background image

CF045R1   3/08

Product Information Bulletin

DULUX

®

DT/E/C

4-Pin Amalgam Compact Fluorescent Lamps 

•  Improved high temperature performance

– Maintains 90% lumens from 60°F to 175°F

ambient

•  Latest generation higher temperature rated

composite (metal/plastic) base cap

•  Designed to exceed IEC safety requirements*

•  Extended range of color temperatures: 

3500K, 4100K and 5000K with improved 
color consistency

•  Operates on various ballast systems

– Flicker free start on electronic ballasts
– Compatible with QUICKTRONIC

®

System CF

•  Less power consumption than incandescent of 

comparable light output

•  High luminous efficacy 

•  Long 12,000 hour average rated life

– Reduces relamping requirement and 

related cost

•  Rare earth tri-phosphor with 82 CRI

* Regulations may vary. Check your local and state regulations.

SYLVANIA DULUX DT/E/C industry exclusive amalgam compact
fluorescent lamp is ideal for use in a wide range of high
temperature applications.

DULUX DT/E/C amalgam lamps are ideal for enclosed, exterior
and small fixtures. The lamps have improved amalgam
technology and higher temperature rated components. This 
lamp has the next generation composite (metal/plastic) base cap
which has been designed to exceed IEC safety requirements.

Application Information

Applications

Recessed ceiling fixtures, enclosed exterior fixtures
Industrial lighting
Showcase lighting
Wall sconces
Task lighting
Exit signs
Garden and walkway lighting

Fixtures

Contact your local fixture agent for available fixtures.

Ballast Information

Contact your OSRAM SYLVANIA representative for a list
of compatible operating systems.

Product Availability

Lamp

Wattage Rated 

Lumens

CF42 DT/E/C

42

3200

Application Notes

1. 4-Pin lamps designed for electronic ballast operation. 

Not recommended for dimming.

2. Recommended for use with ballasts that operate the lamp 

in compliance with ANSI/IEC specifications.

3. Minimum starting temperature depends on ballast.
4. Rule of thumb: to estimate the appropriate compact fluorescent

lamp wattage, divide the incandescent wattage by 4.

5. Equipment manufacturers are advised to consult ANSI and 

IEC standards for the maximum allowable dimensions and 
temperature to ensure compatibility with similar products.

System Comparison

Compact Fluorescent vs Incandescent

Rated

System

System

System

Energy

1

Lamp Type

Lamp Life

Lumens

Wattage

LPW

Savings

150W Incandescent

750 hrs.

2740

150W

18.5

DULUX DT/E/C

12,000 hrs.

3200

46W

70

$124.00

1. Based on $.10/kWh over 12,000 hours.