1 Introduction 

On the following pages you will learn how to install and 
operate the device in an appropriate way. We attach great 
importance to the safe, appropriate and effective handling 
of this device. It is therefore important to read this manual 
thoroughly before using the device. 
 

 

 

In the manual you will find important instructions helping 
you to avoid danger and to prolong the reliability and du-
rability of the device and the accessories. 

 

For your own safety you should read the safety instruc-
tions. Follow the instructions closely in order to avoid dan-
ger for yourself and others or damage to the device. 

 

If you have any questions about the IG315/2, which are 
not answered in this manual, or if you have problems un-
derstanding the descriptions, please contact: 

 

SWARCO TRAFFIC SYSTEMS GMBH 

Business Unit Detection 

Niederkircher Straße 16 

D-54294 Trier 

[email protected] 

 
 

1.1 Usage according to regulations 

The IG315/2 is solely suited for the detection of vehicles. 
Any further usage is not appropriate. Do not use the 
IG315/2 for any other purpose. 
 

1.2 Label 

The IG315/2 is provided with a quality label / serial num-
ber. You will need these indications when talking with the 
customer service, e.g. ordering accessories or spare 
parts. 

 

 

Note here the serial number and name of the device in or-
der to have them available when needed: 

 

Serial number: 

 

 ________________________________________ 

 

Voltage version: 

 

 ________________________________________ 

 

CE-label:  

 

1.3 Further documentation 

Notes on loop installation 

 

1.4 Symbols 

In several places throughout this manual you will find the 
following symbols stating important safety instructions: 

 

 

 ATTENTION! 

 

This symbol indicates dangers which might cause damage 
to people or property. 
 

Note 

This symbol indicates information for installation and  
function of the device. 

 

1.5 Safety instructions 

Read the following safety instructions thoroughly and ob-
serve them carefully. They are stated to ensure your own 
safety and the safety of others and to avoid damage to the 
device or accessories. 

 

 

 

 

ATTENTION!  

 

Danger of electricity! Make sure that no liquid may get  
inside the device. If this happens, interrupt the power  
supply to the device at once.  

 

If you notice any damage, e.g. broken or crushed cables, 
damaged plugs, enclosures etc., turn off the device at 
once, interrupt the power supply and make sure that the 
device cannot accidentally be turned on again. 

 

The device may only be installed, brought into service and 
repaired by an electro-technical expert. Inappropriate  
operation, improper maintenance or not observing the  
instructions in this manual can lead to danger. 

 

Any malfunction of the device which may limit the safety  
of its users or others must be removed immediately. All 
warning and safety labels on the device must be observed 
and kept complete and legible. 

 

The appropriate usage must be observed by all means. 
For damage resulting from inappropriate usage the manu-
facturer will not undertake any liability. 

 

The device must not be used as a safety component in the 
sense of the European Directive 98/37/EC ("Machinery Di-
rective”). In systems with high risk additional safety meas-
ures are necessary. 

 

 

The operator of the device must ensure that the chosen 
means of operation will not cause damage to material or 
danger to people and that all security and safety installa-
tions are present and functioning. 

 

Before installation and first operation, please observe the 
instructions in the manual. 

 

The manual must be available at the site of usage at any 
time. It must be read thoroughly and applied appropriately 
by the person responsible for the operation, maintenance 
and service of the device.

 

 

Note 

 

Our products are in a constant process of improvement 
and advancement. Because of this, read the current man-
ual thoroughly before installation and first operation. 

 

Without prior consent of the manufacturer, no modifica-
tions, neither mechanical nor electrical, may be done.  
Only parts that have the consent of the manufacturer may 
be used for backfitting or as accessories. Any violations 
will lead to the termination of conformity and the manu-
facturer’s warranty. The user will subsequently bear the 
risk (the Declaration of Conformity is available at 

www.swarco.com/sts

)

 

 

 

2 Product description 

2.1 Features 

The induction impulse transmitters IG315/2 evaluate the 
loops in the ground. Those depict the inductivity of a high-
frequency oscillator circuit. If a vehicle crosses the loop, 
its metal components cause a change of frequency in the 
oscillator circuit. These are analysed by the loop detector, 
transmitted as switching signals via floating relay contacts 
and displayed on the front LEDs. The analysis of the loop 
frequency is done via a micro-processor system which 
aligns automatically to the according loop and compen-
sates changes of the loop inductivity caused by tempera-
ture, humidity or aging of components. The induction im-
pulse transmitter IG315/2 is a 1-channel unit, which 
means that this device can connect to and evaluate one 
induction loop. 

 

2.2 Switching outputs 

The switching output is coupled with the LED display (A) 
on the front panel (see 4). There are two switching outputs 
available. Relay A is switched as static signal or impulse 
for the mode “loop occupied”. Relay B emits an additional 
impulse or can be activated as switching output for the fail-
ure report (ERROR) via the operating units on the front. All 
switching outputs are equipped with electro-mechanical 
relays. 

 

 

2.3 Parameter adjustment 

Via the DIP-switches on the front the following parameters 
can be adjusted: 

 sensitivity  

 hold time  

  frequency of the measuring system 

 switch-off delay 

  B-relay as fault report, (instead impulse relay) 

  impulse when leaving the loop 

 switch-on delay 

 automatic alignment 

  detection by fault 

 

2.4 Technical data 

 Technical data 

 

IG315/2 S.T. / 

IG315/2 W.T. / 

IG315/2 ST.T. 

IG315/2 S.V. / 

IG315/2 W.V. / 

IG315/2 ST.V. 

Power supply 

230 V AC: (-10 - +6) % / 4,5 VA 

(50 Hz: +/-0,5 %) 

resp. 24 V AC/DC: +/-10 % / 3 VA 

Operating temperature 

-25

C to +70

C

 

Storage temperature 

-40

C to +80

Safety 

IP30 

Enclosure (plastic) 

l = 75 mm, w = 37 mm, h = 68 mm 

Connection 

via 11-pin connector (type 78-S 11); 

dimension of socket manufacturer-dependent

 

Weight 

240 g

 

Inductivity range 

15 µH to 2000 µH (see also 6.1), 

recommended range: 

100 µH to 300 µH at max. 30 

 

 

 

 Technical data 

 

IG315/2 S.T. / 

IG315/2 W.T. / 

IG315/2 ST.T. 

IG315/2 S.V. / 

IG315/2 W.V. / 

IG315/2 ST.V. 

Sensitivity 
adjustable  
per channel  

7 levels adjustable 

from High 0.01 to 

Low 0.9  

per channel adjust-

able in 4 levels from 

High 0.01 to Low 0.9 

(adjustment of frequency in %)  

Hold time 

impulse mode 100 

ms (optional 1 s) 

and static hold time 

per channel in  

4 levels adjustable: 

0.1 s; 4.5 min; 2 h; 

 

Alignment 

automatically after switch-on of power 

supply, after pushing reset switch 

Output 

floating relay contact 

U

max

 = 250 V, I

max

 = 2 A,  

P

max 

= 60 W (ohm resistive load) 

Displays 

LED red = loop failure, 

LED green = detection, 

LED yellow = blinking when  

alignment / power 

Safety circuit 
loop input 

galvanic separation by transmitter,  

glow lamp

 

 

2.5 Dimensions  

(in mm) 

 
 
 
 
 
 

 

68

 

75

 

Socket 

71

28

 

89 

79

 

37

 

Measurements  
are subject to  
manufacturer’s  
tolerances!

 

 

 

2.6 Pin connection 

 

Standard model 315/2 SV /ST * 

 

 
 
 
 
 
 

 

 
 
Special model  

315/2 WV / WT * 

 

 

 

 

315/2 STV / STT * 

 
 
 
 
 
 
 

 

N.C. = not connected 
U

= power supply device *

 

Contact position: Detector on, loop not occupied 
 
* indicated on right label of device 

3 Relay B (Impulse) 

5 Relay A 

  

9 = N.C. 

11 = N.C. 

Loop

 

U

N

 

10

 

11 

9 = N.C. 

Loop 1 

2 U

N

 

5 Relay A 

10

3 Relay B (Impulse) 

11 fault report 

5 Relay A 

9 = N.C. 

Loop 1 

U

N

 

10 

3 Relay B (Impulse) 