YH4
GRAND
VITARA
7E-12
DIFFERENTIAL (FRONT)
1. Pump assembly
Air Pump Assembly
Removal / Installation
1) Disconnect air hoses and coupler from air pump assembly.
2) Remove pump assembly by removing bolts.
3) Reverse removal procedure for installation.
Tightening Torque
(a): 13 N
.
m (1.3 kg-m, 9.5 lb-ft)
Inspection
1) Install special tool, voltmeter and battery to pump assembly as
shown in figure.
2) Tighten adjusting screw of special tool as far as it stops and
close its air check side opening by using fuel hose as blind plug.
Special Tool
(A): 09918-18110
3) Check that motor starts to run (a sound can be heard) when bat-
tery is connected and it stops when specified pressure is ob-
tained.
Check also for air leakage.
Specified pressure: 30.0 – 45.0 kPa
(0.30 – 0.45 kg / cm
2
, 4.25 – 6.40 psi)
4) Check that value indicated on voltmeter is within specification
shown below.
When motor is running: 0 – 1 V
When motor has stopped running: 10 – 14 V
CAUTION:
Do not run motor more than 10 seconds continuously to
prevent motor breakage.
Содержание Grand Vitara 1998
Страница 1: ...SUZUKI SQ 416 420 625 M Y 1998 2005 SERVICE MANUAL VOLUME 1 CHASSIS SECTIONS ELECTRICAL BODY SECTIONS ...
Страница 225: ...YH4 GRAND VITARA FRONT SUSPENSION 3D 23 TIGHTENING TORQUE SPECIFICATIONS ...
Страница 531: ...YH4 GRAND VITARA 8 6 BODY ELECTRICAL SYSTEM POWER SUPPLY DIAGRAM Refer to Section 8A ...
Страница 642: ...YH4 GRAND VITARA 9 24 BODY SERVICE 1 Rear bumper 2 Rear bumper screws 3 Rear bumper member REAR BUMPER ...
Страница 659: ...YH4 GRAND VITARA BODY SERVICE 9 41 1 Side body outer panel A Apply sealant B Brush treatment ...
Страница 673: ...YH4 GRAND VITARA BODY SERVICE 9 55 B B C C 2 DOOR MODEL ...