SVAN 973 User Manual
70
LEQ detector
Following LEQ detectors are available in the instrument:
Imp.
,
Fast
and
Slow
.
Dosimeter
specific parameters can be set in accordance with the OSHA HC
(Occupational Safety and Health Administration - Hearing Conversation),
OSHA PEL (Occupational Safety and Health Administration
– Permissible
Exposure Level) and ACGIH standards.
Criterion Level
is a
steady noise level permitted for a full eight-hour work shift
:
60dB
,
65dB
,
70dB
,
75dB
,
80dB
,
84dB
,
85dB
,
87dB
,
90dB
;
Threshold Level
is a
noise level limit below which the dosimeter does not
accumulate noise dose data
:
None
,
60dB
,
65dB
,
70dB
,
75dB
,
80dB
,
85dB
,
90dB
;
Exchange Rate
is an
amount by which the permitted sound level may increase if
the exposure time is halved
:
2
,
3
,
4
,
5
,
6
;
ULT Threshold Level
(Upper Level Time)
is a threshold level for calculation of
the ULT results:
70dB
÷
140dB
;
PTC Threshold Level
(Peak Threshold Counter) is a threshold level for
calculation of the PTC results:
70dB
÷
140dB
.
11.4 C
HECKING MEASUREMENT RANGE
–
R
ANGE
The measurement range for the
Dosimeter
function is
50.0 LEQ(A)
– 141.0 PEAK. The detailed description of
the measurement range parameters is given in
Appendix C.
The calibration factor is always added to the lower and
upper range level.
<ENT>
11.5 S
ETTING EXPOSURE TIME
–
E
XPOSURE
T
IME
The
Exp. Time
enables setting the desired value of the
workday exposure time which is used for calculation of
the
LEPd
results (see Appendix D).
<ENT>
11.6 S
ETTING ALARM THRESHOLDS FOR DOSE METER RESULTS
–
A
LARM
The
Alarm
position is active only in the
Dosimeter
function and enables programming the alarm thresholds
for three profiles (
Thresh. P1 (2,3)
).
Thresholds can be set for next measurement results of
the
Dosimeter
in ranges:
DOSE
: 1÷200%;
<ENT>
D_8h
: 1÷200%;
PTC
: 1÷1000;
ULT
: 1÷60s.
If
Off
is selected, the alarm for the measurement result is
switched off.
<ENT>
Содержание SV 973
Страница 157: ...SVAN 973 User Manual Appendixes 157 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 158: ...SVAN 973 User Manual Appendixes 158 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 159: ...SVAN 973 User Manual Appendixes 159 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 172: ...SVAN 973 User Manual Appendixes 172 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 173: ...SVAN 973 User Manual Appendixes 173 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 174: ...SVAN 973 User Manual Appendixes 174 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 185: ...SVAN 973 User Manual Appendixes 185 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...
Страница 192: ...SVAN 973 User Manual Appendixes 192 LF filter according to EPA 93 F105 02 104 Low Frequency Noise Control Regulations...