Troubleshooting
Problem
Cause
Remedy
Cutting insert is causing a
“step” during facing.
The tube has been fed
too far into the tool or the
battery is almost completely
discharged.
Take tube out of the tool and
disassemble the tool holder.
Remove chips using pliers. File down
the step.
Slowly advance the cutting insert
towards the tube during new cutting.
Cutting insert or tool holder
is loose.
Tighten the cutting insert or the tool
holder.
Cutting insert does not rotate.
Battery completely
discharged.
Charge battery (refer to attached
operating instructions of the charger).
Use spare battery.
Battery not inserted properly Completely remove the battery and then
reinsert.
Breakaway nut has broken.
Replace the breakaway nut. See
Maintenance
.
The motor is not running but
the signal indicator lights up.
Quick flashing light -
The restart inhibitor has
activated.
Switch the tool off and back on. For
safety reasons, the tool will not restart
automatically after a power failure.
Slow flashing light - The
carbon brushes are worn
out.
Have the carbon brushes replaced by
your authorized Swagelok sales and
service representative.
Constant light - The motor
has overheated.
Unplug the tool and allow it to cool.
Tool has excessive vibration.
Speed is too high.
Reduce the speed.
Axial or radial play in the
components.
Check that the collet set is properly
secured.
Cutting insert is loose.
Tighten the cutting insert.
The finished tube face is not
smooth or has a large burr.
Cutting insert is worn.
Replace the cutting insert.