background image

Operating instructions

RES.Q DE955
Terminal for receiving
alarm messages
with a feedback function
and position finding

090227_e-RES-Q-DE955.qxd:45331_d-Bedanl.qxd

2.2.2009

9:01 Uhr

Содержание RES.Q DE955

Страница 1: ...Operating instructions RES Q DE955 Terminal for receiving alarm messages with a feedback function and position finding 090227_e RES Q DE955 qxd 45331_d Bedanl qxd 2 2 2009 9 01 Uhr...

Страница 2: ...nu structure 10 Menu 12 Messages 13 Conforming messages 16 Location only for RES Q DE955 GP 17 Zonal alarms Geo alarm only for RES Q DE955 GP 17 Profile 18 Alarms 19 Alarm clock 21 Settings 23 Battery...

Страница 3: ...you with important information about how to get the best from your device Please keep these instructions handy in order to consult them if need be The RES Q DE955 can be configured to meet the custome...

Страница 4: ...ent where there is the risk of explosions This device should not be opened and the labelling should not be removed 4 The device complies with the regulations of the R TTE European Directive 99 05 EU Y...

Страница 5: ...only use genuine charging devices from the Swissphone range of accessories Important information Do not expose lithium polymer rechargeable batteries to high temperatures Do not destroy lithium polyme...

Страница 6: ...becomes visible on the display This function requires that messages are sent at regular intervals Type of alarm Stand by profile with extension profile Charging device display Date and time Key lock...

Страница 7: ...Alarms No audible alarm see section on Alarms The alarm clock function is switched on or delayed see Alarm clock Key lock is activated see section on Key lock Feedback channel switched off see sectio...

Страница 8: ...ower scroll key bottom Scroll down through the menu Change settings Display of status information in stand by mode Top scroll key top Scroll upwards through the menu Change settings Return to stand by...

Страница 9: ...deactivate the key lock function The key lock function can be deactivated by pressing the top scroll key top and the lower scroll key bottom at the same time and then letting go of the keys To read th...

Страница 10: ...latest message Messages Profile Alarms Alarm clock Settings Switch off Back Read Messages Saved Messages Folder A Folder B Back Back Save message Delete message Delete message list Back Unsave messag...

Страница 11: ...ontrast Backlight Message font Language Melodies Call reminder Out of range alarm Key click Confirmation tone Key vibration Key lock GPS GSM EA monitor Back 090227_e RES Q DE955 qxd 45331_d Bedanl qxd...

Страница 12: ...u is obtained or else there is a change to the submenu that has been selected The current menu can be exited in each case by means of the menu item Back Directly switching back to the stand by mode To...

Страница 13: ...alarm setting that is in use at the time To stop the audible alarm press any key With the acknowledgement key OK or the lower scroll key bottom scroll through the various items and the message will b...

Страница 14: ...Read Messages At the end of the message by pressing the confirmation key OK the menu to save or delete this message will be shown Additionally the complete message list can be deleted Using Save messa...

Страница 15: ...h up to two message files depending on how it has been programmed Although messages which are filed in the message files will be displayed you will not receive an alarm They can not or must not be des...

Страница 16: ...to the alarm setting that is in use at the time To stop the audible alarm press any key With the confirmation key OK or the lower scroll key bottom then you will scroll through the items and the messa...

Страница 17: ...iver module which is integrated into the RES Q DE955 GP it is possible at the same time the response is given to an alarm to provide information to the con trol centre about the location of your devic...

Страница 18: ...u item Profile using the bottom key Press OK again Select the desired profile using bottom and top Activate and save the profile that has been selected using OK The profile extension can then be activ...

Страница 19: ...te vibration only and Off visual display only Initial position stand by mode Press OK and the menu item Read latest message will be displayed Choose the menu item Alarms using the bottom key Press OK...

Страница 20: ...ur of the alarm corresponding to the following configurations 20 Audible alarm Vibration Symbol Alarm Alarm for a priority message Loud Standard signal Double length standard signal Discrete 10 second...

Страница 21: ...ing the alarm on and off and setting the time the alarm will go off Initial position menu item Alarm clock Press the bottom key in order to select the menu On Off Switch to setting the time using the...

Страница 22: ...t alarm function is active the alarm clock symbol flashes in the stand by display Using Stop the alarm clock is switched off for the whole day The alarm clock does however remain active and will wake...

Страница 23: ...ou will always be alerted of new messages with the display backlight switched on Message font Choose between standard 4 lines small 5 lines or large 3 lines For each font size there is a choice betwee...

Страница 24: ...of the keys Confirmation tone Activate or deactivate the confirmation sound for inputs Key vibration Activate or deactivate key vibration by scrolling through the menu Key lock Activate or deactivate...

Страница 25: ...te the response to messages EA monitor Activate or deactivate the express alarm monitor This function is only activated if your system supports express alarms 25 090227_e RES Q DE955 qxd 45331_d Bedan...

Страница 26: ...the same time there is a sound produced at regular intervals to remind you about the battery There is still at least 24 hours of operational service available to you By pressing the acknowledgement ke...

Страница 27: ...ch off Switch the terminal off using the OK and bottom keys Switching on Should the RES Q DE955 be found to be switched off it can be switched on by pressing any key for a long time Switching on using...

Страница 28: ...e 21 CH 8833 Samstagern Switzerland Customer Service Swissphone Telecom AG Reserves the right to make technical changes without prior notification CH 02 09 Art Nr 03432XXX 090227_e RES Q DE955 qxd 453...