HYDRO’pH
®
,
HYDR’ORP
®
,
HYDRO’pH Duo
®
and
HYDRO’pH/ORP
®
instructions
8
Wintering
CAUTION:
The sensors should never stay dried during the winter in the pool
hose.
Sensors should be kept in a dry place, away from moisture in their
original packing.
A conservation agent is available from your installer. If you forget,
put tap water in the sensor cover, and store it in its original packing.
The lifetime of the sensors depends on the use and conservation.
In normal use, the duration exceeds three years. In case of poor
preservation or abnormal use, it can be reduced to a few months!
If these precautions are not taken, the sensors will not
operate next season.
CAUTION:
The metering pumps should also be wintered.
Run clean water into the pumps tubing.
Disconnect the tubes in case of frost.
Set the pressure rollers of metering pumps according to the position
« 7:05 » by turning the roller holder in the direction of clockwise.
If these precautions are not observed, the pumps will not
operate next season. “Tygon” tube will then be marked
and destroyed.
CAUTION:
Stop pH control by cutting power.
No special precaution has to be performed.
CAUTION:
Empty cans of chemicals.
NOTE:
The chemicals used in pools can be dangerous and corrosive! They
can damage your health and cause environmental damage.
Any mixture of chemicals can be hazardous to health and should
never be done!