background image

CRD 1500

Modem/Charging Cradle

Programmer’s Guide

Содержание CRD 1500

Страница 1: ...CRD 1500 Modem Charging Cradle Programmer s Guide...

Страница 2: ...2 72E 52775 01 Revision A May 2001 Symbol Technologies Inc One Symbol Plaza Holtsville N Y 11742 CRD 1500 Modem Charging Cradle Programmer s Guide...

Страница 3: ...CRD 1500 Modem Charging Cradle Programmer s Guide 72E 52775 01 Revision A May 2001...

Страница 4: ...from a licensed program or use a licensed program in a network without written permission from Symbol The user agrees to maintain Symbol s copyright notice on the licensed programs delivered hereunder...

Страница 5: ...AT x Write to Selected S Register 1 2 AT Read Selected S Register 1 2 A Answer 1 2 Bn CCITT or Bell 1 3 Cn Carrier Control 1 3 En Command Echo 1 5 Fn Select Line Modulation 1 6 Hn Disconnect Hang Up...

Страница 6: ...33 MS Select Modulation 1 34 Chapter 2 S Registers Factory Defaults 2 1 S Register Definitions 2 4 S0 Number of Rings to Auto Answer 2 4 S1 Ring Counter 2 4 S3 Carriage Return Character 2 5 S4 Line F...

Страница 7: ...Character 2 18 S34 S35 Reserved 2 18 S36 LAPM Failure Control 2 18 S37 Desired Line Connection Speed 2 19 S38 Delay Before Forced Hang Up 2 20 S40 General Bit Mapped Options Status 2 21 S41 General B...

Страница 8: ...vi CRD 1500 Modem Charging Cradle Programmer s Guide...

Страница 9: ...e SPT 1500 or SPT 1550 You refers to the developer or other person using this manual as a reference to develop applications for the SPT 1500 or SPT 1550 Italics are used to highlight specific items in...

Страница 10: ...er has not been kept contact Symbol to have another sent to you Symbol Support Centers For service information warranty information or technical assistance contact or call the Symbol Support Center in...

Страница 11: ...stributor Operations Contact your local distributor or call 44 118 945 7360 Finland Oy Symbol Technologies Kaupintie 8 A 6 FIN 00440 Helsinki Finland 9 5407 580 Inside Finland 358 9 5407 580 Outside F...

Страница 12: ...chnologies Kerkplein 2 7051 CX Postbus 24 7050 AA Varsseveld Netherlands 315 271700 Inside Netherlands 31 315 271700 Outside Netherlands Norway Symbol Technologies Trollasveien 36 Postboks 72 1414 Tro...

Страница 13: ...l Authorization Number Products must be shipped in the original or comparable packaging shipping and insurance charges prepaid Symbol will ship the repaired or replacement product freight and insuranc...

Страница 14: ...g from the use of any product shall in no way exceed the purchase price of said product except in instances of injury to persons or property Some states or jurisdictions do not allow the exclusion or...

Страница 15: ...m has additional Data Compression MNP5 V42bis for faster throughput to take advantage of the higher serial port speeds to the SPT1500 Error Correction MNP4 V42 is also included This chapter describes...

Страница 16: ...elected S Register Description Writes the value x to the currently selected S Register Use the ATSn command to select an S Register All S Registers return OK if x is a number Some registers may not be...

Страница 17: ...lid is written to S27 bit 6 See Fn Select Line Modulation on page 1 6 B0 Selects CCITT operation at 300 or 1200 bps during Call Establishment and a subsequent connection B1 Selects BELL operation at 3...

Страница 18: ...A B C and D L Re dial last number the modem re dials the last valid telephone number The L appears immediately after the D characters that follow are ignored P Select pulse dialing pulse dial the numb...

Страница 19: ...modem to the command state after processing the portion of the dial string preceding the This allows you to issue additional AT commands while remaining off hook Place these commands in the original c...

Страница 20: ...valent to command string ATN0S37 1 F2 Not supported F3 Selects V 23 as the only acceptable line modulation for a subsequent connection Originator is at 75 bps and answerer is at 1200 bps Sets N0 sets...

Страница 21: ...s connection at the Rockwell proprietary 12000 V 32 speed e g with a RC9696 12 based modem F10 Selects V 32 bis 14400 as the only acceptable line modulation for a subsequent connection Sets N0 sets S3...

Страница 22: ...quivalent to setting the MS automode subparameter to 1 This command is also equivalent to Default Result Codes OK n 0 or 1 ERROR Otherwise Notes 1 The Nn and S37 x commands override the MS command set...

Страница 23: ...the DTE back to the remote modem after an escape O1 Enters on line data mode with a retrain before returning to on line data mode Result Codes OK n 0 or 1 and a connection exists ERROR Otherwise or if...

Страница 24: ...ister accessed n v Sets S Register n to the value v n Reports the value of S Register n Omit the parameter n to assume the last S Register accessed Omit the S for AT and AT to assume the last S Regist...

Страница 25: ...mand is received The modem sets an S Register bit to conduct all subsequent dialing in tone mode The DP command overrides this command Clears S14 bit 5 Result Code OK Vn Result Code Form Description S...

Страница 26: ...s are disabled Result Codes OK n 0 1 or 2 ERROR Otherwise Xn Extended Result Codes Description Selects which subset of the result messages are used by the modem to inform the DTE of the results of com...

Страница 27: ...d 4 respectively X3 Enables monitoring of busy tones send only OK CONNECT RING NO CARRIER ERROR NO ANSWER and CONNECT XXXX If dial tone detection is enforced and dial tone is not detected NO CARRIER i...

Страница 28: ...x x x 18 CONNECT 57600 1 x x x x 19 CONNECT 115200 1 x x x x 22 CONNECT 75TX 1200RX 1 x x x x 23 CONNECT 1200TX 75RX 1 x x x x 24 DELAYED 4 4 4 4 x 32 BLACKLISTED 4 4 4 4 x Table 1 1 Result Codes con...

Страница 29: ...NE x x x x x 70 PROTOCOL NONE x x x x x 77 PROTOCOL LAPM x x x x x 80 PROTOCOL ALT x x x x x 81 PROTOCOL ALT CELLULAR x x x x x F4 FCERROR x x x x x Table 1 1 Result Codes continued Short Form Long Fo...

Страница 30: ...m sends a long space of four seconds before going on hook and responds to the receipt of a long space i e a break signal greater than 1 6 seconds by going on hook Result Codes OK n 0 or 1 ERROR Otherw...

Страница 31: ...erpreted according to the current Qn setting as follows Q0 Q1 Q4 The modem as if the asynchronous escape sequence Q5 Q6 was entered and returns to asynchronous command state without disconnecting Q2 Q...

Страница 32: ...of a subset of S Registers F0 Restore factory configuration 0 F1 Restore factory configuration 1 Result Codes OK ERROR If the modem is connected Gn Select Guard Tone Description Generates the guard t...

Страница 33: ...l Result Codes OK n 0 3 4 5 or 6 ERROR Otherwise Mn Asynchronous Synchronous Mode Selection Description Determines the DTR operating mode The modem treats the M command as a subset of the Q command M0...

Страница 34: ...values before selecting AutoSync operation with Q4 After the CONNECT message is issued the modem waits the period of time specified by S25 before examining DTR If DTR is on the modem enters the synchr...

Страница 35: ...s Description Performs selected test and diagnostic functions according to the parameter supplied A test can be run only when in an asynchronous operation in non error correction mode normal or direct...

Страница 36: ...ppears upon the start of the test T7 Requests a remote digital loopback RDL V 54 Loop 2 with self test In self test a test pattern is looped back and checked by the modem If no connection exists ERROR...

Страница 37: ...7 030 S08 002 S09 006 S10 014 S11 255 S12 050 S18 000 S25 005 S26 001 S36 007 S37 000 S38 020 S46 138 S48 007 S95 000 STORED PROFILE 0 B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 C0 D0 G2 J0 K3 Q5 R1 S0 T4 X0 S00...

Страница 38: ...UALITY 030 Highest SPX RX state 068 Highest SPX TX state 067 Wn Store Current Configuration Description Saves the current active configuration profile including S Registers in one of the two user prof...

Страница 39: ...Y1 The modem uses profile 1 Result Codes OK n 0 to 1 ERROR If n 1 or if NVRAM is not installed or is not operational Zn x Store Telephone Number Description The modem can store up to four telephone n...

Страница 40: ...data compression Sets S46 bit 1 default Result Codes OK n 0 1 2 or 3 ERROR Otherwise En Enable Disable Line Quality Monitor and Auto Retrain or Fallback Fall Forward Description Controls whether the...

Страница 41: ...done without a retrain if a V 32 bis connection is established Speeds attempted during fallback fall forward are those available in the rate sequences exchanged during the initial connection Fallback...

Страница 42: ...Transmit Break to Remote Description In non error correction mode the modem transmits a break signal to the remote modem with a length in multiples of 100 ms according to parameter specified If a num...

Страница 43: ...reak from the DTE when the modem is operating in data transfer mode K0 Enter on line command mode no break sent to the remote modem K1 Clear data buffers and send break to remote modem K2 Enter on lin...

Страница 44: ...1 30 CRD 1500 Modem Charging Cradle Programmer s Guide K4 Send break to remote modem in sequence with data K5 Send break to remote modem in sequence with data default...

Страница 45: ...ear data buffers and send break to the DTE K1 Clear data buffers and send break to the DTE K2 Send a break immediately to DTE K3 Send a break immediately to DTE K4 Send a break in sequence with receiv...

Страница 46: ...re to make a reliable connection causes the modem to hang up Forces Q5 S36 4 and S48 7 N3 Selects auto reliable mode This is similar to N2 except failure to make a reliable connection results in the m...

Страница 47: ...pported The modem responds to either command format but the ITU V 250 GCI format is recommended for new code NCyy Changes country code where yy is the code defined in the following table The new count...

Страница 48: ...optionally enables or disables automode specifies the lowest and highest connection rates selects Law or A Law codec type and enables or disables robbed bit signaling generation server modem or detec...

Страница 49: ...x_law rb_signaling For example MS 56 1 300 56000 0 0 MS 11 1 300 33600 0 0 MS 10 1 300 14400 0 0 Reporting Supported Options The modem can send a string of information to the DTE consisting of support...

Страница 50: ...ch from certain modulations specified by mod For example there is no standard way to automode from Bell 103 to V 23 The DTE may disable automode operation see automode below The DTE may constrain the...

Страница 51: ...00 9600 7200 or 4800 bps To emulate the N0S37 x command sequence to select fixed mode operation set the max_rate and min_rate to the same requested speed and mod to be the modulation for that speed Fo...

Страница 52: ...default is 28800 for 28800 bps x_law an optional number which specifies the codec type The options are 0 Law 1 A Law Note that ATZ resets the x_law selection to 0 Law rb_signalling an optional number...

Страница 53: ...e the appropriate AT command that controls the relevant bits in the S Register to change the value Factory Defaults The factory default values are stored in ROM and are loaded into the active configur...

Страница 54: ...255 s 50 S8 Pause Time for Dial Delay Modifier 0 255 s 2 S9 Carrier Detect Response Time 1 255 0 1 s 6 S10 Carrier Loss Disconnect Time 1 255 0 1 s 14 S11 DTMF Tone Duration 0 001 s 95 S12 Escape Pro...

Страница 55: ...S32 XON Character 0 255 ASCII 17 11h S33 XOFF Character 0 255 ASCII 19 13h S34 S35 Reserved S36 LAPM Failure Control 7 S37 Line Connection Speed 0 S38 Delay Before Forced Hangup 0 255 s 20 S39 Flow Co...

Страница 56: ...255 rings Default 1 S1 Ring Counter Description S1 is incremented each time the modem detects a ring signal on the telephone line S1 is cleared if no rings occur over an eight second interval Range 0...

Страница 57: ...43 S3 Carriage Return Character Description Sets the command line and result code terminator character Pertains to asynchronous operation only Range 0 127 ASCII decimal Default 13 Carriage Return S4...

Страница 58: ...the Backspace character Range 0 32 ASCII decimal Default 8 Backspace S6 Wait Time for Dial Tone Before Blind Dialing or After W Dial Modifier Description Sets the length of time in seconds the modem...

Страница 59: ...r silence when encountering the dial modifier before continuing with the next dial string parameter Range 1 255 seconds Default 50 S8 Pause Time For Dial Delay Description Sets the time in seconds the...

Страница 60: ...ption Defines the maximum time in fiftieths of a second allowed between receipt of the last character of the three escape character sequence from the DTE and sending of the OK result code to the DTE I...

Страница 61: ...is ignored Bit 1 Command echo En 0 Disabled E0 1 Enabled E1 default Bit 2 Quiet mode Qn 0 Send result codes Q0 default 1 Do not send result codes Q1 Bit 3 Result codes Vn 0 Numeric V0 1 Verbose V1 def...

Страница 62: ...nabled T1 Bit 1 Not used Bit 2 Local digital loopback 0 Disabled default 1 Enabled T3 Bit 3 Remote digital loopback RDL status 0 Modem not in RDL default 1 RDL in progress Bit 4 RDL requested AT T6 0...

Страница 63: ...ssage upon test termination Range 0 255 seconds Default 0 S19 AutoSync Bit Mapped Options Description Defines the options for AutoSync operation see Qn Sync Async Mode on page 1 20 S19 must be set to...

Страница 64: ...re issuing Q4 Range 0 255 Default 0 S21 V 24 General Bit Mapped Options Status Description Indicates the status of command options Default 52 34h 00110100b Bit 0 Set by Jn command but ignored otherwis...

Страница 65: ...ng space disconnect Yn 0 Y0 default 1 Y1 S22 Speaker Results Bit Mapped Options Status Description Indicates the status of command options Default 117 75h 01110101b Bits 0 3 Reserved Bits 4 6 Limit re...

Страница 66: ...Default 62 3Dh 00111110b Bit 0 Grant RDL 0 RDL not allowed T5 default 1 RDL allowed T4 Bits 1 3 DTE Rate 0 0 300 bps 1 600 bps 2 1200 bps 3 2400 bps 4 4800 bps 5 9600 bps 6 19200 bps 7 38400 bps or h...

Страница 67: ...ty will cause the modem to enter the sleep mode Range 0 255 seconds Default 0 S25 Delay To DTR Description Sets the length of time the modem ignores DTR for taking the action specified by Dn Its units...

Страница 68: ...Q0 0 0 1 M1 or Q1 0 1 0 M2 or Q2 0 1 1 M3 or Q3 1 0 0 Q4 1 0 1 Q5 default 1 1 0 Q6 Bit 2 Leased line control Ln 0 Dial up line L0 default Bits 4 5 Internal clock select Xn 0 Internal clock X0 default...

Страница 69: ...timer In other modes any data transmitted resets the timer The timer is inoperative in synchronous mode Range 0 255 tens of seconds 0 2550 seconds Default 0 disabled S31 Bit Mapped Options Status Defa...

Страница 70: ...options are initiated immediately upon connection if S48 128 If an invalid number is entered the number is accepted into the register but S36 behaves as if the default value was entered 0 Modem discon...

Страница 71: ...x commands Nn and S37 x commands are supported for compatibility with existing communication software Default 0 Bits 0 4 Desired line connection speed This is interlinked with the Fn command If an inv...

Страница 72: ...programmed to follow the signal and the disconnect operation Applicable to error correction connection only Use this register to ensure that data in the modem buffer is sent before the modem disconnec...

Страница 73: ...K6 Bits 3 7 Reserved S40 General Bit Mapped Options Status Description Indicates the status of command options Default 104 68h 01101000b Bits 0 1 MNP Extended Services Kn 0 Disable extended services...

Страница 74: ...options Default 195 C3h 11000011b Bits 0 1 Compression selection Cn 0 Disabled C0 1 MNP 5 C1 2 V 42 bis C2 3 MNP 5 and V 42 bis C3 default Bits 2 6 Auto retrain and fallback fall forward En Bit 6 Bit...

Страница 75: ...dem However when these capabilities are known and negotiation is unnecessary this process can be bypassed Range 0 7 or 128 If an invalid number is entered it is accepted into the S Register but S48 be...

Страница 76: ...nd S86 9 The modems could not find a common protocol S86 12 Normal disconnect initiated by the remote modem S86 13 Remote modem does not respond after 10 re transmissions of the same message S86 14 Pr...

Страница 77: ...2 25 S Registers Bit 4 Reserved Bit 5 Enable COMPRESSION result code XXXX compression type Bit 6 Reserved Bit 7 Reserved...

Страница 78: ...2 26 CRD 1500 Modem Charging Cradle Programmer s Guide...

Страница 79: ...n 1 10 quiet results code 1 10 read s register 1 2 read write s register 1 10 reexecute 1 2 result code form 1 11 select line modulation 1 6 select maximum MNP block size 1 28 set tone dial default 1...

Страница 80: ...kspace character 2 6 bit mapped options status 2 9 2 14 2 16 2 17 2 21 2 22 bit mapped test options status 2 10 blind dial wait time 2 6 break handling options 2 23 BSC sync character 2 12 call failur...

Страница 81: ...8 S35 2 18 S36 2 18 S37 2 19 S38 2 20 S39 2 21 S4 2 5 S40 2 21 S41 2 22 S46 2 23 S48 2 23 S5 2 6 S6 2 6 S7 2 7 S8 2 7 S82 2 23 S86 2 24 S9 2 7 S95 2 24 sleep inactivity timer 2 15 speaker bit mapped o...

Страница 82: ...Index 4 SPT 1500 1550 Programmer s Reference Guide...

Страница 83: ...uct before using this manual Did this manual meet your needs If not please explain ___________________________________________________________ _________________________________________________________...