background image

  

  

 
 
 
 

 

 
 
 
 
 
 
 

FlavorShot-10 

Dispensers 

 

ACFS-10 

 

Operations Manual

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

D-19-007 Rev. A 

Содержание FlavorShot-10

Страница 1: ...FlavorShot 10 Dispensers ACFS 10 Operations Manual D 19 007 Rev A...

Страница 2: ...or Damage Uncrating the Dispenser Reshipment Installing the FlavorShot Dispenser Starting the FlavorShot Dispenser Install Fill the Flavor Tanks Prime Individual Pumps Remove Empty Flavor Tank Refill...

Страница 3: ...Schedule Maintenance General Tube Maintenance Check Valve Maintenance Troubleshooting Guide Wiring Diagram Warranty A C Dispensing Equipment Inc 100 Dispensing Way Lower Sackville NS Canada B4C 4H2 S...

Страница 4: ...4 Identification of Dispenser Components...

Страница 5: ...not immerse the dispenser in water Observe all safety precautions with this dispenser that you would with any electrical appliance FlavorShot dispensers deliver automatically controlled portions of l...

Страница 6: ...it up and off Remember not to lift the dispenser by the door 7 Remove the plastic protective covering from the stainless steel exterior of the dispenser by peeling it off To peel hold the dispenser fi...

Страница 7: ...nd open to ensure proper operation of the ventilation system and to prevent over heating and damage to the system Maintain an air space on all sides of the dispenser 5 Do not place the dispenser too c...

Страница 8: ...e row of dots it indicates that pump has failed to register For example Wait Indicates the pump for tank 6 is not registered and pump 6 will not dispense flavor See Troubleshooting Otherwise Wait indi...

Страница 9: ...the tank fits properly it will not lift easily out of the pump 5 Remove the tank cap and fill the tank with the appropriate flavor Fill the flavor tank to the Full line on the tank Press the Flavor bu...

Страница 10: ...press the individual flavor button 3 press the PRIME button and hold for 2 seconds The PRIME button is located at the bottom right of the button panel NOTE The PRIME function automatically tracks the...

Страница 11: ...ted on the bottom left of the button panel on the dispenser door 3 When the tank and pump are empty press the Clean button again to cancel the remainder of the clean cycle 4 Open the dispenser door an...

Страница 12: ...isplay Reset Full or Reset Low Fill Press the Reset button until Reset Full is displayed If you refill the tank to the Low level 1 Press the Flavor button for the tank filled 2 Press the Reset button...

Страница 13: ...ndow Reset button S small M medium L large XL xlarge modifier Flavors 1 2 3 4 5 Flavors 6 7 8 9 Combo button Clean button Prime button Note Infrared Programming Window used to reprogram dispense opera...

Страница 14: ...econds To check drink count data for a specialty drink 1 Press Prime button and hold for 2 seconds Release the Prime button 2 Press Clean button and hold for 2 seconds 3 Press the Flavor button for th...

Страница 15: ...egins to flash Once the indicator light begins to flash the tank can be refilled with a 750 ml bottle of flavor LOW LEVEL LOCKOUT After the low level indicator begins to flash and when approximately 1...

Страница 16: ...the appropriate buttons to select the product desired To make a coffee 1 choose a flavor 2 choose a size To make a specialty drink 1 choose a flavor 2 press modifier e g Latt 3 choose a size 3 The di...

Страница 17: ...sanitize 4 Remove the tube for the old flavor Pull both ends of the tube off the product dispensing block and the discharge barbs 5 Replace with the new tube Attach both ends of the tube to the produ...

Страница 18: ...ier selected Small S Medium M Large L indicates size selected Refill Tank Indicates tank must be filled to the Full line Reset Full indicates tank level is resetting to Full Reset Low Fill Indicates t...

Страница 19: ...re the cloth is used to wipe down the exterior surfaces of the dispenser CLEANING Dispenser Components Tanks and caps must be washed by hand or other means according to state regulations Flavor tanks...

Страница 20: ...ove them from the pump s 2 RINSE Rinse the tank s including the cap s with lukewarm water 3 WASH Place the tank s and cap s in a hot water wash at a minimum water temperature of 140 F or 60 C Add a go...

Страница 21: ...ap g Place the cleaned tank in the appropriate location on the tank pump shelf Before installing the tank apply a small amount of food grade lubricant to the O ring on the outlet at the bottom of the...

Страница 22: ...ill the tank with sanitizer Press the Flavor button for the tank to be sanitized Before the red light on the Flavor button goes out press and hold the Clean button for two seconds and allow the saniti...

Страница 23: ...at the location this step may be carried out by placing the tray in the dishwasher and washing on the pot cycle 4 RINSE After washing rinse the tray well with lukewarm water 5 SANITIZE Sanitize the t...

Страница 24: ...anitized brush and wipe clean with a clean sanitized towel clean catch tray rinse wash rinse sanitize and air dry Every 60 days clean all flavor tanks caps and pumps using the procedures above clean c...

Страница 25: ...y are not blocked cut cracked or disfigured Damaged tubes must be replaced To replace the tube Step Action 1 Remove the tube from the barbed fittings at both ends at the pump outlet and at the product...

Страница 26: ...side of the valve housing 3 Insert a new check valve in the proper orientation to direct flow with the input end facing the flavor tank and the output end facing the product dispensing block Replaceme...

Страница 27: ...ce 2 Make sure there is flavor product in the tanks 3 Make sure the dispensing tubes from the flavor tanks are clear of blockage with no twists or kinks and are not pinched off 4 Make sure the dispens...

Страница 28: ...uct may have run dry before refilling Complete a prime cycle See Step 9 page 10 4 Inlet check valve in the pump body below the tank spout may be bypassing and need to be replaced Replacement check val...

Страница 29: ...securely positioned in the pump 2 Check the O ring seal on the tank outlet to ensure that it is not damaged Replace if damaged NOTE Before installing an O ring apply a small amount of food grade lubr...

Страница 30: ...cing the dispense head d reattach the check valve housing making sure both O rings are still in place and turn the housing rotation to secure the fitting 4 Ensure the dispenser is level Use a bubble l...

Страница 31: ...1 902 865 9602 LCD display on the front door does not come on Check to make sure that the pumps are operating If so the LCD may be faulty If the pumps don t function and the LCD Display is not on the...

Страница 32: ...ch dispenser includes the contact telephone number for SureShot Solutions Refer to the Serial Number and the Model Number on the label when calling These numbers are crucial to helping us provide prom...

Страница 33: ...rred or service performed by its Authorized Service Agencies The use of other than A C Dispensing Equipment Inc Authorized Service Agencies will void this warranty and A C Dispensing Equipment Inc wil...

Страница 34: ...ill be strictly monitored Any parts that are used may be required to be returned to the manufacturer for examination with the signed field report outlining all work performed on the unit Any parts rep...

Страница 35: ...35...

Страница 36: ...36 A C Dispensing Equipment Inc 100 Dispensing Way Lower Sackville Nova Scotia B4C 4H2 Canada 1 888 777 9990 or 1 902 865 9602 www sureshotsolutions com...

Отзывы: