122 Chapter 6
NetBackup 5220 hardware removal and replacement
Installing and removing the I/O expansion module
2.
Disconnect the main AC power cord and peripheral cables/cords
from the rear of the NetBackup 5220
3.
Wear ESD preventive wrist straps.
4.
Carefully remove the NetBackup 5220 from the rack cabinet.
5.
Place it on a grounded, ESD protective surface.
6.
Remove the screw on the top, right-hand side of the chassis
7.
Use the thumb grip on the top, left-hand side of the chassis to slide
the cover towards the rear of the device.
Removing the NetBackup 5220 chassis cover
8.
Remove the chassis cover completely.