11-12 SERVICING INFORMATION
ELECTRICAL
Complaint
Symptom and possible causes
Remedy
No sparking or poor
sparking.
1. Defective ignition coil/plug cap or camshaft position
sensor.
2. Defective spark plugs.
3. Defective generator.
4. Defective ECM.
5. Defective tip over sensor.
6. Open-circuited wiring connections.
Replace.
Replace.
Replace.
Replace.
Replace.
Check and repair.
Spark plugs soon
become fouled with
carbon.
1. Mixture too rich.
2. Idling speed set too high.
3. Incorrect gasoline.
4. Dirty air cleaner element.
5. Too cold spark plugs.
Consult FI system.
Adjust fast idle or throttle stop
screw.
Change.
Clean or replace.
Replace with hot type plugs.
Spark plugs become
fouled too soon.
1. Worn piston rings.
2. Worn piston or cylinders.
3. Excessive clearance of valve stems in valve guides.
4. Worn stem oil seal.
Replace.
Replace.
Replace.
Replace.
Spark plug electrodes
overheat or burn.
1. Too hot spark plugs.
2. Overheated the engine.
3. Loose spark plugs.
4. Too lean mixture.
Replace with cold type plugs.
Tune up.
Retighten.
Consult FI system.
Generator does not
charge.
1. Open- or short-circuited lead wires, or loose lead con-
nections.
2. Short-circuited, grounded or open generator coils.
3. Short-circuited or panctured regulator/rectifiers.
Repair or replace or retighten.
Replace.
Replace.
Generator does
charge, but charging
rate is below the
specification.
1. Lead wires tend to get short- or open-circuited or
loosely connected at terminals.
2. Grounded or open-circuited stator coils or generator.
3. Defective regulator/rectifier.
4. Defective cell plates in the battery.
Repair or retighten.
Replace.
Replace.
Replace the battery.
Generator over-
charges.
1. Internal short-circuit in the battery.
2. Damaged or defective resistor element in the regulator/
rectifier.
3. Poorly grounded regulator/rectifier.
Replace the battery.
Replace.
Clean and tighten ground con-
nection.
Unstable charging.
1. Lead wire insulation frayed due to vibration, resulting in
intermittent short-circuiting.
2. Internally short-circuited generator.
3. Defective regulator/rectifier.
Repair or replace.
Replace.
Replace.
Starter button is not
effective.
1. Run down battery.
2. Defective switch contacts.
3. Brushes not seating properly on starter motor commu-
tator.
4. Defective starter relay or starter interlock switch.
5. Defective main fuse.
Repair or replace.
Replace.
Repair or replace.
Replace.
Replace.
Содержание AN650 2002
Страница 1: ......
Страница 47: ...PERIODIC MAINTENANCE 2 29 ...
Страница 124: ...ENGINE 3 73 POSITION OF CAMSHAFTS AND SPROCKETS 15 1 1 2 2 3 3 ...
Страница 137: ...CVT 5 3 Remove the CVT mounting bolts Remove the CVT assembly ...
Страница 177: ...6 16 FI SYSTEM CVT SYSTEM E Serial communication G Speed signal Speed sensor H Engine rpm Crankshaft position sensor ...
Страница 425: ...SERVICING INFORMATION 11 21 FUEL TANK MOUNTING ...
Страница 426: ...11 22 SERVICING INFORMATION FUEL TANK MOUNTING Only for E 28 ...
Страница 427: ...SERVICING INFORMATION 11 23 FUEL TANK HOSE ROUTING Clamp Orange Black Gray Black 5 8 mm 5 8 mm 5 mm TPC valve TPC valve ...
Страница 462: ...Prepared by July 2002 Part No 99500 36110 01E Printed in Japan 464 ...
Страница 463: ......