background image

User Manual

TesiMod Touch Panel TP22

Part Number:

80 860.545

Version:

2

Date:

09.12.2005

Valid for:

TP22EM
TP22ES
TP22ET

Содержание TesiMod TP22

Страница 1: ...User Manual TesiMod Touch Panel TP22 Part Number 80 860 545 Version 2 Date 09 12 2005 Valid for TP22EM TP22ES TP22ET...

Страница 2: ...eprocessed 2 9 12 2005 Technical data of displays revised This manual including all illustrations contained herein is copyright protected Use of this manual by any third party in departure from the co...

Страница 3: ...us Device 2 5 2 3 Connecting the Device 2 6 2 3 1 Supply Voltage 24 V 2 6 2 4 Switching the Device on 2 8 2 5 Identification 2 8 3 Control and Display Elements 3 1 3 1 Keyboard 3 1 3 1 1 Function Keys...

Страница 4: ...n Assignment 4 15 4 2 3 2 Cable 4 15 4 2 3 3 Diagnostic 4 16 4 2 4 INTERBUS OPC LWL DO1 DI1 DO2 DI2 4 17 4 2 4 1 Connector Pin Assignment 4 18 4 2 4 2 Cable 4 18 4 2 4 3 Diagnostic 4 18 4 2 5 MPI X2 4...

Страница 5: ...iii Overall Table of Contents 7 Ordering Data 7 1 A Index A 1...

Страница 6: ...Overall Table of Contents 1 iv...

Страница 7: ...jury or even up to the death of the operator Danger This symbol is used to refer to instructions which if ignored or not carefully followed could result in personal injury Note This symbol indicates a...

Страница 8: ...ce is state of the art and has been built to the latest standard safety re quirements However dangerous situations or damage to the machine itself or other property can arise from the use of this devi...

Страница 9: ...315 1 Insert the operating device from the front through the mounting cutout 2 Fasten the operating device using hexagon nuts When installing the operating device keep a minimum clearance of 30 mm 1...

Страница 10: ...Installation and Commissioning 2 2 2 2 1 Front Panel Dimensions Figure 2 1 Front panel dimensions...

Страница 11: ...2 3 Installation and Commissioning 2 2 2 Mounting Cutout Figure 2 2 Mounting cutout A Mounting Cutout B Front Panel...

Страница 12: ...ice Figure 2 3 Side view and mounting depth for the standard device 1 Front Panel 2 Circumferential Seal 3 Press in Threaded Bolt M4 x 18 mm 0 709 4 Mounting Surface Thickness 1 mm to 8 mm 0 039 to 0...

Страница 13: ...Side view and mounting depth for the field bus device 1 Front Panel 2 Circumferential Seal 3 Press in Threaded Bolt M4 x 18 mm 0 709 4 Mounting Surface Thickness 1 mm to 8 mm 0 039 to 0 315 5 Spring L...

Страница 14: ...A suitable female connector strip of the type Phoenix COMBICON MSTB 2 5 3 STF is supplied Use the following procedure to connect the device to the supply voltage 1 Strip approx 30 mm 1 181 off the out...

Страница 15: ...onnector strip is plugged on 4 Secure the female connector strip in place with a screw type locking to prevent it from slipping out If shielded connecting cables are used in the supply voltage area th...

Страница 16: ...idance When you touch the display while the Start mask is displayed the Setup mask ap pears In this mask you define the parameters for the interfaces and the operating device 2 5 Identification You ca...

Страница 17: ...ciple of the keys in the programming software Figure 3 1 Front view 1 Function Keys F1 to F5 2 Status LED Help 3 Status LED Edit 4 Display 5 Device Designation 3 1 1 Function Keys The function of the...

Страница 18: ...am ages of the touch screen Exclusively therefore use the fingertips or the aids indi cated in the technical data for the operation To protect the touch screen you can use special protection foils You...

Страница 19: ...he display is damaged avoid touching swallowing or breathing in the liquids or gases which may leak out Danger Corrosive If the display is damaged avoid touching swallowing or breathing in the liquids...

Страница 20: ...lt value To restore the default contrast brightness 1 Switch the device off 2 Set the switches S1 and S4 of the user mode switch to ON 3 Switch the device on again 4 When the warning appears switch th...

Страница 21: ...e upload download logging printer scan ner SER2 For the communication channel SER1 the protocol specific use only allows one of the three interface standards to be used Depending on the device variant...

Страница 22: ...w 2 Cable Fastener for Battery 3 Seal 4 Front Panel 5 Mounting Bolt 6 Nameplate 7 Threaded Bolt for Protective Grounding 8 Connector X1 A Supply Voltage 9 Reset Key 10 User Mode Switch 11 Female Conne...

Страница 23: ...Current Flow 20 mA Signal Logic 0 Current Flow Interrupted Table 4 2 Pin assignment TTY 20 mA passive Pin Designation Function 10 T Transmitted Data Positive Polarity 13 R Received Data Positive Polar...

Страница 24: ...ure 4 3 25 pin D SUB female connector strip Connector in the operating terminal 25 pin D SUB female connector Signal Logic 1 UA UB 0 3 V i e UA UB Signal Logic 0 UA UB 0 3 V i e UA UB Table 4 4 Pin as...

Страница 25: ...m termination RS422 RS485 Legend for table I Switch ON Switch OFF Table 4 5 Resistor values termination RS422 RS485 Designation Value R1 R3 510 Ohm R2 150 Ohm R4 120 Ohm The switch positions for ON or...

Страница 26: ...pin D SUB female connector strip 4 1 3 2 Termination Table 4 7 Pin assignment RS232 Pin Designation Function 6 TD Transmitted Data 15 CTS Clear to Send 17 RTS Request to Send 18 RD Received Data 25 S...

Страница 27: ...gnment Figure 4 6 25 pin D SUB female connector strip Connector in the operating device 25 pin D SUB female connector strip Table 4 8 Pin assignment RS232 Pin Designation Function 1 Low Noise Ground 2...

Страница 28: ...d Bus Interfaces 4 2 1 CAN X2 1 X2 2 The opto decoupled interface for CAN bus connections is available to integrate the device into a CAN structure The CAN bus is a high speed bus in accordance with I...

Страница 29: ...le connector strip Connector in the terminal 9 pin D SUB male and female connector strip assignment for male and female connector strip is the same All signal lines are looped through from X2 1 to X2...

Страница 30: ...agnostics LED at the operating device has the following functions A shielded twisted pair cable cable type LiYCY TP complying with ISO 11898 must be used Table 4 10 Cable characteristics CAN Parameter...

Страница 31: ...ce 4 2 2 DeviceNet X2 1 X2 2 The opto decoupled interfaces are available to integrate the device into a CAN struc ture The CAN bus is designed as a high speed bus in accordance with ISO DIS 11898 Figu...

Страница 32: ...male connector strip Connector in the terminal 9 pin D SUB male and female connector strip assignment for male and female connector strip is the same All signal lines are looped through from X2 1 to X...

Страница 33: ...of the bus system Figure 4 12 Arrangement of the DeviceNet diagnostics LED The diagnostics LED at the operating device has the following functions A DeviceNet certified cable must be used Table 4 14...

Страница 34: ...Battery 3 Seal 4 Front Panel 5 Mounting Bolt 6 Nameplate 7 Threaded Bolt for Protective Grounding 8 Connector X1 A Supply Voltage 9 Reset Key 10 User Mode Switch 11 Assignment Connector X2 1 Remote Bu...

Страница 35: ...Connected 5 nc Not Connected 6 DO Data Input Inverted 7 DI Data Output Inverted 8 nc Not Connected 9 nc Not Connected Table 4 18 Pin assignment remote bus out INTERBUS Pin Designation Function 1 DO D...

Страница 36: ...e 4 15 Arrangement of the INTERBUS diagnostics LEDs The diagnostics LEDs at the operating device has the following functions Table 4 19 Functions of the INTERBUS diagnostics LEDs Designation Color Sta...

Страница 37: ...astener for Battery 3 Seal 4 Front Panel 5 Mounting Bolt 6 Nameplate 7 Threaded Bolt for Protective Grounding 8 Connector X1 A Supply Voltage 9 Optical Fiber Interface DO1 Remote Bus In 10 Reset Key 1...

Страница 38: ...f the INTERBUS OPC LWL diagnostics LEDs The diagnostics LEDs at the operating device has the following functions Never look directly into the open end of an optical fiber cable Infrared light can caus...

Страница 39: ...e Off PCP Not Active FO1 Yel low On Incoming Optical Fiber Path Not OK Off Incoming Optical Fiber Path OK FO2 Yel low On Outgoing Optical Fiber Path Not OK Off Outgoing Optical Fiber Path OK Table 4 2...

Страница 40: ...ar View MPI 1 Fastening Screw 2 Cable Fastener for Battery 3 Seal 4 Front Panel 5 Mounting Bolt 6 Nameplate 7 Threaded Bolt for Protective Grounding 8 Connector X1 A Supply Voltage 9 Reset Key 10 User...

Страница 41: ...nation Function 1 nc Not Connected 2 nc Not Connected 3 RxD TxD P Received Data Transmitted Data Plus 4 CNTR P Repeater Control Signal Plus 5 DGND Data Transmission Potential 6 VP Supply Voltage of Te...

Страница 42: ...e operating device The LED shows a state of the bus system Figure 4 20 Arrangement of the MPI diagnostics LED The diagnostics LED at the operating device has the following function Table 4 24 Function...

Страница 43: ...US DP 1 Fastening Screws 2 Cable Fastener for Battery 3 Seal 4 Front Panel 5 Mounting Bolt 6 Nameplate 7 Threaded Bolt for Protective Grounding 8 Connector X1 A Supply Voltage 9 Reset Key 10 User Mode...

Страница 44: ...nsmission Potential 6 VP Supply Voltage of Terminators Plus 7 nc Not Connected 8 RxD TxD N Received Data Transmitted Data Minus 9 CNTR N Repeater Control Signal Minus The D SUB connector strips must b...

Страница 45: ...is located on the rear of the operating device The LED shows the states of the bus system The diagnostics LED on the operating device has the following functions Table 4 28 Function of the PROFIBUS DP...

Страница 46: ...pactFlash card by the notches on each side of the card Figure 4 23 Rear view of the memory card 4 3 1 Inserting the Memory Card When you insert the card from the rear side of the operating device make...

Страница 47: ...6 Shielding D SUB connectors 1 D SUB connector 2 Shield 3 Cable clip 4 Cable The shield must be folded back into a flat position over the cable sheath When fastening the cable with the cable clip as m...

Страница 48: ...Interfaces of the Device 4 28...

Страница 49: ...plies the real time clock The minimum battery life is 5 years even under unfavorable operating condi tions When the battery runs down the message Change battery is generated au tomatically We recommen...

Страница 50: ...ector of the new battery 8 Disconnect the connector strip of the supply voltage 9 Use a cable fastener to attach the new battery to the enclosure 10 Place the rear panel back onto the device 11 Carefu...

Страница 51: ...posal body or a licensed battery dealer for recycling Only dispose of dead batteries in public or commercial collection boxes The battery is drained when the message Change battery appears on the disp...

Страница 52: ...Maintenance and Servicing 5 4...

Страница 53: ...ability No Damages or Malfunctions after 3 Million Keystrokes as the Following Keystroke Element R8 HS40 Silicon Rubber Keystroke Load 150 g Keystroke Frequency 3 Hz Display TP22EM TP22ES TP22ET Type...

Страница 54: ...rity Reversal Integrated Standard Interfaces Variable Baud Rates and Data Formats X3 SER1 TTY 20 mA According to CL 2 and DIN 66 348 T1 Transmission Length 0 1000 m 3280 84 ft Twisted Pair Shielded El...

Страница 55: ...TP22ES 3 MByte Flash TP22ET 7 MByte Flash RAM 512 KByte Static CMOS RAM Battery Backed Memory Card Option CompactFlash Card Connection System D SUB Female and Male Connector Strips 9 Pin and 25 Pin Fe...

Страница 56: ...60529 Impact Load Shocks EN 60068 Part 2 27 Sinusoidal Vibrations EN 60068 Part 2 6 Corrosion Protection IEC 60068 Enclosure and Front Panel Enclosure Steel Sheet Galvanized Front Panel Aluminium Var...

Страница 57: ...dapter for PC 81167 000 25 Pin Download Cable 88175 030 USB RS232 Converter for Download Only in Combination with 88175 030 81215 000 Protection Foil for Touch Screen 5 7 27288 000 Protection Foil for...

Страница 58: ...Ordering Data 7 2...

Страница 59: ...tandard device 2 4 Mounting depth for the field bus device 2 5 Display 3 3 F Firmware version 2 8 Function keys 3 1 Fuse 5 1 I Identification 2 8 Intended use 1 2 Interface CAN X2 1 X2 2 4 8 DeviceNet...

Страница 60: ...A 2 T Target group 1 2 Technical data 6 1 Termination CAN 4 10 DeviceNet 4 13 MPI 4 21 RS232 4 6 RS485 4 5 TTY 20 mA 4 3 Touch screen 3 2 U Unpacking 2 1 User mode switch 3 2...

Страница 61: ......

Страница 62: ...S tron electronic GmbH Kurze Stra e 29 D 70794 Filderstadt Phone 0049 711 77098 0 Fax 0049 711 77098 60 E mail doku suetron de Internet www suetron com...

Отзывы: