9
CALIBRATION
We suggest the unit is periodically checked for calibration in situ. If the unit is covered by a
service agreement with the MOT package installer, they will carry this out on your behalf.
Should you wish to regularly check the calibration yourself, we recommend you purchase an
Alignment Device from your local dealer. Full instructions are provided with the re-calibration
tool.
OTHER REGULATIONS AND CALIBRATIONS
The machine is equipped with a spirit level located on the base of the optical box and visible
through the transparent panel, with headlights on. If necessary, to level the box open the
clutch lever located on the side of the box itself and move the box until perfectly level, then
re-close the clutch lever. This operation may prove necessary whenever the equipment is
mounted on a different work surface.
Correct use of the machine permits long periods of use without significant maintenance.
Eventual calibration of the panel and luxmeter must be carried out on our premises, sending
just the optical box that can be easily dismounted by removing the screws.
CLEANING
It is good practice to protect the instrument from dust when not in use. A plastic cover for
the optical box is available on request.
Occasionally clean with a damp cloth and remove any stains. Paintwork is detergent
resistant. Do not oil the column, or use alcohol for stain removal.
Do not leave the machine in areas where corrosive vapor is present, for example in battery
charging or painting areas.
DEMOLITION AND DISPOSAL
The machine is composed of:
Glass (lens)
Plastic (wheels, Plexiglas cover, handles and other small details)
Copper (wiring and luxmeter coils)
Steel (structure and mechanics) up to 80%
Paper and cardboard (instruction manual, packaging)
The machine is constructed principally of steel. For disposal of this material, local authority
regulations must be observed.