12

Installation

Using the Output Module with the enclosure

The Output Module can be installed inside the enclosure (ENCR-10) for physical and electrical protection. The enclosure 

includes a power status LED board, power distribution board, power supply, and tamper. The enclosure is sold 

separately.

Securing the battery

Insert the battery velcro strap into the enclosure and secure the battery.

 

• 

Use a backup battery with 12 VDC and 7 Ah or higher. This product was tested with 'ES7-12' battery of 
'ROCKET'. It is recommended to use a battery corresponding to 'ES7-12'.

• 

The battery is sold separately.

• 

If the dimension of the backup battery is larger than the recommended specification, it may not be able to be 
mounted in the enclosure or the enclosure may not close after it is mounted. Also, if the shape and dimension 
of the terminals are different, the battery cannot be connected using the cable provided.

151

65

43

94

99

4.75

6.6

0.8

6.35

Backup Battery

Terminal

(Unit: mm)

Содержание OM-120

Страница 1: ...Output Module INSTALLATION GUIDE Version 1 01 English EN 101 00 OM 120 V1 01A ...

Страница 2: ...of each part 6 LED Indicator 7 Installation example 7 Installation 8 Power Connection 8 RS 485 Connection 9 Relay Connection 10 AUX 11 Using the Output Module with the enclosure 12 Product Specifications 16 Dimensions 17 FCC compliance information 18 Appendices 19 Disclaimers 19 Copyright Notice 19 ...

Страница 3: ...ions or failure to follow installation instructions can void the manufacturer s warranty Do not install the product in a place with direct sunlight moisture dust soot or a gas leak This may result in electric shock or fire Do not install the product in a location with heat from an electric heater This may result in fire due to overheating Install the product in a dry location Humidity and liquids ...

Страница 4: ...duct The product may malfunction Do not press buttons on the product by force or do not press them with a sharp tool The product may malfunction When cleaning the product mind the following Wipe the product with a clean and dry towel If you need to sanitize the product moisten the cloth or the wipe with a proper amount of rubbing alcohol and gently clean all exposed surfaces including the fingerpr...

Страница 5: ...NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO RELAY 11 RELAY 10 RELAY 9 RELAY 8 RELAY 7 RELAY 6 POWER STATUS RESET INIT 12V 0V TRX TRX GND POWER GND AUX IN 1 GND AUX IN 0 AUX RS 485 ON OFF TERM 0 1 2 3 4 5 11 10 9 8 7 6 OM 120 Output Module OM 120 Drilling Template Fixing screw x12 Spacer x6 Components may vary according to the installation environment ...

Страница 6: ...r to Using the Output Module with the enclosure There is no optimal height for installing ENCR 10 on the wall Install it to a safe and convenient location for you to use Fixing screws for the enclosure the device and the power supply cable are included in the ENCR 10 package Use each screw correctly by following the details below Fixing screws for the enclosure diameter 4 mm length 25 mm x 4 Fixin...

Страница 7: ...OM NO RELAY 11 RELAY 10 RELAY 9 RELAY 8 RELAY 7 RELAY 6 POWER STATUS RESET INIT 12V 0V TRX TRX GND POWER GND AUX IN 1 GND AUX IN 0 AUX RS 485 ON OFF TERM 0 1 2 3 4 5 11 10 9 8 7 6 OM 120 RESET button INIT button Communication status LED RS 485 AUX Power status LED Operation status LED Relay 0 Relay 11 Relay 9 Relay 7 AUX1 Relay 10 Relay status LED 0 1 11 10 Relay status LED 2 3 9 8 Relay status LE...

Страница 8: ...d as daisy chain via RS 485 you can control up to 192 floors per elevator B3 B2 B1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC RELAY 0 RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5 NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO RELAY 11 RELAY 10 RELAY 9 RELAY 8 RELAY 7 RELAY 6 POWER STATUS RESET INIT 12V 0V TRX TRX GND POWER GND AUX IN 1 G...

Страница 9: ...RELAY 0 RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5 NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO RELAY 11 RELAY 10 RELAY 9 RELAY 8 RELAY 7 RELAY 6 POWER STATUS RESET INIT 12V 0V TRX TRX GND POWER GND AUX IN 1 GND AUX IN 0 AUX RS 485 ON OFF TERM 0 1 2 3 4 5 11 10 9 8 7 6 OM 120 Power Connection NO COM NC NO COM NC RELAY 4 RELAY 5 12V 0V TRX TRX GND POWER RS 485 ON OFF TERM DC Power Make ...

Страница 10: ...the chain the performance in communicating will deteriorate because it reduces the signal level Up to 31 modules can be connected to the master device NO COM NC NO COM NC RELAY 4 RELAY 5 NC COM NO NC COM NO RELAY 7 RELAY 6 12V 0V TRX TRX GND POWER GND AUX IN 1 GND AUX IN 0 AUX RS 485 ON OFF TERM 4 5 7 6 NO COM NC NO COM NC RELAY 4 RELAY 5 12V 0V TRX TRX GND POWER RS 485 ON OFF TERM Access Controll...

Страница 11: ...levator installer for details Each relay has to be connected to the corresponding floor Use the figure below as an example B3 B2 B1 1 NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC RELAY 0 RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5 12V POWER Elevator Control Panel B3 B2 B1 1 Elevator Floor Button ...

Страница 12: ...11 Installation AUX The dry contact output or tamper can be connected NC COM NO NC COM NO RELAY 7 RELAY 6 GND AUX IN 1 GND AUX IN 0 AUX Tamper ...

Страница 13: ...he battery Use a backup battery with 12 VDC and 7 Ah or higher This product was tested with ES7 12 battery of ROCKET It is recommended to use a battery corresponding to ES7 12 The battery is sold separately If the dimension of the backup battery is larger than the recommended specification it may not be able to be mounted in the enclosure or the enclosure may not close after it is mounted Also if ...

Страница 14: ... IN 0 AUX RS 485 ON OFF TERM 0 1 2 3 4 5 11 10 9 8 7 6 OM 120 NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC RELAY 0 RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5 NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO RELAY 11 RELAY 10 RELAY 9 RELAY 8 RELAY 7 RELAY 6 POWER STATUS RESET INIT 12V 0V TRX TRX GND POWER GND AUX IN 1 GND AUX IN 0 AUX RS 485 ON OFF TERM 0 1 2 3 4 5 11 10 9 8 ...

Страница 15: ...ed to the AUX IN terminal 12V 0V TRX TRX GND POWER GND AUX IN 1 GND AUX IN 0 AUX RS 485 ON OFF TERM Make sure to use separate power for the access control device and Output Module Use the correct power specifications 12 VDC 1 A Use a backup battery with 12 VDC and 7 Ah or higher This product was tested with ES7 12 battery of ROCKET It is recommended to use a battery corresponding to ES7 12 ...

Страница 16: ...AY 2 RELAY 3 RELAY 4 RELAY 5 NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO RELAY 11 RELAY 10 RELAY 9 RELAY 8 RELAY 7 RELAY 6 POWER STATUS RESET INIT 12V 0V TRX TRX GND POWER GND AUX IN 1 GND AUX IN 0 AUX RS 485 ON OFF TERM 0 1 2 3 4 5 11 10 9 8 7 6 OM 120 NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC 12V 0V TRX TRX GND ON OFF NO COM NC NO COM NC NO COM NC NO COM NC NO C...

Страница 17: ...emperature 20 C 60 C Storage Temperature 40 C 70 C Operating Humidity 0 95 non condensing Storage Humidity 0 95 non condensing Dimension W x H x D 90 mm x 190 mm x 21 mm Weight 300 g Certificates CE FCC KC RoHS REACH WEEE Interface RS 485 1 ch AUX Input 2ch Dry Contact Input Relay 12 relays Capacity Text Log 10ea per port Electrical Power Voltage 12VDC Current Max 1 A Switch Input VIH Max 5 V Dry ...

Страница 18: ... COM NC NO COM NC RELAY 0 RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5 NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO RELAY 11 RELAY 10 RELAY 9 RELAY 8 RELAY 7 RELAY 6 POWER STATUS RESET INIT 12V 0V TRX TRX GND POWER GND AUX IN 1 GND AUX IN 0 AUX RS 485 ON OFF TERM 0 1 2 3 4 5 11 10 9 8 7 6 OM 120 190 90 ...

Страница 19: ...ese limits are designed to provide reasonable protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interfer...

Страница 20: ...claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim of personal injury or death associated with such unintended or unauthorized use even if such claim alleges that Suprema was negligent regarding the design or manufacture of the part Suprema reserves the right to make changes to specifications and product descriptions at any time without n...

Страница 21: ...names and numbers herein are registered trade marks of Suprema Inc All non Suprema brands and product names are trademarks or registered trademarks of their respective companies Product appearance build status and or specifications are subject to change without notice For more information about Suprema s global branch offices visit the webpage below by scanning the QR code http www supremainc com ...

Отзывы: