SVS-VISTEK
Manual SHR series
Feature-Set
5.02.2017
6.2.4
System Clock Frequency
Default system clock frequency in almost every SVCam is set to 66.6
MHz. To validate your system frequency: refer to:
Using the system clock as reference of time, time settings can only be
made in multiples of 15 ns.
𝑡
=
1
66. 6
�
𝑀𝑀𝑀
=
1
66 666 666. 6
�
1
𝑠
= 15
∙
10
−9
𝑠
= 15
𝑛𝑠
NOTICE
Use multiples of 15 ns to write durations into camera
memory
6.2.5
Temperature Sensor
A temperature sensor is installed on the mainboard of the camera.
To avoid overheating, the temperature is constantly monitored and read.
Besides software monitoring, the camera indicates high temperature by a
red flashing LED. (See flashing LED codes)