SV 258 PRO User Manual
46
6
SV 258 PRO MONITORING STATION TECHNICAL DATA
1
Nr
Parameter
Value/ Description
Physical data
1
Dimensions
SM 258 PRO
– 300 x 260 x 190 mm
SA 250
– 450 x 400 x 155 mm
2
Weight
SM 258 PRO
– ~10 kg
SA 250
– ~4 kg
3
Leakproof
classification
SM 258 PRO
– IP67 according to EN 60529 (1997) + A1 (2000)
4
Working temperature
range
-30
C do +60
C (Ambient air temperature, without direct sunlight).
Note: Outside this range the station will automatically switch itself off.
Note: In charging mode the range of working temperature is: -20
C to
+50
C !
5
Storage temperature
range
SM 258 PRO and SA 250: -40
C to +70
C
6
Working relative
humidity range
0
– 100 %RH
Power Supply
7
Internal battery
Europower EP 17-12 (12 V, 17 Ah)
8
SV 258 PRO power
consumption without
charging
Modem is switched off:
~1,2W
Mean infrequent short transmissions: ~1,8W
Continuous transmission:
~2,2W
9
Operating time when
powered from the
internal battery, (20
C,
17 Ah, fully charged)
Modem is switched off:
~170h (~7d)
Mean infrequent short transmissions: ~110h (~4,5d)
Continuous transmission:
~90h (~4d)
10
SV 258 PRO power
consumption including
charging
up to 30W ±5%
1
Our Company’s policy is based upon continuous product development and innovation. Therefore, we
reserve the right to change the specifications without any prior notice whatsoever