3.3 DISTANCE FROM YOUR SWIMMING POOL
The heat pump is usually installed within a perimeter area
extending 7.5 m from the swimming pool. The greater the distance
from the pool, the greater the heat loss in the pipes. As the pipes
are mostly underground, the heat loss is low for distances up to
30m (15 m from and to the pump; 30 m in total) unless the ground
is wet or the groundwater level is high. A rough estimate of the
heat loss per 30 m is 0.6 kWh (2,000 BTU) for every 5 °C difference
between the water temperature in the pool and the temperature of
the soil surrounding the pipe. This increases the operating time by
3% to 5%.
1
Side Discharge
1
Top Discharge
Содержание heatseeker nova
Страница 1: ......