Symbiote SWEG28J Скачать руководство пользователя страница 1

Symple Height Adjustable Base

1.  Turn tabletop upside down. Extend stretcher to desired length, 45" to 68", adjustable in 2" steps. The  

 

stretcher must not be pulled completely apart in order not to pull the drive shaft apart. Minimum 

 

 

adjustment in the connection end is 4" (to keep power and RJ45 connector ports accessible); otherwise 

 

adjustable in 2" steps.

Notes

:

•  This product is shipped in separate boxes. Check packaging and items for visible damage and ensure the 

drive shaft is mounted correctly and not pulled apart.

•  Read this manual, completely, before using this product.  Failure to follow instructions and safety precau-

tions in this manual can result in property damage, serious injury, or death.

•  Use with 24", 30" and 36" D surfaces to construct a height adjustable table.
• 

Telescoping expandable base fits surface widths from 48" to 96".

•  This product contains an automatically-reset thermal limiter which protects the unit from damage due to 

heat generation. Continuous use may result in a temporary shutdown of the electric height adjustment 

feature of the table base. If this occurs, please allow a cooling period of two hours before resuming normal 

use.  The electric height adjustment feature of this product is not intended for continuous operation. The 

duty cycle is 5 % ≈ 1-minute continuous use at full load, followed by a 19-minute pause. 

•  Electrical rating: 120V, 60 Hz, 3 Amps

WARNING

:  Do not tighten the #10-12 surface screws more than 25 in-lbs. in laminated surfaces or 40 in-lbs. 

in phenolic surfaces. Silicone adhesive recommended to attach epoxy surfaces. 

Product Numbers

•  SWEG28J

Hardware Pack:  

SWEHP (p/n 20103111-01)

Required Tools

•  ³/

16

" Allen Wrench

•  #2 Phillips Bit

•  Cordless Drill/Driver

• 

Tape Measure

 

Stretcher

    Cantilever (x2)

Feet (x2)

Leg (x2)

INSTALLATION INSTRUCTIONS

p/n 20102501-01 rev A

SYMBIOTE.COM

sheet 1 of 8

Содержание SWEG28J

Страница 1: ...rface widths from 48 to 96 This product contains an automatically reset thermal limiter which protects the unit from damage due to heat generation Continuous use may result in a temporary shutdown of the electric height adjustment feature of the table base If this occurs please allow a cooling period of two hours before resuming normal use The electric height adjustment feature of this product is ...

Страница 2: ...er using the cantilevers as handles 4 Place assembled table base in correct position on the underside of surface Use tape measure to ensure correct placement 5 Fasten table base to surface using 20 mounting screws according to the diagram s reference letters a c c c c b a a 8 screws at ends of stretcher Secure power supply cord to stretcher with cord creating a strain relief Connect main power cor...

Страница 3: ...on Check both pawls are visible after mounting of legs Otherwise remove leg and repeat procedure see disassembly steps 7 Tilt legs and place correctly on stretcher using guiding notches 6 Mount legs Ensure legs are completely retracted INSTALLATION INSTRUCTIONS p n 20102501 01 rev A SYMBIOTE COM sheet 3 of 8 ...

Страница 4: ...o adjacent RJ45 connector port 11 Mount feet on legs using four M6 x 16mm mounting screws per leg into the threaded holes Tighten screws thoroughly torque max 90 in lbs 9a Mount hand control switch Connect hand control switch in RJ45 connector port Fasten hand control switch to surface using mounting screws Fasten cord to surface using two screws and cord clamps INSTALLATION INSTRUCTIONS p n 20102...

Страница 5: ...bly tool has ridges on one side 1 Lower desk to its minimum height so legs are completely retracted 2 Disconnect from power supply 3 Turn table upside down 4 Disconnect unscrew and remove hand control switch 5 Unscrew and remove feet 6 Place disassembly tool on stretcher with ridges facing toward the cantilever 7A Press straight down to loosen cantilever and make pawl release leg 7B At the same ti...

Страница 6: ... system has been assembled per these instructions Ensure main power supply voltage is correct before connecting to power Use only the supplied power cord All components must be properly assembled before connecting table to main power supply During operation If the control box makes unusual noise or smells immediately discontinue use and consult factory The maximum total load on the frame is 350 po...

Страница 7: ... near children invalids or disabled persons 3 Use this furnishing only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer 4 Never operate this furnishing if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Return the furnishing to a service center for examination and r...

Страница 8: ...ated product must be identical to the parts they replace A double insulated product is marked with the words DOUBLE INSULATION or DOUBLE INSULATED The symbol square within a square is also able to be marked on the product To reduce the risk of electric shock this furnishing has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does...