SVS-VISTEK
Feature-Set
79
7.3.3
Sequencer
The sequencer is used when different exposure settings and illuminations
are needed in a row.
E.g. the scenario to be captured may occur in three different versions and
should therefore be recorded with three different light source settings.
Each scenario/interval needs different illumination and exposure time.
The Sequencer allows not only detecting which scenario just appeared.
Depending on the scenario there will be one optimal image for further
analyzes.
Values to set
Unit
Description
Sequencer Interval
µs
Duration of the Interval
Exposure Start
µs
Exposure delay after Interval start
Exposure Stop
µs
Exposure Stop related to Interval Start
Strobe Start
µs
Strobe delay after Interval start
Strobe Stop
µs
Strobe Stop related to Interval Start
PWM Frequency
T
Basic duty cycle ( 1 / Hz ) for PWM
PWM Line 1
%
Demodulation Result
PWM Line 2
%
Demodulation Result
PWM Line 3
%
Demodulation Result
PWM Line 4
%
Demodulation Result
Values can be set for every scenario/interval
When setting “Exposure Start” and “Stop” consider ‘read-out-time’. It has
to be within the Sequencer Interval.
>
Trigger Input can be set with the 4IO feature set
>
For pysikal trigger input refer to pinout or
>
After trigger signal all programmed Interval will start.
>
Up to 16 Intervals can be programmed.
Sequencer settings can be saved to EPROM or to desktop
Содержание eco4050TR
Страница 1: ...3 23 2017 Manual EVO Tracer series evo1050TR evo2050TR evo2150TR eco4050TR evo4070TR evo8051TR ...
Страница 15: ...SVS VISTEK Getting Started 15 Installation will proceed 8 Installation completed ...
Страница 17: ...SVS VISTEK Getting Started 17 Conform to GenICam all control features will be listed in a flat tree diagram ...
Страница 21: ...SVS VISTEK Getting Started 21 4 7 Driver Circuit Schematics Figure 6 basic Illustration of driver circuit ...
Страница 32: ...SVS VISTEK Connectors 32 ...
Страница 36: ...SVS VISTEK Dimensions 36 ...
Страница 37: ...SVS VISTEK Dimensions 37 ...
Страница 78: ...SVS VISTEK Feature Set 78 Strobe Control Example Setup Figure 73 Illustration of an application using the 4IO ...
Страница 131: ...SVS VISTEK Troubleshooting 131 Space for further descriptions screenshots and log files ...