PRODUCTS
July 29, 2011 Rev: 1.2 No.974-9885
SERVICE AND MAINTENANCE MANUAL
PLEASE RETAIN FOR FUTURE REFERENCE
A Division of Haul-All Equipment Ltd.
4115 - 18 Avenue North
Lethbridge, Alberta T1H 5G1
www.sureflame.ca
CONSTRUCTION HEATERS
SE405
Страница 1: ...2011 Rev 1 2 No 974 9885 SERVICE AND MAINTENANCE MANUAL PLEASE RETAIN FOR FUTURE REFERENCE A Division of Haul All Equipment Ltd 4115 18 Avenue North Lethbridge AlbertaT1H5G1 www sureflame ca CONSTRUCT...
Страница 2: ...uld use or service this heater If you need assistance or heater information such as an instruction manual labels etc Contact the manufacturer Fire burn inhalation and explosion hazard Keep solid combu...
Страница 3: ...not be used in the home ANSI A119 2 NFPA 501C 1987 Recreational Vehicle Standard prohibits the installation or storage of LP Gas containers even temporarilyinsideanyrecreationalvehicle Thestandardals...
Страница 4: ...OR USED SE405 CONSTRUCTION HEATER CONTENTS Specifications 5 Installation 6 Installation Using A Propane Supply Tank 7 Installation For Natural Gas Applications 7 Operating Instructions 8 Preventative...
Страница 5: ...x6 Inlet Air Flow 1150 cfm 545 l s at 20 C 68 F Outlet Air Flow 1800 cfm 850 l s at 186 C 367 F Electrical Rating 120 volts 60 Hz 7 5 amps single phase Minimum Temperature 30 C 22 F Maximum Duct Lengt...
Страница 6: ...F Only duckwork supplied by the manufacture shall be use with this heater Alsomakesurethatnoflammablevapoursarepresentinthespacewhere the heater is being used 2 Whenconnectingtheheatertoanaturalgasorp...
Страница 7: ...off the propane supply valve at the container when the heater is not in use 5 The installation must conform with local codes or in the absence of local codes with the Standard for the Storage and Hand...
Страница 8: ...at to desired temperature To stop push the STOP button and turn gas off Fan will continue operating for 60 seconds Theapplianceareashouldbekeptclearandfreefromcombustiblematerials gasoline and other f...
Страница 9: ...ombustion quality End of season Manifold Pressure Check for nominal pressure specified in specification label Adjust regulator pressure if necessary Fan Blade Remove dirt buildup Replace damaged or un...
Страница 10: ...too high solenoid valve will not open Upstream regulators installed backwards Flame control failure Poor quality power such as from a generator Dirty signal or wrong hertz Motor running in reverse in...
Страница 11: ...ertz Other Problems Symptom Problem Motor relay failure Start switch failure Normal function Heater stops only if unplugged Stop switch failure Flame interrupts in function Frost on propane tank Propa...
Страница 12: ...O I L NO NO POWER RELAY 0 1 2 4 6 8 N O START N C STOP 2 1 X2 X1 3 4 1 NC 2 NO P COM AIR SWITCH Ground Screw C O I L NO NO BLOWER RELAY 0 1 2 4 6 8 BROWN 24VAC BLUE Call for Heat GREEN GROUND Thermos...
Страница 13: ...Output Burner Ground 24VAC R HV NC Alarm M Blower Motor Air Pressure Sw NO Burner Ground Igniter Gas Valve Solenoid 24VAC Inducer Power Supply Hi Limit Sw NC Thermostat Jumper Blower Relay 24VAC Coil...
Страница 14: ...Page 14 P N 974 9885 SE405 Manual Rev 1 2 33 34 SE405 HEATER PARTS DIAGRAM 1 2 4 5 7 6 9 10 11 12 13 14 15 16 17 18 19 20 22 27 23 24 25 26 28 29 30 31 41 42 43 44 45 47 49 50 51 52 53 54 46...
Страница 15: ...11 1525 Fan Blade 41 9872 Relay 12 9827 Motor 42 9879 Start Switch 13 6119 Semi Pneumatic W heel 43 9880 Stop Switch 14 SE 4721 Wheel Assembly 44 9881 Heat Fan Switch 15 SE 4726 Blower Plate Assembly...
Страница 16: ...ther it is impossible to completely empty a propane cylinder PRESSURE FLOW EQUIVALENTS 1 Std Atmosphere 14 73 lb sq in 1 014 bar 1 Water Column W C 0 58 oz sq in 2 49 millibar 11 Water Column 0 4 lb s...