4 Electrical Interfaces
The following subsections contain information for the electrical interfaces of the Tile.
4.1 User Host Device
The user host device provides the following connections to the Tile:
● DC power supply input: 3.3V, 1000 mA peak
○ The DC power supply is required to be contained within an EMI shielding can
○ Additional filtering of the 3.3V supply is highly recommended
● 3.3 volt serial data interface
● Satellite signal (Use either the provided U.FL connector labeled SAT
or
Pin 18. See
section 5.3 - RF Trace Layout Design for more information)
● GPS signal (Use either the provided U.FL connector labeled GPS
or
Pin 8)
● GPIO_1 (optional)
October 2020
Swarm Tile Manual - Rev 1.10
16/65