![Svantek SV 104BIS Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/svantek/sv-104bis/sv-104bis_user-manual_1409257033.webp)
33
SV
104BIS User Manual
4
RUNNING AND OPERATING BASIC PROCEDURES
4.1
C
HARGING
SV 104BIS
SV 104BIS can be charged only with the use of docking station for a single unit (1-bay docking station
SB 104B-1
) or for five units (5-bays docking station
SB 104B-5
).
Both docking stations are equipped with the USB Type B connector and can be connected with a PC for data
transfer with the
SC 16
cable. SB 104B-1 is also powered via the USB port whilst SB 104B-5 is powered by
the
SB 33
power supply (9V AC/DC).
Figure 4-1
1-bay and 5-bay docking station (SB 104B-1 and SB 104B-5)
To charge SV 104BIS place it onto the docking station charger and ensure the power cable is connected.
SV 104BIS will automatically turn on the display during charging and present how much charge is within the
instrument. SV 104BIS will
display ‘
Charging completed
’ once charging is complete
d. This should take
approximately 7 hours from a fully discharged state. A charging time of about 2 hours will be sufficient to
perform greater than 10 hours of measurement. A fully charged instrument holds enough charge to run for
approximately 45 hours.
Note that once disconnected from the docking station, the dosimeter will automatically switch off. If put again
onto the docking station the internal battery is float charged. This keeps the battery performance in steady
condition. If the battery is fully discharged prior to being placed on a charger, it trickles charges for a maximum
1h time prior to the fast charge cycle, this prevents damage to the batteries.
Docking stations are equipped with the LED. Table below describes LED statuses of the Docking Station.
Charger LED status indication
Description
SB 104B-1
OFF
Dock station is not powered on
GREEN
Indicates the
dock station is powered on and fully operational
RED
Dock station is powered on, but not fully operational
RED flashing quickly,
2 times per second
Charging error
–
ambient air temperature limit exceeded
SB 104B-5
LED on the top
OFF
Dock station is not powered on
GREEN
Indicates the
dock station is powered on and fully operational
RED
Dock station is powered on, but not fully operational
SB 104B-5
LED on the side
RED flashing quickly,
2 times per second
Charging error
–
ambient air temperature limit exceeded
Table 4-1
Docking station LED status description
Содержание SV 104BIS
Страница 139: ...139 SV104BIS User Manual 250 Hz 315 Hz 400 Hz 500 Hz...
Страница 140: ...140 SV104BIS User Manual 630 Hz 800 Hz 1000 Hz 1250 Hz...
Страница 141: ...141 SV104BIS User Manual 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 142: ...142 SV104BIS User Manual 2800 Hz 3150 Hz 3550 Hz 4000 Hz...
Страница 143: ...143 SV104BIS User Manual 4500 Hz 5000 Hz 5600 Hz 6300 Hz...
Страница 144: ...144 SV104BIS User Manual 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Страница 148: ...148 SV104BIS User Manual Figure C 4 Total directional characteristics asymmetrical axis...
Страница 150: ...150 SV104BIS User Manual 630 Hz 800 Hz 1000 Hz 1250 Hz...
Страница 151: ...151 SV104BIS User Manual 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 152: ...152 SV104BIS User Manual 2800 Hz 3150 Hz 3550 Hz 4000 Hz...
Страница 153: ...153 SV104BIS User Manual 4500 Hz 5000 Hz 5600 Hz 6300 Hz...
Страница 154: ...154 SV104BIS User Manual 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Страница 161: ...161 SV104BIS User Manual 1 0 kHz 1 1 octave filter 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...
Страница 162: ...162 SV104BIS User Manual 125 Hz 1 1 octave filter 63 0 Hz 1 1 octave filter 31 5 Hz 1 1 octave filter...
Страница 166: ...166 SV104BIS User Manual 1 3 octave filters for 16 0 Hz 1 1 octave filter...
Страница 180: ...180 SV104BIS User Manual...