SERVICING INFORMATION 11-13
BATTERY
Complaint
Symptom and possible causes
Remedy
“Sulfation”, acidic
white powdery sub-
stance or spots on
surfaces of cell
plates.
1. Cracked battery case.
2. Battery has been left in a run-down condition for a long
time.
Replace the battery.
Replace the battery.
Battery runs down
quickly.
1. Trouble in charging system.
2. Cell plates have lost much of their active material as a
result of overcharging.
3. Internal short-circuit in the battery.
4. Too low battery voltage.
5. Too old battery.
Check the generator, regula-
tor/rectifier and circuit connec-
tions and make necessary
adjustments to obtain specified
charging operation.
Replace the battery, and cor-
rect the charging system.
Replace the battery.
Recharge the battery fully.
Replace the battery.
Battery “sulfation”.
1. Incorrect charging rate.
(When not in use battery should be checked at least
once a month to avoid sulfation.)
2. The battery was left unused in a cold climate for too
long.
Replace the battery.
Replace the battery if badly
sulfated.
Содержание AN650 2002
Страница 1: ......
Страница 47: ...PERIODIC MAINTENANCE 2 29 ...
Страница 124: ...ENGINE 3 73 POSITION OF CAMSHAFTS AND SPROCKETS 15 1 1 2 2 3 3 ...
Страница 137: ...CVT 5 3 Remove the CVT mounting bolts Remove the CVT assembly ...
Страница 177: ...6 16 FI SYSTEM CVT SYSTEM E Serial communication G Speed signal Speed sensor H Engine rpm Crankshaft position sensor ...
Страница 425: ...SERVICING INFORMATION 11 21 FUEL TANK MOUNTING ...
Страница 426: ...11 22 SERVICING INFORMATION FUEL TANK MOUNTING Only for E 28 ...
Страница 427: ...SERVICING INFORMATION 11 23 FUEL TANK HOSE ROUTING Clamp Orange Black Gray Black 5 8 mm 5 8 mm 5 mm TPC valve TPC valve ...
Страница 462: ...Prepared by July 2002 Part No 99500 36110 01E Printed in Japan 464 ...
Страница 463: ......