106 Chapter 6
NetBackup 5220 hardware removal and replacement
Installing or replacing the RAID card and accessories
Rear of riser card assembly with slots 1-5
4.
Replace the internal air duct into the chassis. Be sure it aligns
correctly with the fan module, DIMM slots, CPUs, and side of
the chassis.
Do not move or damage any cables or other connectors located near the air
duct.
5.
Replace the riser card assembly into the chassis.
6.
Align the three hooks in the PCI riser assembly with the
matching slots at the back of the chassis.
7.
Press down evenly until the three hooks on the rear of the PCI
riser assembly engage the chassis rear panel slots.
8.
Be sure that riser assembly fits securely into the equivalent
sockets on the mainboard.
9.
Connect any cables to the RAID card as needed.
10.
Replace the chassis cover from the top rear of the NetBackup
5220 enclosure.
11.
Slide the cover from the rear of the device towards the front.