect the round female DIN key...

Страница 65: ...ard Wedge Host Default Table Parameter Default Page Number Keyboard Wedge Host Parameters Keyboard Wedge Host Type IBM PC AT IBM PC Compatibles 5 6 Keyboard Wedge Country Types Country Codes North Ame...

Страница 66: ...ference Guide 5 6 Keyboard Wedge Host Types Keyboard Wedge Host Types Select the keyboard wedge host by scanning one of the bar codes below IBM PC AT IBM PC Compatibles IBM PS 2 Model 30 IBM AT NOTEBO...

Страница 67: ...Codes Scan the bar code corresponding to the keyboard type If the particular keyboard type is not listed see Alternate Numeric Keypad Emulation on page 5 11 North American German Windows French Windo...

Страница 68: ...S 3408 Product Reference Guide 5 8 Keyboard Wedge Country Types Country Codes continued Spanish Windows Italian Windows Swedish Windows UK English Windows Japanese Windows Brazilian Portuguese Windows...

Страница 69: ...hen Do Not Send Bar Codes With Unknown Characters is selected bar code data is sent up to the first unknown character and then an error beep sounds on the scanner Send Bar Codes with Unknown Character...

Страница 70: ...0 msec Long Delay Intra Keystroke Delay When enabled an additional delay is inserted between each emulated key depression and release This sets the Keystroke Delay parameter to a minimum of 5 msec as...

Страница 71: ...es not listed in Keyboard Wedge Country Types Country Codes on page 5 7 in a Microsoft operating system environment Enable Alternate Numeric Keypad Disable Alternate Numeric Keypad Caps Lock On When e...

Страница 72: ...e keyboard ignores the state of the Caps Lock key Therefore an A in the bar code is sent as an A no matter what the state of the keyboard s Caps Lock key Enable Caps Lock Override Disable Caps Lock Ov...

Страница 73: ...o Not Convert Wedge Data Function Key Mapping ASCII values under 32 are normally sent as control key sequences see Table 5 2 on page 5 18 When this parameter is enabled the keys in bold are sent in pl...

Страница 74: ...f any FN1 characters in an EAN128 bar code with a keystroke chosen by the user see FN1 Substitution Values on page 9 Enable FN1 Substitution Disable FN1 Substitution Send Make and Break When enabled t...

Страница 75: ...ix values see the bar codes on page 13 6 Figure 5 2 IBM PS2 Type Keyboard Figure 5 3 IBM PC XT 7013 7014 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 7013 5011 7010 7007 7006 7001 5012 7008 7009...

Страница 76: ...NCR 7052 32 KEY 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 7009 7008 7013 7012 7004 7011 7003 7002 7014 5007 5008 5010 5002 5003 5004 5005 5006 1046 1045 5014 1043 5013 5015 5016 5018 5019 5001...

Страница 77: ...5002 5003 5004 5005 5006 1046 1045 5014 1043 5013 5015 5016 5018 5019 1086 1087 1088 1089 1090 5001 1066 1072 1073 1079 1080 1065 1070 1076 1077 1083 1084 1071 1078 1085 1069 5017 7013 5011 1082 1075...

Страница 78: ...the keystroke equivalent of ABC Table 5 2 Keyboard Wedge ASCII Character Set ASCII Value Full ASCII Code 39 Encode Character Keystroke 1001 A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CT...

Страница 79: ...L ESC1 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I Table 5 2 Keyboard Wedge ASCII Character Set Continued ASCII Va...

Страница 80: ...5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A Table 5 2 Keyboard Wedge ASCII Character Set Continued ASCII Value Full ASCII Code 39 Encode Character...

Страница 81: ...1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y Table 5 2 Keyboard Wedge ASCII Character Set Continued ASCII Value Full ASCII Code 39 Encod...

Страница 82: ...102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q Table 5 2 Keyboard Wedge ASCII Character Set Continued ASCII Value Full ASCII Code 39 Encode...

Страница 83: ...1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S Table 5 2 Keyboard Wedge ASCII Character Set Continued ASCII Value Full ASCII Code 39 Encode Character Keystroke 1 The keystroke in bold is sent...

Страница 84: ...eystroke 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082...

Страница 85: ...ight Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GU...

Страница 86: ...3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Table 5 5 Keyboard Wedge F Key Character Set F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 50...

Страница 87: ...8 F18 5019 F19 5020 F20 5021 F21 5022 F22 5023 F23 5024 F24 Table 5 6 Keyboard Wedge Numeric Keypad Character Set Numeric Keypad Keystroke 6042 6043 6044 undefined 6045 6046 6047 6048 0 6049 1 6050 2...

Страница 88: ...d Wedge Extended Keypad Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert...

Страница 89: ...Keyboard Wedge Interface 5 29 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow Table 5 7 Keyboard Wedge Extended Keypad Character Set Continued Extended Keypad Keystroke...

Страница 90: ...LS 3408 Product Reference Guide 5 30...

Страница 91: ...rs 6 5 RS 232 Host Parameters 6 6 RS 232 Host Types 6 8 Baud Rate 6 9 Parity 6 11 Check Receive Errors 6 12 Stop Bit Select 6 13 Data Bits 6 13 Hardware Handshaking 6 14 Software Handshaking 6 17 Host...

Страница 92: ...LS 3408 Product Reference Guide 6 2 Nixdorf Mode A B and OPOS JPOS Beep LED Options 6 23 Ignore Unknown Characters 6 24 ASCII Character Set 6 25...

Страница 93: ...o match the host device To set communication parameters for hosts not listed refer to the documentation for the host device This scanner utilizes TTL RS 232 signal levels which interfaces with most sy...

Страница 94: ...32 interface cable to the cable interface port on the scanner See Installing the Interface Cable on page 1 5 2 Connect the other end of the RS 232 interface cable to the serial port on the host 3 Conn...

Страница 95: ...ble 6 1 RS 232 Host Default Table Parameter Default Page Number RS 232 Host Parameters RS 232 Host Types Standard RS 232 6 8 Baud Rate 9600 6 10 Parity None 6 12 Check Receive Errors Enable 6 12 Stop...

Страница 96: ...rdware Handshaking None RTS CTS Option 3 RTS CTS Option 3 RTS CTS Option 3 None None RTS CTS Option 3 None Software Handshaking None None None None Ack Nak None None None Serial Response Time out 2 Se...

Страница 97: ...ncor Nixdorf Mode A Wincor Nixdorf Mode B Olivetti Omron OPOS JPOS Fujitsu UPC A A A A A A A A UPC E E C C C E C E EAN 8 JAN 8 FF B B B FF B FF EAN 13 JAN 13 F A A A F A F Code 39 C len M M M len C le...

Страница 98: ...t Reference Guide 6 8 RS 232 Host Types To select an RS 232 host type scan one of the following bar codes Standard RS 232 ICL RS 232 Wincor Nixdorf RS 232 Mode A Wincor Nixdorf RS 232 Mode B Olivetti...

Страница 99: ...ud Rate Baud rate is the number of bits of data transmitted per second The scanner s baud rate setting should match the baud rate setting of the host device If not data may not reach the host device o...

Страница 100: ...LS 3408 Product Reference Guide 6 10 Baud Rate continued Baud Rate 4800 Baud Rate 9600 Baud Rate 19 200 Baud Rate 38 400...

Страница 101: ...Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character Odd Select Even parity and the parity bit value i...

Страница 102: ...one when no parity bit is required None Check Receive Errors Select whether or not the parity framing and overrun of received characters are checked The parity value of received characters is verified...

Страница 103: ...for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is programmed to accommodate Set the number of stop bits to ma...

Страница 104: ...ine and waits up to the Host Serial Response Time out for the host to assert CTS When the host asserts CTS data is transmitted If after Host Serial Response Time out default the CTS line is still de a...

Страница 105: ...red None Standard RTS CTS Scan the bar code below to select Standard RTS CTS Hardware Handshaking Standard RTS CTS RTS CTS Option 1 When RTS CTS Option 1 is selected the scanner asserts RTS before tra...

Страница 106: ...se Time out default the scanner issues an error indication and discards the data RTS CTS Option 2 RTS CTS Option 3 When Option 3 is selected the scanner asserts RTS prior to any data transmission rega...

Страница 107: ...K NAK When this option is selected after transmitting data the scanner expects either an ACK or NAK response from the host When a NAK is received the scanner transmits the same data again and waits fo...

Страница 108: ...from the host an additional ENQ is not required ACK NAK with ENQ XON XOFF An XOFF character turns the scanner transmission off until the scanner receives an XON character There are two situations for...

Страница 109: ...NAK or CTS before determining that a transmission error has occurred This only applies when in one of the ACK NAK Software Handshaking modes or RTS CTS Hardware Handshaking option This parameter does...

Страница 110: ...Host Serial Response Time out continued High 7 5 Sec Maximum 9 9 Sec RTS Line State This parameter sets the idle state of the Serial Host RTS line Scan a bar code below to select Low RTS or High RTS l...

Страница 111: ...er is enabled the scanner issues a beep when a BEL character is detected on the RS 232 serial line BEL is issued to gain a user s attention to an illegal entry or other important event Beep On BEL Cha...

Страница 112: ...oduct Reference Guide 6 22 Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions Minimum 0 msec Low 25 msec Medium 50 msec High 75 msec Maximu...

Страница 113: ...B or OPOS JPOS is selected this parameter indicates when the scanner should beep and turn on its LED after a decode The Beep LED After CTS Pulse option is not valid when Nixdorf Mode A is selected No...

Страница 114: ...acters is selected all bar code data is send except for unknown characters and no error beeps sound on the scanner When Do Not Send Bar Codes With Unknown Characters is selected bar code data is sent...

Страница 115: ...lues Prefix Suffix Value Full ASCII Code 39 Encode Character ASCII Character 1000 U NUL 1001 A SOH 1002 B STX 1003 C ETX 1004 D EOT 1005 E ENQ 1006 F ACK 1007 G BELL 1008 H BCKSPC 1009 I HORIZ TAB 101...

Страница 116: ...30 D RS 1031 E US 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O 1048 0 0 1049 1 1 1050 2 2 1051 3 3 Table 6 4 RS 232 Prefix Suff...

Страница 117: ...59 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N Table 6 4 RS 232 Prefix Suffix Val...

Страница 118: ...U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i Table 6 4 RS 232 Prefix S...

Страница 119: ...o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S 1127 Undefined 7013 ENTER Table 6 4 RS 232 Prefix Suffix Values Continu...

Страница 120: ...LS 3408 Product Reference Guide 6 30...

Страница 121: ...s 7 7 USB Device Type 7 7 USB Country Keyboard Types Country Codes 7 8 USB Keystroke Delay 7 10 USB CAPS Lock Override 7 11 USB Ignore Unknown Characters 7 12 Emulate Keypad 7 12 USB Keyboard FN 1 Sub...

Страница 122: ...LS 3408 Product Reference Guide 7 2...

Страница 123: ...o a USB host The scanner attaches directly to a USB host or a powered USB hub and is powered by it No additional power supply is required Throughout the programming bar code menus default values are i...

Страница 124: ...M SurePOS terminals Sun IBM and other network computers that support more than one keyboard The following operating systems support the scanner through USB Windows 98 2000 ME XP Mac OS 8 5 and above I...

Страница 125: ...nector in an available port of the IBM SurePOS terminal 3 Ensure that all connections are secure 4 Select the USB device type by scanning the appropriate bar code from the USB Device Type section on p...

Страница 126: ...and miscellaneous default parameters Table 7 1 USB Host Default Table Parameter Default Page Number USB Host Parameters USB Device Type HID Keyboard Emulation 7 7 USB Country Keyboard Types Country C...

Страница 127: ...ters USB Device Type Select the desired USB device type When changing USB Device Types the scanner automatically resets The scanner issues the standard startup beep sequences HID Keyboard Emulation IB...

Страница 128: ...the keyboard type This setting applies only to the USB HID Keyboard Emulation device When changing USB Country Keyboard Types the scanner automatically resets The scanner issues the standard startup...

Страница 129: ...USB Interface 7 9 USB Country Keyboard Types Country Codes continued French Canadian Windows 2000 XP Spanish Windows Italian Windows Swedish Windows UK English Windows...

Страница 130: ...anese Windows ASCII Brazilian Portuguese Windows USB Keystroke Delay This parameter sets the delay in milliseconds between emulated keystrokes Scan a bar code below to increase the delay when hosts re...

Страница 131: ...oard Emulation device When enabled the case of the data is preserved regardless of the state of the caps lock key This setting is always enabled for the Japanese Windows ASCII keyboard type and can no...

Страница 132: ...characters and no error beeps sound When Do Not Send Bar Codes With Unknown Characters is selected bar codes containing at least one unknown character are not sent to the host and an error beep sounds...

Страница 133: ...13 9 to set the Key Category and Key Value Enable USB Keyboard FN 1 Substitution Disable USB Keyboard FN 1 Substitution Function Key Mapping ASCII values under 32 are normally sent as a control key s...

Страница 134: ...f the Caps Lock state is enabled on the keyboard This inversion is done regardless of the current state of the keyboard s Caps Lock state Disable Simulated Caps Lock Enable Simulated Caps Lock Convert...

Страница 135: ...4 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M CTRL M ENTER1 1014 N CTRL N 1015 O CTRL O 1...

Страница 136: ...CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 Table 7 2 USB Prefix Suffix Values Continued Prefix Suffix Value Full ASCI...

Страница 137: ...1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E Table 7 2 USB Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Char acter Keys...

Страница 138: ...081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M Table 7 2 USB Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode...

Страница 139: ...j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u Table 7 2 USB Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Char ac...

Страница 140: ...ys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I Table 7 2 USB Prefix Suffix Values Continued Prefix Suffix Value Full ASCII C...

Страница 141: ...089 ALT Y 2090 ALT Z Table 7 4 USB GUI Key Character Set GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 Note GUI Shift Keys The Apple iMac keyboard has an apple key on either side of t...

Страница 142: ...70 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P Table 7 4 USB GUI Key Character Set Continued GUI Key Keystroke Note GUI Shift Ke...

Страница 143: ...F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 Table 7 4 USB GUI Key Character Set Continued GUI Key Keystroke Note GUI Shift Keys The Apple iMac ke...

Страница 144: ...5 F 15 5016 F16 5017 F 17 5018 F 18 5019 F 19 5020 F 20 5021 F 21 5022 F 22 5023 F 23 5024 F 24 Table 7 6 USB Numeric Keypad Character Set Numeric Keypad Keystroke 6042 6043 6044 undefined 6045 6046 6...

Страница 145: ...ock Table 7 7 USB Extended Keypad Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 PgUp 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 701...

Страница 146: ...S 3408 Product Reference Guide 7 26 7013 Enter 7014 Escape 7015 Up Arrow 7016 Down Arrow 7017 Left Arrow 7018 Right Arrow Table 7 7 USB Extended Keypad Character Set Continued Extended Keypad Keystrok...

Страница 147: ...8 IBM 468X 469X Interface Introduction 8 3 Connecting to an IBM 468X 469X Host 8 4 IBM Default Parameters 8 5 IBM 468X 469X Host Parameters 8 6 Port Address 8 6 Convert Unknown to Code 39 8 7...

Страница 148: ...LS 3408 Product Reference Guide 8 2...

Страница 149: ...duction This chapter provides IBM 468X 469X host information for setting up the scanner Throughout the programming bar code menus default values are indicated with asterisks Disable Convert to Code 39...

Страница 150: ...of the IBM 46XX interface cable to the cable interface port on the scanner See Installing the Interface Cable on page 1 5 2 Connect the other end of the IBM 46XX interface cable to the appropriate por...

Страница 151: ...s provided in the Parameter Descriptions section beginning on page 8 6 See Chapter A Standard Default Parameters for all user preferences hosts symbologies and miscellaneous default parameters Table 8...

Страница 152: ...rameters Port Address This parameter sets the IBM 468X 469X port being used Scanning one of these bar codes enables the RS 485 interface on the scanner Hand held Scanner Emulation Port 9B Non IBM Scan...

Страница 153: ...nterface 8 7 Convert Unknown to Code 39 Scan a bar code below to enable or disable the conversion of unknown bar code type data to Code 39 Convert Unknown to Code 39 Enable Do Not Convert Unknown to C...

Страница 154: ...LS 3408 Product Reference Guide 8 8...

Страница 155: ...tion Interface 9 4 Wand Emulation Default Parameters 9 5 Wand Emulation Host Parameters 9 6 Wand Emulation Host Types 9 6 Leading Margin Quiet Zone 9 7 Polarity 9 8 Ignore Unknown Characters 9 9 Conve...

Страница 156: ...LS 3408 Product Reference Guide 9 2...

Страница 157: ...d The scanner attaches either to an external wand decoder or to a decoder integrated in a portable terminal or Point of Sale POS terminal In this mode the scanner emulates the signal of a digital wand...

Страница 158: ...ular connector of the Wand Emulation interface cable to the cable interface port on the scanner See Installing the Interface Cable on page 1 5 2 Connect the other end of the Wand Emulation interface c...

Страница 159: ...A Standard Default Parameters for all user preferences hosts symbologies and miscellaneous default parameters Table 9 1 Wand Emulation Default Table Parameter Default Page Number Wand Emulation Host...

Страница 160: ...Guide 9 6 Wand Emulation Host Parameters Wand Emulation Host Types Select the Wand Emulation host by scanning one of the bar codes below Symbol OmniLink Interface Controller Symbol PDT Terminal MSI S...

Страница 161: ...e that precedes the first bar of the scan in milliseconds The minimum allowed value is 80 msec and the maximum is 250 msec This parameter is used to accommodate older wand decoders which cannot handle...

Страница 162: ...scanned bar code Different decoders to which this device could be attached are expecting the DBP to be in a certain format The DBP either has the highs represent bars and the lows represent spaces ma...

Страница 163: ...ll bar code data is sent except for unknown characters and no error beeps sound on the scanner When Do Not Send Bar Codes With Unknown Characters is selected bar codes containing at least one unknown...

Страница 164: ...e characters This also allows ADF Formatting to occur If Ignore Unknown Characters is enabled any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a s...

Страница 165: ...set are replaced by a space If this parameter is enabled the data sent to the Wand Interface is encoded in Code 39 Full ASCII This setting requires that the Host be able to interpret Code 39 Full ASC...

Страница 166: ...LS 3408 Product Reference Guide 9 12...

Страница 167: ...er Emulation Host 10 6 Scanner Emulation Host Parameters 10 7 Beep Style 10 7 Parameter Pass Through 10 8 Convert Newer Code Types 10 9 Module Width 10 10 Convert All Bar Codes to Code 39 10 10 Code 3...

Страница 168: ...LS 3408 Product Reference Guide 10 2...

Страница 169: ...Scanner Emulation communication is needed When Scanner Emulation is used the scanner attaches either to an external decoder or to a decoder integrated in a portable terminal or Point of Sale POS termi...

Страница 170: ...tach the modular connector of the Scanner Emulation interface cable to the cable interface port on the scanner See Installing the Interface Cable on page 1 5 2 Connect the other end of the Scanner Emu...

Страница 171: ...parameters Table 10 1 Scanner Emulation Default Table Parameter Default Page Number Scanner Emulation Host Parameters Beep Style Beep on Successful Transmit 10 7 Parameter Pass Through Parameter Proce...

Страница 172: ...LS 3408 Product Reference Guide 10 6 Scanner Emulation Host Scan the bar code below to enable the Scanner Emulation Host Scanner Emulation Host...

Страница 173: ...r beep at the same time The second option is to beep on the scanner s decode This results in a double beep sequence from most decoders since the scanner beeps and the decoder beeps at a different freq...

Страница 174: ...his way customers using Symbol compliant decoders can control the behavior of the entire system by scanning the necessary parameters only once Enabling D 2 of 5 for example can be performed simply by...

Страница 175: ...anner converts these code types to more commonly decodable symbologies as per the following chart Symbologies not listed on this chart are transmitted normally When decoding these code types with this...

Страница 176: ...system this module width can be extended to 50 s through use of this parameter 20 s Module Width 50 s Module Width Convert All Bar Codes to Code 39 Scan the appropriate bar code below to enable or dis...

Страница 177: ...et are replaced by a space If this parameter is enabled the data sent to the Scanner Emulation Host is encoded in Code 39 Full ASCII This setting requires that the Host be able to interpret Code 39 Fu...

Страница 178: ...ul transmission If after a specified amount of time the Decode signal has not been asserted indicating that the attached decoder has not successfully received the bar code data the scanner issues Tran...

Страница 179: ...s not recognize When Ignore Unknown Characters is selected all bar code data is sent except for unknown characters and no error beeps are sounded When Convert Error on Unknown Characters is selected b...

Страница 180: ...8 Product Reference Guide 10 14 Leading Margin Scan a bar code below to select a leading margin duration 1 ms Leading Margin 2 ms Leading Margin 3 ms Leading Margin 5 ms Leading Margin 10 ms Leading M...

Страница 181: ...y decoded the transmitted bar code Some decoders however do not assert the Decode signal to tell the scanner that a decode has occurred In this case the scanner emits Transmit Error beeps to indicate...

Страница 182: ...LS 3408 Product Reference Guide 10 16...

Страница 183: ...11 123 Scan Introduction 11 3 Communication with 123Scan 11 3 123Scan Parameter 11 4...

Страница 184: ...LS 3408 Product Reference Guide 11 2...

Страница 185: ...rather than modifying the host software Scanners can be programmed via PC download or by scanning a sheet of bar codes generated by the utility Scanner programming is saved in a file that can be dist...

Страница 186: ...unicate with the 123Scan program load 123Scan included in the documentation CD ROM onto the PC and scan the bar code below Refer to 123Scan instructions for programming the scanner Scanning this bar c...

Страница 187: ...Enable Disable UPC A 12 10 Enable Disable UPC E 12 10 Enable Disable UPC E1 12 11 Enable Disable EAN 13 12 11 Enable Disable EAN 8 12 12 Enable Disable Bookland EAN 12 12 Decode UPC EAN JAN Supplement...

Страница 188: ...Transmit Code 39 Check Digit 12 30 Code 39 Full ASCII Conversion 12 31 Code 93 12 32 Enable Disable Code 93 12 32 Set Lengths for Code 93 12 32 Code 11 12 34 Code 11 12 34 Set Lengths for Code 11 12 3...

Страница 189: ...12 52 MSI Check Digit Algorithm 12 52 RSS Reduced Space Symbology 12 53 RSS 12 53 RSS Limited 12 53 Convert RSS to UPC EAN 12 54 Redundancy Level 12 55 Redundancy Level 1 12 55 Redundancy Level 2 12 5...

Страница 190: ...LS 3408 Product Reference Guide 12 4...

Страница 191: ...code on page 4 5 If a Synapse or USB cable is not being used a host type must be selected See each host chapter for specific host information Scanning Sequence Examples In most cases only one bar code...

Страница 192: ...logy Default Table Parameter Default Page Number UPC EAN UPC A Enable 12 10 UPC E Enable 12 10 UPC E1 Disable 12 11 EAN 13 JAN 13 Enable 12 11 EAN 8 JAN 8 Enable 12 12 Bookland EAN Disable 12 12 Decod...

Страница 193: ...to Code 32 Disable 12 25 Code 32 Prefix Disable 12 26 Set Length s for Code 39 2 to 55 12 27 Code 39 Check Digit Verification Disable 12 29 Transmit Code 39 Check Digit Disable 12 30 Code 39 Full ASCI...

Страница 194: ...ansmit I 2 of 5 Check Digit Disable 12 42 Convert I 2 of 5 to EAN 13 Disable 12 42 Discrete 2 of 5 D 2 of 5 Discrete 2 of 5 Disable 12 43 Set Lengths for D 2 of 5 12 12 43 Codabar NW 7 Codabar Disable...

Страница 195: ...sable 12 53 RSS Limited Disable 12 53 RSS Expanded Disable 12 54 Convert RSS to UPC EAN Disable 12 54 Symbology Specific Security Levels Redundancy Level 1 12 55 Security Levels 0 12 57 Bi directional...

Страница 196: ...10 UPC EAN Enable Disable UPC A To enable or disable UPC A scan the appropriate bar code below Enable UPC A Disable UPC A Enable Disable UPC E To enable or disable UPC E scan the appropriate bar code...

Страница 197: ...ble or disable UPC E1 scan the appropriate bar code below UPC E1 is not a UCC Uniform Code Council approved symbology Enable UPC E1 Disable UPC E1 Enable Disable EAN 13 To enable or disable EAN 13 sca...

Страница 198: ...le EAN 8 To enable or disable EAN 8 scan the appropriate bar code below Enable EAN 8 JAN 8 Disable EAN 8 JAN 8 Enable Disable Bookland EAN To enable or disable Bookland EAN scan the appropriate bar co...

Страница 199: ...only EAN13 bar codes starting with a 378 or 379 prefix to be delayed by the supplemental search process All other UPC EAN bar codes are exempted from the search and are reported instantly upon their...

Страница 200: ...erence Guide 12 14 Decode UPC EAN JAN Supplementals continued Ignore Supplementals Autodiscriminate UPC EAN JAN Supplementals Enable 378 379 Supplemental Mode Enable 978 Supplemental Mode Enable Smart...

Страница 201: ...code redundancy value Next scan two numeric bar codes beginning on page D 1 in Chapter D Numeric Bar Codes Single digit numbers must have a leading zero In case of an error or to change the selection...

Страница 202: ...LS 3408 Product Reference Guide 12 16 UPC E Check Digit Transmit UPC E Check Digit Do Not Transmit UPC E Check Digit UPC E1 Check Digit Transmit UPC E1 Check Digit Do Not Transmit UPC E1 Check Digit...

Страница 203: ...given for transmitting UPC A preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Select the appropriate option...

Страница 204: ...ptions are given for transmitting UPC E preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Select the appropria...

Страница 205: ...given for transmitting UPC E1 preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Select the appropriate option...

Страница 206: ...onverted to UPC A format before transmission After conversion the data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit When disabled UPC E decoded data is...

Страница 207: ...ormat before transmission After conversion the data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit When disabled UPC E1 decoded data is transmitted as UP...

Страница 208: ...decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols When disabled EAN 8 symbols are transmitted as is Enable EAN JAN Zero Extend Disable EAN JAN Zero Extend Code 128 Enable Disa...

Страница 209: ...AN 128 To enable or disable UCC EAN 128 scan the appropriate bar code below Enable UCC EAN 128 Disable UCC EAN 128 Enable Disable ISBT 128 To enable or disable ISBT 128 scan the appropriate bar code b...

Страница 210: ...ble Disable Trioptic Code 39 Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges Trioptic Code 39 symbols always contain six characters To enable or disable Triopt...

Страница 211: ...39 used by the Italian pharmaceutical industry Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 Code 39 must be enabled in order for this parameter to function Co...

Страница 212: ...32 Prefix Scan the appropriate bar code below to enable or disable adding the prefix character A to all Code 32 bar codes Convert Code 39 to Code 32 must be enabled for this parameter to function Ena...

Страница 213: ...n Chapter D Numeric Bar Codes For example to decode only Code 39 symbols with 14 characters scan Code 39 One Discrete Length then scan 1 followed by 4 In case of an error or to change the selection sc...

Страница 214: ...de 39 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero In case of an error or to change the selection scan Cancel on page D 7 Code 39 Length Wit...

Страница 215: ...ymbols to verify that the data complies with specified check digit algorithm Only those Code 39 symbols which include a modulo 43 check digit are decoded when this feature is enabled This feature shou...

Страница 216: ...9 Check Digit Scan a bar code below to transmit Code 39 data with or without the check digit Transmit Code 39 Check Digit Enable Do Not Transmit Code 39 Check Digit Disable Code 39 Check Digit Verific...

Страница 217: ...ing of Code 39 characters to ASCII values Enable Code 39 Full ASCII Disable Code 39 Full ASCII Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously Code 39 Full ASCII to Full ASCII...

Страница 218: ...ode 93 may be set for any length one or two discrete lengths or lengths within a specific range One Discrete Length This option allows scanner to decode only those Code 93 symbols containing a selecte...

Страница 219: ...D 7 Code 93 Two Discrete Lengths Length Within Range This option allows the scanner to decode a Code 93 symbol with a specific length range The length range is selected from numeric bar codes beginnin...

Страница 220: ...y be set for any length one or two discrete lengths or lengths within a specific range One Discrete Length This option allows the scanner to decode only those Code 11 symbols containing a selected len...

Страница 221: ...D 7 Code 11 Two Discrete Lengths Length Within Range This option allows the scanner to decode a Code 11 symbol with a specific length range The length range is selected from numeric bar codes beginni...

Страница 222: ...plies with the specified check digit algorithm This selects the check digit mechanism for the decoded Code 11 bar code The options are to check for one check digit check for two check digits or disabl...

Страница 223: ...gits This feature selects whether or not to transmit the Code 11 check digit s Transmit Code 11 Check Digit s Enable Do Not Transmit Code 11 Check Digit s Disable Code 11 Check Digit Verification must...

Страница 224: ...characters including check digit s the code contains Lengths for I 2 of 5 may be set for any length one or two discrete lengths or lengths within a specific range One Discrete Length This option allow...

Страница 225: ...2 1 and then 4 In case of an error or to change the selection scan Cancel on page D 7 I 2 of 5 Two Discrete Lengths Length Within Range This option allows the scanner to decode an I 2 of 5 symbol with...

Страница 226: ...r capability Due to the construction of the I 2 of 5 symbology it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan yielding less data than is actual...

Страница 227: ...ure is enabled the scanner checks the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification USS or the Optical Product Code Council OP...

Страница 228: ...Disable Convert I 2 of 5 to EAN 13 This parameter converts a 14 character I 2 of 5 code into EAN 13 and transmits to the host as EAN 13 In order to accomplish this the I 2 of 5 code must be enabled an...

Страница 229: ...Lengths for D 2 of 5 may be set for any length one or two discrete lengths or lengths within a specific range One Discrete Length This option allows the scanner to decode only those D 2 of 5 symbols...

Страница 230: ...scan 0 2 1 and then 4 In case of an error or to change the selection scan Cancel on page D 7 D 2 of 5 Two Discrete Lengths Length Within Range This option allows the scanner to decode an D 2 of 5 sym...

Страница 231: ...for a scan line covering only a portion of the code to be interpreted as a complete scan yielding less data than is actually encoded in the bar code To prevent this from happening it is recommended th...

Страница 232: ...r Codes For example to decode only Codabar symbols with 14 characters scan Codabar One Discrete Length then scan 1 followed by 4 In case of an error or to change the selection scan Cancel on page D 7...

Страница 233: ...Codes For example to decode Codabar symbols containing between 4 and 12 characters first scan Codabar Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leadin...

Страница 234: ...Codabar symbol Enable this feature if the host system requires this data format Symbol length does not include start and stop characters Enable CLSI Editing Disable CLSI Editing NOTIS Editing When en...

Страница 235: ...for any length one or two discrete lengths or lengths within a specific range One Discrete Length This option allows the scanner to decode only those MSI symbols containing a selected length Lengths a...

Страница 236: ...scan 0 2 1 and then 4 In case of an error or to change the selection scan Cancel on page D 7 MSI Two Discrete Lengths Length Within Range This option allows the scanner to decode an MSI symbol with a...

Страница 237: ...ed in the bar code To prevent this from happening it is recommended that specific lengths MSI One Discrete Length Two Discrete Lengths be selected for MSI applications MSI Any Length MSI Check Digits...

Страница 238: ...thout the check digit Transmit MSI Check Digit s Enable Do Not Transmit MSI Check Digit s Disable MSI Check Digit Algorithm Two algorithms are possible for the verification of the second MSI check dig...

Страница 239: ...RSS are RSS 14 RSS Expanded and RSS Limited The limited and expanded versions have stacked variants Scan the appropriate bar code below to enable or disable each variant of RSS RSS 14 Enable RSS 14 D...

Страница 240: ...encoding a single zero as the first digit have the leading 010 stripped and the bar code reported as EAN 13 Bar codes beginning with two or more zeros but not six zeros have the leading 0100 stripped...

Страница 241: ...dundancy level appropriate for the bar code quality Redundancy Level 1 The following code types must be successfully read twice before being decoded Redundancy Level 1 Redundancy Level 2 The following...

Страница 242: ...lowing codes must be read three times Redundancy Level 3 Redundancy Level 4 The following code types must be successfully read three times before being decoded Redundancy Level 4 Code Type Code Length...

Страница 243: ...of security necessary for any given application Security Level 0 This is the default setting which allows the scanner to operate fastest while providing sufficient security in decoding in spec UPC EAN...

Страница 244: ...curity Level 3 If Security Level 2 has been tried and the scanner is still misdecoding select this security level Be advised selecting this option is an extreme measure against misdecoding severely ou...

Страница 245: ...dundancy is used for added security to linear code type security levels When enabled a bar code must be successfully scanned in both directions forward and reverse before reporting a good decode Enabl...

Страница 246: ...LS 3408 Product Reference Guide 12 60...

Страница 247: ...While Scanning 13 4 Miscellaneous Default Parameters 13 4 Miscellaneous Scanner Parameters 13 5 Transmit Code ID Character 13 5 Scan Angle 13 6 Prefix Suffix Values 13 6 Scan Data Transmission Format...

Страница 248: ...LS 3408 Product Reference Guide 13 2...

Страница 249: ...Chapter 14 Advanced Data Formatting for customizing data for transmission to the host device Before programming follow the instructions in Chapter 1 Getting Started The scanner is shipped with the set...

Страница 250: ...canner options parameters To change any option scan the appropriate bar code s provided in the Miscellaneous Scanner Parameters section beginning on page 13 5 See Chapter A Standard Default Parameters...

Страница 251: ...more than one code type In addition to any single character prefix already selected the Code ID character is inserted between the prefix and the decoded symbol The user may select no Code ID characte...

Страница 252: ...lues A prefix suffix may be appended to scan data for use in data editing These values are set by scanning a four digit number i e four bar codes that corresponds to key codes for various terminals Fo...

Страница 253: ...s Data As Is DATA SUFFIX PREFIX DATA PREFIX DATA SUFFIX When a selection is made scan the Enter bar code on page 13 8 In case of a mistake scan the Data Format Cancel bar code on page 13 8 To program...

Страница 254: ...LS 3408 Product Reference Guide 13 8 Scan Data Transmission Format continued PREFIX DATA PREFIX DATA SUFFIX Enter Data Format Cancel...

Страница 255: ...nterface Enter the 4 digit ASCII Value by scanning each digit in the Numeric Bar Codes on page D 1 3 To correct an error or change the selection scan CANCEL To enable FN1 Substitution for Wedge scan t...

Страница 256: ...connection should be used In all other cases where the cable is used the default setting is recommended Should the user want to disconnect and reconnect the scanner from a Synapse cable that is connec...

Страница 257: ...ar Code Menu Example 14 4 Rule 1 The Code 128 Scanning Rule 14 5 Rule 2 The UPC Scanning Rule 14 5 Alternate Rule Sets 14 6 Rules Hierarchy in Bar Codes 14 7 Default Rules 14 8 Special Commands 14 9 P...

Страница 258: ...2 Actions 14 27 Send Data 14 27 Setup Field s 14 31 Modify Data 14 38 Pad Data with Spaces 14 40 Pad Data with Zeros 14 46 Beeps 14 52 Send Keystroke Control Characters and Keyboard Characters 14 53 S...

Страница 259: ...se rules perform detailed actions when the data meets certain criteria One rule may consist of single or multiple criteria applied to single or multiple actions For instance a data formatting rule cou...

Страница 260: ...n Erase Actions and Start Again Erase Previously Saved Rule etc Criteria actions and entire rules may be erased by scanning the appropriate bar code see page 14 10 Use the Beeper Definitions on page 2...

Страница 261: ...w Rule 14 9 High High 2 Code 128 14 12 High High 3 Send next 5 characters 14 28 High High 4 Send CTRL M 14 55 High High 5 Send next 5 characters 14 28 High High 6 Send CTRL P 14 56 High High 7 Send ne...

Страница 262: ...ale send only the following 24 class key 56712437 stock key and the cashier keys the price manually To implement this first enter an ADF rule that applies to the normal situation This rule may look li...

Страница 263: ...within the rules it is possible to enable or disable them by scanning the appropriate bar codes on 14 11 Rules Hierarchy in Bar Codes The order of programming individual rules is important The most g...

Страница 264: ...uffix programming in the parameter Scan Data Transmission Format These rules reside in the same rule list as ADF Rules so the order of their creation is also important Default Rules Every unit has a d...

Страница 265: ...s and are measured in 0 1 second intervals For example scanning bar codes 0 and 1 inserts a 0 1 second pause 0 and 5 gives a 0 5 second delay Numeric bar codes begin on page D 1 in Chapter D Numeric B...

Страница 266: ...Use these bar codes to erase criteria actions or rules Quit Entering Rules Scan this bar code to quit entering rules Quit Entering Rules Erase Criteria And Start Again Erase Actions And Start Again E...

Страница 267: ...Advanced Data Formatting 14 11 Disable Rule Set Use these bar codes to disable rule sets Disable Rule Set 1 Disable Rule Set 2 Disable Rule Set 3 Disable Rule Set 4 Disable All Rule Sets...

Страница 268: ...o be affected All selected codes must be scanned in succession prior to selecting other criteria If a code type is not selected all code types are affected Scan the bar codes for all code types desire...

Страница 269: ...Advanced Data Formatting 14 13 Code Types continued D 2 OF 5 IATA 2 OF 5 I 2 OF 5 Code 93 UPC A UPC E...

Страница 270: ...LS 3408 Product Reference Guide 14 14 Code Types continued EAN 8 EAN 13 MSI UCC EAN 128 UPC E1 Bookland EAN...

Страница 271: ...Advanced Data Formatting 14 15 Code Types continued Trioptic Code 39 Code 11 EAN 128...

Страница 272: ...selected code type must contain If a code length is not selected selected code types of any length are affected Scan these bar codes to define the number of characters the selected code types must con...

Страница 273: ...Advanced Data Formatting 14 17 Code Lengths continued 5 Characters 6 Characters 7 Characters 8 Characters 9Characters 10 Characters...

Страница 274: ...LS 3408 Product Reference Guide 14 18 Code Lengths continued 11Characters 12 Characters 13Characters 14 Characters 15Characters 16 Characters...

Страница 275: ...Advanced Data Formatting 14 19 Code Lengths continued 17Characters 18 Characters 19Characters 20 Characters 21Characters 22 Characters...

Страница 276: ...LS 3408 Product Reference Guide 14 20 Code Lengths continued 23Characters 24 Characters 25Characters 26 Characters 27Characters 28 Characters...

Страница 277: ...Advanced Data Formatting 14 21 Code Lengths continued 29Characters 30 Characters...

Страница 278: ...4 features Specific String at Start Specific String Any Location Any Message OK Rule Belongs to Set Specific String at Start Scan this bar code then scan the bar codes representing the desired charact...

Страница 279: ...otal of 8 on the Alphanumeric Keyboard on page 14 105 followed by the End of Message bar code on page 14 116 After scanning the following bar code 1 Enter a location using the Numeric Keypad on page 2...

Страница 280: ...LS 3408 Product Reference Guide 14 24 Numeric Keypad Bar codes on this page should not be confused with those on the alphanumeric keyboard 0 1 2 3 4 5...

Страница 281: ...Advanced Data Formatting 14 25 Numeric Keypad continued 6 7 8 9 Cancel...

Страница 282: ...a rule belongs to There are four possible rule sets See Alternate Rule Sets on page 14 6 for more information about rule sets Scan a bar code below to select which set a rule belongs to Rule Belongs T...

Страница 283: ...ta up to a specific character selected from the Alphanumeric Keyboard on page 14 105 or send the next N characters N any number from 1 to 254 selected from the Alphanumeric Keyboard Use these bar code...

Страница 284: ...LS 3408 Product Reference Guide 14 28 Send Data continued Send Next 4 Characters Send Next 5Characters Send Next 6Characters Send Next 7Characters Send Next 8 Characters Send Next 9 Characters...

Страница 285: ...Advanced Data Formatting 14 29 Send Data continued Send Next 10 Characters Send Next 11Characters Send Next 12Characters Send Next 13Characters Send Next 14 Characters Send Next 15 Characters...

Страница 286: ...LS 3408 Product Reference Guide 14 30 Send Data continued Send Next 16 Characters Send Next 17Characters Send Next 18Characters Send Next 19Characters Send Next 20 Characters...

Страница 287: ...ves the cursor past all sequential occurrences of a selected character For example if the selected character is A then the cursor moves past A AA AAA etc Scan the Move Cursor Past Character bar code o...

Страница 288: ...hanumeric Keyboard beginning on page 14 105 If there is no match when the rule is interpreted and the rule fails the next rule is checked Send Pause Scan the bar code below to insert a pause in the tr...

Страница 289: ...matting 14 33 Skip Ahead Use the following bar codes to skip ahead characters Skip Ahead 1 Character Skip Ahead 2 Characters Skip Ahead 3Characters Skip Ahead 4Characters Skip Ahead 5 Characters Skip...

Страница 290: ...LS 3408 Product Reference Guide 14 34 Skip Ahead continued Skip Ahead 7Characters Skip Ahead 8Characters Skip Ahead 9Characters Skip Ahead 10Characters...

Страница 291: ...Formatting 14 35 Skip Back Use the following bar codes to skip back characters Skip Back 1 Character Skip Back 2 Characters Skip Back 3Characters Skip Back 4Characters Skip Back 5 Characters Skip Bac...

Страница 292: ...LS 3408 Product Reference Guide 14 36 Skip Back continued Skip Back 7Characters Skip Back 8Characters Skip Back 9Characters Skip Back 10Characters...

Страница 293: ...Advanced Data Formatting 14 37 Send Preset Value Use these bar codes to send preset values These values must be set using the Scan Prefix and Scan Suffix bar codes on page 13 6 Send Prefix Send Suffix...

Страница 294: ...ded to the first send and the next send is unaffected by the padding These options do not apply to the Send Keystroke or Send Preset Value options Remove All Spaces To remove all spaces in the send co...

Страница 295: ...Formatting 14 39 Modify Data Continued Remove Leading Zeros Scan this bar code to remove all leading zeros Remove Leading Zeros Stop Zero Removal Scan this bar code to disable the removal of zeros Sto...

Страница 296: ...ad Data with Spaces To pad data to the left scan the bar code containing the desired number of spaces This parameter is activated by Send commands Pad Spaces To Length 1 Pad Spaces To Length 2 Pad Spa...

Страница 297: ...Advanced Data Formatting 14 41 Pad Data with Spaces continued Pad Spaces To Length 5 Pad Spaces To Length 6 Pad Spaces To Length 7 Pad Spaces To Length 8 Pad Spaces To Length 9 Pad Spaces To Length 10...

Страница 298: ...8 Product Reference Guide 14 42 Pad Data with Spaces continued Pad Spaces To Length 11 Pad Spaces To Length 12 Pad Spaces To Length 13 Pad Spaces To Length 14 Pad Spaces To Length 15 Pad Spaces To Len...

Страница 299: ...anced Data Formatting 14 43 Pad Data with Spaces continued Pad Spaces To Length 17 Pad Spaces To Length 18 Pad Spaces To Length 19 Pad Spaces To Length 20 Pad Spaces To Length 21 Pad Spaces To Length...

Страница 300: ...8 Product Reference Guide 14 44 Pad Data with Spaces continued Pad Spaces To Length 23 Pad Spaces To Length 24 Pad Spaces To Length 25 Pad Spaces To Length 26 Pad Spaces To Length 27 Pad Spaces To Len...

Страница 301: ...Advanced Data Formatting 14 45 Pad Data with Spaces continued Pad Spaces To Length 29 Pad Spaces To Length 30 Stop Pad Spaces...

Страница 302: ...6 Pad Data with Zeros To pad data to the left scan the bar code containing the desired number of zeros This parameter is activated by Send commands Pad Zeros To Length 1 Pad Zeros To Length 2 Pad Zero...

Страница 303: ...Advanced Data Formatting 14 47 Pad Data with Zeros continued Pad Zeros To Length 5 Pad Zeros To Length 6 Pad Zeros To Length 7 Pad Zeros To Length 8 Pad Zeros To Length 9 Pad Zeros To Length 10...

Страница 304: ...3408 Product Reference Guide 14 48 Pad Data with Zeros continued Pad Zeros To Length 11 Pad Zeros To Length 12 Pad Zeros To Length 13 Pad Zeros To Length 14 Pad Zeros To Length 15 Pad Zeros To Length...

Страница 305: ...Advanced Data Formatting 14 49 Pad Data with Zeros continued Pad Zeros To Length 17 Pad Zeros To Length 18 Pad Zeros To Length 19 Pad Zeros To Length 20 Pad Zeros To Length 21 Pad Zeros To Length 22...

Страница 306: ...3408 Product Reference Guide 14 50 Pad Data with Zeros continued Pad Zeros To Length 23 Pad Zeros To Length 24 Pad Zeros To Length 25 Pad Zeros To Length 26 Pad Zeros To Length 27 Pad Zeros To Length...

Страница 307: ...Advanced Data Formatting 14 51 Pad Data with Zeros continued Pad Zeros To Length 29 Pad Zeros To Length 30 Stop Pad Zeros...

Страница 308: ...LS 3408 Product Reference Guide 14 52 Beeps Select a beep sequence for each ADF rule Beep Once Beep Twice Beep Three Times...

Страница 309: ...ata Formatting 14 53 Send Keystroke Control Characters and Keyboard Characters Control Characters Scan the Send __ bar code for the desired keystroke Send Control 2 Send Control A Send Control B Send...

Страница 310: ...LS 3408 Product Reference Guide 14 54 Control Characters continued Send Control D Send Control E Send Control F Send Control G Send Control H Send Control I...

Страница 311: ...Advanced Data Formatting 14 55 Control Characters continued Send Control J Send Control K Send Control L Send Control M Send Control N Send Control O...

Страница 312: ...LS 3408 Product Reference Guide 14 56 Control Characters continued Send Control P Send Control Q Send Control R Send Control S Send Control T Send Control U...

Страница 313: ...Advanced Data Formatting 14 57 Control Characters continued Send Control V Send Control W Send Control X Send Control Y Send Control Z Send Control...

Страница 314: ...LS 3408 Product Reference Guide 14 58 Control Characters continued Send Control Send Control Send Control 6 Send Control...

Страница 315: ...Advanced Data Formatting 14 59 Keyboard Characters Scan the Send __ bar code for the desired keyboard characters Send Space Send Send Send Send Send...

Страница 316: ...LS 3408 Product Reference Guide 14 60 Keyboard Characters continued Send Send Send Send Send Send...

Страница 317: ...Advanced Data Formatting 14 61 Keyboard Characters continued Send Send Send Send Send 0 Send 1...

Страница 318: ...LS 3408 Product Reference Guide 14 62 Keyboard Characters continued Send 2 Send 3 Send 4 Send 5 Send 6 Send 7...

Страница 319: ...Advanced Data Formatting 14 63 Keyboard Characters continued Send 8 Send 9 Send Send Send Send...

Страница 320: ...LS 3408 Product Reference Guide 14 64 Keyboard Characters continued Send Send Send Send A Send B Send C...

Страница 321: ...Advanced Data Formatting 14 65 Keyboard Characters continued Send D Send E Send F Send G Send H Send I...

Страница 322: ...LS 3408 Product Reference Guide 14 66 Keyboard Characters continued Send J Send K Send L Send M Send N Send O...

Страница 323: ...Advanced Data Formatting 14 67 Keyboard Characters continued Send P Send Q Send R Send S Send T Send U...

Страница 324: ...LS 3408 Product Reference Guide 14 68 Keyboard Characters continued Send V Send W Send X Send Y Send Z Send...

Страница 325: ...Advanced Data Formatting 14 69 Keyboard Characters continued Send Send Send Send _ Send Send a...

Страница 326: ...LS 3408 Product Reference Guide 14 70 Keyboard Characters continued Send b Send c Send d Send e Send f Send g...

Страница 327: ...Advanced Data Formatting 14 71 Keyboard Characters continued Send h Send i Send j Send k Send l Send m...

Страница 328: ...LS 3408 Product Reference Guide 14 72 Keyboard Characters continued Send n Send o Send p Send q Send r Send s...

Страница 329: ...Advanced Data Formatting 14 73 Keyboard Characters continued Send t Send u Send v Send w Send x Send y...

Страница 330: ...LS 3408 Product Reference Guide 14 74 Keyboard Characters continued Send z Send Send Send Send...

Страница 331: ...Advanced Data Formatting 14 75 Send ALT Characters Send Alt 2 Send Alt A Send Alt B Send Alt C Send Alt D Send Alt E...

Страница 332: ...LS 3408 Product Reference Guide 14 76 Send ALT Characters continued Send Alt F Send Alt G Send Alt H Send Alt I Send Alt J Send Alt K...

Страница 333: ...Advanced Data Formatting 14 77 Send ALT Characters continued Send Alt L Send Alt M Send Alt N Send Alt O Send Alt P Send Alt Q...

Страница 334: ...LS 3408 Product Reference Guide 14 78 Send ALT Characters continued Send Alt R Send Alt S Send Alt T Send Alt U Send Alt V Send Alt W...

Страница 335: ...Advanced Data Formatting 14 79 Send ALT Characters continued Send Alt X Send Alt Y Send Alt Z Send Alt Send Alt Send Alt...

Страница 336: ...LS 3408 Product Reference Guide 14 80 Send ALT Characters continued Send Alt 6 Send Alt...

Страница 337: ...Advanced Data Formatting 14 81 Send Keypad Characters Send Keypad Send Keypad Send Keypad Send Keypad Send Keypad Send Keypad 0...

Страница 338: ...LS 3408 Product Reference Guide 14 82 Send Keypad Characters continued Send Keypad 1 Send Keypad 2 Send Keypad 3 Send Keypad 4 Send Keypad 5 Send Keypad 6...

Страница 339: ...Advanced Data Formatting 14 83 Send Keypad Characters continued Send Keypad 7 Send Keypad 8 Send Keypad 9 Send Keypad Enter Send Keypad Numlock NUM LOCK Send Break Key...

Страница 340: ...LS 3408 Product Reference Guide 14 84 Send Keypad Characters continued Send Delete Key Send Page Up Key Send End Key Send Page Down Key Send Pause Key Send Scroll Lock Key...

Страница 341: ...Advanced Data Formatting 14 85 Send Keypad Characters continued Send Backspace Key Send Tab Key Send Print Screen Key Send Insert Key Send Home Key Send Enter Key...

Страница 342: ...LS 3408 Product Reference Guide 14 86 Send Keypad Characters continued Send Escape Key Send Up Arrow Key Send Down Arrow Key Send Left Arrow Key Send Right Arrow Key...

Страница 343: ...Advanced Data Formatting 14 87 Send Function Key Send F1 Key Send F2 Key Send F3 Key Send F4 Key Send F5 Key Send F6 Key...

Страница 344: ...LS 3408 Product Reference Guide 14 88 Send Function Key continued Send F7 Key Send F8 Key Send F9 Key Send F10 Key Send F11 Key Send F12 Key...

Страница 345: ...Advanced Data Formatting 14 89 Send Function Key continued Send F13 Key Send F14 Key Send F15 Key Send F16 Key Send F17 Key Send F18 Key...

Страница 346: ...LS 3408 Product Reference Guide 14 90 Send Function Key continued Send F19 Key Send F20 Key Send F21 Key Send F22 Key Send F23 Key Send F24 Key...

Страница 347: ...Advanced Data Formatting 14 91 Send Function Key continued Send PF1 Key Send PF2 Key Send PF3 Key Send PF4 Key Send PF5 Key Send PF6 Key...

Страница 348: ...LS 3408 Product Reference Guide 14 92 Send Function Key continued Send PF7 Key Send PF8 Key Send PF9 Key Send PF10 Key Send PF11 Key Send PF12 Key...

Страница 349: ...Advanced Data Formatting 14 93 Send Function Key continued Send PF13 Key Send PF14 Key Send PF15 Key Send PF16 Key Send PF17 Key Send PF18 Key...

Страница 350: ...LS 3408 Product Reference Guide 14 94 Send Function Key continued Send PF19 Key Send PF20 Key Send PF21 Key Send PF22 Key Send PF23 Key Send PF24 Key...

Страница 351: ...Advanced Data Formatting 14 95 Send Function Key continued Send PF25 Key Send PF26 Key Send PF27 Key Send PF28 Key Send PF29 Key Send PF30 Key...

Страница 352: ...rol Key Send Right Control Key Send Graphic User Interface GUI Characters The Send Graphic User Interface Character actions tap the specified key while holding the System Dependent Graphic User Interf...

Страница 353: ...Advanced Data Formatting 14 97 Send Graphic User Interface GUI Characters continued Send GUI 4 Send GUI 5 Send GUI 6 Send GUI 7 Send GUI 8 Send GUI 9...

Страница 354: ...LS 3408 Product Reference Guide 14 98 Send Graphic User Interface GUI Characters continued Send GUI A Send GUI B Send GUI C Send GUI D Send GUI E Send GUI F...

Страница 355: ...Advanced Data Formatting 14 99 Send Graphic User Interface GUI Characters continued Send GUI G Send GUI H Send GUI I Send GUI J Send GUI K Send GUI L...

Страница 356: ...LS 3408 Product Reference Guide 14 100 Send Graphic User Interface GUI Characters continued Send GUI M Send GUI N Send GUI O Send GUI P Send GUI Q Send GUI R...

Страница 357: ...Advanced Data Formatting 14 101 Send Graphic User Interface GUI Characters continued Send GUI S Send GUI T Send GUI U Send GUI V Send GUI W Send GUI X...

Страница 358: ...LS 3408 Product Reference Guide 14 102 Send Graphic User Interface GUI Characters continued Send GUI Y Send GUI Z...

Страница 359: ...Advanced Data Formatting 14 103 Turn On Off Rule Sets Use these bar codes to turn rule sets on and off Turn On Rule Set 1 Turn On Rule Set 2 Turn On Rule Set 3 Turn On Rule Set 4...

Страница 360: ...LS 3408 Product Reference Guide 14 104 Turn On Off Rule Sets continued Use these bar codes to turn rule sets on and off Turn Off Rule Set 1 Turn Off Rule Set 2 Turn Off Rule Set 3 Turn Off Rule Set 4...

Страница 361: ...Advanced Data Formatting 14 105 Alphanumeric Keyboard Space...

Страница 362: ...LS 3408 Product Reference Guide 14 106 Alphanumeric Keyboard continued Dash...

Страница 363: ...Advanced Data Formatting 14 107 Alphanumeric Keyboard continued...

Страница 364: ...LS 3408 Product Reference Guide 14 108 Alphanumeric Keyboard continued...

Страница 365: ...Advanced Data Formatting 14 109 Alphanumeric Keyboard continued Alphanumeric Keyboard continued Bar codes on this page should not be confused with those on the numeric keypad _ Underscore...

Страница 366: ...LS 3408 Product Reference Guide 14 110 0 1 2 3...

Страница 367: ...Advanced Data Formatting 14 111 Alphanumeric Keyboard continued 4 5 6 7 8 9...

Страница 368: ...LS 3408 Product Reference Guide 14 112 Alphanumeric Keyboard continued A B C D E F...

Страница 369: ...Advanced Data Formatting 14 113 Alphanumeric Keyboard continued G H I J K L...

Страница 370: ...LS 3408 Product Reference Guide 14 114 Alphanumeric Keyboard continued M N O P Q R...

Страница 371: ...Advanced Data Formatting 14 115 Alphanumeric Keyboard continued S T U V W X...

Страница 372: ...LS 3408 Product Reference Guide 14 116 Alphanumeric Keyboard continued Y Z Cancel End of Message...

Страница 373: ...Advanced Data Formatting 14 117 Alphanumeric Keyboard continued a b c d e f...

Страница 374: ...LS 3408 Product Reference Guide 14 118 Alphanumeric Keyboard continued g h i j k l...

Страница 375: ...Advanced Data Formatting 14 119 Alphanumeric Keyboard continued m n o p q r...

Страница 376: ...LS 3408 Product Reference Guide 14 120 Alphanumeric Keyboard continued s t u v w x...

Страница 377: ...Advanced Data Formatting 14 121 Alphanumeric Keyboard continued y z...

Страница 378: ...LS 3408 Product Reference Guide 14 122...

Страница 379: ...A Standard Default Parameters...

Страница 380: ...LS 3408 Product Reference Guide A 2...

Страница 381: ...ion 0 0 sec 4 10 Keyboard Wedge Host Parameters Keyboard Wedge Host Type IBM PC AT IBM PC Compatibles1 5 6 Keyboard Wedge Country Types Country Codes North American 5 7 Ignore Unknown Characters Enabl...

Страница 382: ...shaking None 6 14 Software Handshaking None 6 17 Host Serial Response Time out Minimum 2 Sec 6 19 RTS Line State Host Low RTS 6 20 Beep on BEL Disable 6 21 Intercharacter Delay Minimum 0 msec 6 22 Nix...

Страница 383: ...ersion 7 14 IBM 468X 469X Host Parameters Port Address None Selected 8 6 Convert Unknown to Code 39 Disable 8 7 Wand Emulation Host Parameters Wand Emulation Host Types Symbol OmniLink Interface Contr...

Страница 384: ...11 Transmission Timeout 3 seconds 10 12 Ignore Unknown Characters Ignore Unknown Characters 10 13 Leading Margin 2 ms 10 14 Check for Decode LED Check for Decode LED 10 15 123Scan Configuration Tool...

Страница 385: ...acter 12 18 UPC E1 Preamble System Character 12 19 Convert UPC E to A Disable 12 20 Convert UPC E1 to A Disable 12 21 EAN 8 JAN 8 Extend Disable 12 22 Code 128 Code 128 Enable 12 22 UCC EAN 128 Enable...

Страница 386: ...de 11 Check Digit Verification One Check Digit 12 36 Transmit Code 11 Check Digits Disable 12 37 Interleaved 2 of 5 I 2 of 5 Interleaved 2 of 5 I 2 of 5 Enable 12 38 Set Lengths for Interleaved 2 of 5...

Страница 387: ...eck Digits One 12 51 Transmit MSI Check Digit s Disable 12 52 MSI Check Digit Algorithm Mod 10 Mod 10 12 52 RSS Reduced Space Symbology RSS 14 Disable 12 53 RSS Limited Disable 12 53 RSS Expanded Disa...

Страница 388: ...LF 13 6 Suffix Value 7013 CR LF 13 6 Scan Data Transmission Format Data As Is 13 7 FN1 Substitution Values Set FN1 Substitution Value 13 9 Transmit No Read Message Disable No Read 13 9 Synapse Interf...

Страница 389: ...B Programming Reference Symbol Code Identifiers B 3 AIM Code Identifiers B 4...

Страница 390: ...LS 3408 Product Reference Guide B 2...

Страница 391: ...l Code Characters Code Character Code Type A UPC A UPC E UPC E1 EAN 8 EAN 13 B Code 39 Code 32 C Codabar D Code 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5 or Discrete 2 of 5 IATA H Code 11 J...

Страница 392: ...Character ASCII 93 c Code Character see Table 2 2 m Modifier Character see Table B 3 Table 2 2 Aim Code Characters Code Character Code Type A Code 39 Code 39 Full ASCII Code 32 C Code 128 E UPC EAN e...

Страница 393: ...ways transmit 0 Example A Trioptic bar code 412356 is transmitted as X0412356 Code 128 0 Standard data packet no Function code 1 in first symbol position 1 Function code 1 in first symbol character po...

Страница 394: ...e format which is 13 digits for UPC A and UPC E not including supplemental data 1 Two digit supplement data only 2 Five digit supplement data only 4 EAN 8 data packet Example A UPC A bar code 01234567...

Страница 395: ...C Sample Bar Codes UPC A C 3 UPC E C 3 UPC E1 C 3 EAN 13 C 4 EAN 8 C 4 Code 39 C 4 Trioptic Code 39 C 5 Code 93 C 5 Code 11 C 5 Codabar C 6 MSI C 6 Interleaved 2 of 5 C 6...

Страница 396: ...LS 3408 Product Reference Guide C 2...

Страница 397: ...Sample Bar Codes C 3 UPC A UPC E UPC E1 0 12345 67890 5 0 123456 5 1 123456 2...

Страница 398: ...LS 3408 Product Reference Guide C 4 EAN 13 EAN 8 Code 39 3 456789 012340 1234 5670 123ABC...

Страница 399: ...Sample Bar Codes C 5 Trioptic Code 39 Code 93 Code 11 456123 12345ABCDE 1234567890...

Страница 400: ...LS 3408 Product Reference Guide C 6 Codabar MSI Interleaved 2 of 5 A1234567890A 123456789 12345678912345...

Страница 401: ...D Numeric Bar Codes 0 1 D 3 2 3 4 D 4 5 6 7 D 5 8 9 D 6 Cancel D 7...

Страница 402: ...LS 3408 Product Reference Guide D 2...

Страница 403: ...Numeric Bar Codes D 3 0 1 For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1...

Страница 404: ...LS 3408 Product Reference Guide D 4 2 3 4 For parameters requiring specific numeric values scan the appropriately numbered bar code s 2 3 4...

Страница 405: ...Numeric Bar Codes D 5 5 6 7 For parameters requiring specific numeric values scan the appropriately numbered bar code s 5 6 7...

Страница 406: ...LS 3408 Product Reference Guide D 6 8 9 For parameters requiring specific numeric values scan the appropriately numbered bar code s 8 9...

Страница 407: ...Numeric Bar Codes D 7 Cancel In case of an error or to change the selection scan the bar code below Cancel...

Страница 408: ...LS 3408 Product Reference Guide D 8...

Страница 409: ...ociation for manufacturers of automatic identification systems Alphanumeric A character set that contains letters numbers and other characters such as special symbols Aperture The opening in an optica...

Страница 410: ...quiet zones Bar The dark element in a printed bar code symbol Bar Code An array of parallel rectangular bars and spaces arranged according to the encodation rules of a particular symbol specification...

Страница 411: ...t Binary digit One bit is the basic unit of binary information Generally eight consecutive bits compose one byte of data The pattern of 0 and 1 values within the byte determines its meaning Byte A seq...

Страница 412: ...specifying the way in which data may be represented as numbers and letters used to represent information Code 128 A high density symbology which allows the controller to encode all 128 ASCII characte...

Страница 413: ...nd and structured append Continuous Code A bar code or symbol in which all spaces within the symbol are parts of characters There are no intercharacter gaps in a continuous code The absence of gaps al...

Страница 414: ...ist in determining physical size and distortion There are 2 types of Data Matrix symbologies ECC 000 140 with several available levels of convolutional error correction and ECC 200 which uses Reed Sol...

Страница 415: ...e symbol consisting of30 dark elements and 29 intervening light elements Each character is represented by 2 bars and 2 spaces over 7 modules A bar may be comprised of 1 2 3 or 4 modules Each EAN U P C...

Страница 416: ...embles a picket fence Host Computer A computer that serves other terminals in a network providing such services as computation database access supervisory programs and network control IEC Internationa...

Страница 417: ...r s particular chemical composition Matrix Symbols A 2 dimensional array of regular polygon shaped cells where the center to center distance of adjacent elements is uniform The arrangement of the cell...

Страница 418: ...ol Most UPC EAN codes are used over a range of magnifications e g from 0 80 to 2 00 of nominal Non Contact Reader Scanner Bar code readers requiring no physical contact with the printed symbol Non rea...

Страница 419: ...would result in a successful decode In a well designed bar code scanning system that probability should approach near 100 Pitch Rotation of a bar code symbol in an axis parallel to the direction of th...

Страница 420: ...d by a particular reading device or printed with a particular device or method RSS Reduced Space Symbology A family of space efficient symbologies developed by UCC EAN Scan Area Area intended to conta...

Страница 421: ...n material on which a substance or image is placed Symbol A scannable unit that encodes data within the conventions of a certain symbology usually including start stop characters quiet zones data char...

Страница 422: ...ter consists of two bars and two spaces each of which is any of four widths The standard symbology for retail food packages in the United States Variable Length Code A code with a number of encoded ch...

Страница 423: ...s 14 8 move cursor past a character 14 31 move cursor to a character 14 31 move cursor to start of data 14 31 numeric keypad 14 24 pad spaces 14 40 pad zeros 14 46 rules 14 3 rules hierarchy 14 7 send...

Страница 424: ...s 14 9 specific data string 14 22 turn off rule sets 14 103 zero removal 14 38 aiming 2 7 ASCII Values 6 25 B bar codes 123Scan 11 4 beep after good decode 4 8 beeper tone 4 5 beeper volume 4 6 data o...

Страница 425: ...12 42 I 2 of 5 transmit check digit 12 42 ISBT 128 12 23 MSI 12 49 MSI check digit algorithm 12 52 MSI check digits 12 51 MSI lengths 12 49 MSI transmit check digit 12 52 supplementals 12 13 UCC EAN...

Страница 426: ...crete 2 of 5 12 43 lengths 12 43 H host types keyboard wedge 5 6 RS 232 6 8 wand emulation 9 6 I IBM 468X 469X connection 8 4 IBM 468X 469X default parameters 8 5 IBM 468X 469X parameters 8 6 informat...

Страница 427: ...ecting to an IBM 468X 469X host 8 4 connecting using scanner emulation 10 4 connecting using wand emulation 9 4 installing the cable 1 5 unpacking 1 4 signal descriptions 3 9 specifications 3 7 standa...

Страница 428: ...LS 3408 Product Reference Guide IN 6...

Страница 429: ...re you with this product before using this manual Did this manual meet your needs If not please explain ___________________________________________________________ ____________________________________...

Страница 430: ......

Страница 431: ......

Страница 432: ...Symbol Technologies Inc One Symbol Plaza Holtsville New York 11742 1300 http www symbol com 72 67133 01 Revision A February 2004...