Installation 

 

CAUTION 
Do not use the regulator as a shutoff device. A level of leakage across the regulator seat can 
occur during normal operation. 

 

Points of Attention Before Installation 

This regulator can be equipped with a variety of different options. Before installing the regulator you should 
fully understand the functions of the supplied options and the suitability of your particular regulator for the 
intended application. 

The preferred mounting position of the regulator is horizontal with the spring housing facing upwards per 
Fig 2. Alternative mounting positions may increase the risk of component wear. 

It may be necessary to remove the regulator from the system during maintenance or service. Ensure that 
this is possible. 

The regulator is suitable for gases or liquids. Ensure compatibility between the regulator

’s materials of 

construction and the system media. 

 

Installation 

Verify that the regulator, its connections, and any accessories are undamaged. 

Verify that the regulator and any accessories are suitable for the system operating pressure and 
temperature and have suitable connections. 

At the time of delivery any gauge ports may be plugged with blind fittings. Remove these and connect 
gauges if desired. 

 

CAUTION 
Ensure all upstream tubing/pipework is clean and free from debris. Any swarf, lint, wire, etc. may 
damage the regulator, resulting in a seat leak. 

 

Verify the flow direction of the system and mount the regulator accordingly. 

Securely make the appropriate connections to the regulator in accordance with the procedures 
recommended by the connection manufacturer. 

Ensure that the tubing/pipework and the regulator are adequately supported and that there is no stress on 
the connections. 

Upstream and downstream shutoff valves should be installed in the system to facilitate servicing, 
maintenance, and troubleshooting of the regulator. 

 

Содержание PRS4

Страница 1: ...PRS4 and PRS8 Pressure Reducing Regulator User Manual Read the complete manual before installing and using the regulator...

Страница 2: ...dia should be free of excessive moisture to prevent icing at high flow Always wear the appropriate protective clothing including safety glasses gloves etc if required Follow the applicable safety and...

Страница 3: ...Operation 6 Points of Attention Before Operation 6 Adjusting the Set Pressure 6 Maintenance 7 Required Tools for Maintenance 7 Points of Attention Before Removal from the System 8 Removal from the Sys...

Страница 4: ...oduct failure Standard Features Threaded construction Stainless steel as standard Fully serviceable Diaphragm sensing Bottom mounting Additional Options The regulator is available with the following o...

Страница 5: ...s materials of construction and the system media Installation Verify that the regulator its connections and any accessories are undamaged Verify that the regulator and any accessories are suitable for...

Страница 6: ...sure may result in a fall of the outlet pressure This is usually referred to as inlet dependency or Supply Pressure Effect SPE This phenomenon does not indicate a problem with the regulator Adjusting...

Страница 7: ...ng or normal operation Swagelok recommends having maintenance kits readily available on site The need for maintenance kits is particularly important during the commissioning phase of a system installa...

Страница 8: ...or toxic If required take the necessary safety precautions to ensure a safe workspace and your personal safety CAUTION The product can be hot or cold depending on the environmental temperature and the...

Страница 9: ...ide C1 12 Washer C1 13 Hex nut C1 3 7 5 14 Clamp ring C1 15 Set spring C1 C4 16 Spring guide C1 Lubricate central recess 17 Ball C1 Lubricate 18 Spring housing N A 37 50 Lubricate threads 19 C ring D1...

Страница 10: ...10 PRS4 Series Exploded View Fig 1...

Страница 11: ...11 PRS4 Series Section View Fig 2...

Страница 12: ...12 PRS8 Series Exploded View Fig 3...

Страница 13: ...13 PRS8 Series Section View Fig 4...

Страница 14: ...e 11 6a PRS4 series Remove the seat retainer 8 using the seat retainer insertion tool Remove the seat 7 seat O ring 6 poppet 5 and poppet spring 3 from the body 1 6b PRS8 series Remove the seat retain...

Страница 15: ...guide 11 12 Lightly lubricate the spring housing threads 18 and screw it onto the body 1 Torque to 37 lbf ft 50 N m PRS8 Series 1 Secure the body 1 in a vise 2 Fit the poppet O ring 4 onto the poppet...

Страница 16: ...ly 14 5 psig 1 bar on the regulator and close the downstream shutoff valve 4 Monitor the outlet pressure An increase in pressure over time indicates a seat leak 5 Repeat the procedure with the highest...

Страница 17: ...er than the desired set pressure The outlet pressure rises too much when going from a dynamic to a static situation There is too much flow in the dynamic situation A larger regulator or parallel regul...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...e Swagelok Limited Lifetime Warranty For a copy visit swagelok com or contact your authorized Swagelok representative Swagelok Snoop TM Swagelok Company Loctite TM Henkel Corp Krytox TM The Chemours C...

Отзывы: