7.3.5
PLC/Logical Operation on Inputs
The logic input combines trigger signals with Boolean algorithms. The
camera provides AND, NAND, OR, NOR as below. You might connect
2 signals on the logic input. The result can be connected to a camera
trigger signal or it may be source for the next logical operation with
another input. It is possible to connect it to an OUT line as well.
AND
Both trigger inputs have to be true.
A
B
Y = A
∧
B
0
0
0
0
1
0
1
0
0
1
1
1
NAND
The
N E G AT IV E
-AND
is true only if its inputs are false.
Invert the output of the AND module.
A
B
Y = A NAND B
0
0
1
0
1
1
1
0
1
1
1