Input Module
INSTALLATION GUIDE
Version 1.00
English
EN 101.00.IM-120 V1.00A
Страница 1: ...Input Module INSTALLATION GUIDE Version 1 00 English EN 101 00 IM 120 V1 00A ...
Страница 2: ... Installation 8 Power Connection 8 RS 485 Connection 9 Relay Connection 10 Supervised Input Connection 11 Tamper Connection 12 Using the Input Module with the enclosure 12 Product Specifications 17 FCC compliance information 19 Appendices 20 Disclaimers 20 Copyright Notice 20 Open Source License 20 MIT Open Source License 21 ...
Страница 3: ...ions or failure to follow installation instructions can void the manufacturer s warranty Do not install the product in a place with direct sunlight moisture dust soot or a gas leak This may result in electric shock or fire Do not install the product in a location with heat from an electric heater This may result in fire due to overheating Install the product in a dry location Humidity and liquids ...
Страница 4: ...roduct may malfunction Do not press buttons on the product by force or do not press them with a sharp tool The product may malfunction Do not store your product in very hot or very cold places It is recommended to use the product at temperatures from 20 C to 60 C The product may malfunction When cleaning the product mind the following Wipe the product with a clean and dry towel If you need to sani...
Страница 5: ... IM 120 Input Module IM 120 Drilling Template Input Module 201 00 IM 120 V1 00A Open Source Software MIT License 306 01 V1 02A E Fixing screw x12 Spacer x6 Quick Guide Open Source Software Guide Components may vary according to the installation environment ...
Страница 6: ... to Using the Input Module with the enclosure There is no optimal height for installing ENCR 10 on the wall Install it to a safe and convenient location for you to use Fixing screws for the enclosure the device and the power supply cable are included in the ENCR 10 package Use each screw correctly by following the details below Fixing screws for the enclosure diameter 4 mm length 25 mm x 4 Fixing ...
Страница 7: ...0 1 and Tamper connection 7 RS 485 terminating resistance switch 8 RS 485 connection 9 Power connection DC 12 24 V 10 Relay 0 connection 11 Supervised Input 3 4 5 connection 12 Supervised Input 0 1 2 connection Press and hold the INIT button for 2 seconds or longer to initialize the Input Module currently linked with a device and connect it to a different device 1 2 3 4 5 6 7 8 10 9 11 12 ...
Страница 8: ...d Relay operation RS 485 TX Blinking orange Transmitting RS 485 data RS 485 RX Blinking green Receiving RS 485 data AUX IN 0 1 Solid orange Receiving an AUX signal TAMPER Solid orange Tamper operation Installation example The Input Module provides instant relay behavior by connecting to BioStar 2 for detected inputs in real time and it operates a relay or saves logs for detected inputs while it is...
Страница 9: ...ule using a fixing screw 2 Fix the product on top of the fixed spacer firmly using a fixing screw Power Connection DC Power Make sure to use separate power for the access control device and Input Module Use the correct power specifications 12 VDC 130 mA or 24 VDC 82 mA It is recommended to connect and use an Uninterruptible Power Supply UPS to prevent power failure 12 VDC or 24 VDC GND ...
Страница 10: ...onnection If connected to the middle line the signal level becomes smaller and the communication performance will deteriorate Make sure to connect it to both ends of the daisy chain connection Set the termination switch TERM to ON for Input Module RS485 wire size shall be over 26 AWG and all wiring must comply with National Electrical Code ANSI NFPA 70 Master Device Slave Device Terminating resist...
Страница 11: ...l Safe Lock When the relay is activated blocking the current flow the door will open If the power supply to the product is cut off due to a power failure or an external factor the door will open Fail Secure Lock In order to use the Fail Secure Lock connect NO relay as shown in the figure below There is normally no current flowing through the relay for the Fail Secure Lock When the current flow is ...
Страница 12: ...g through the circuit to monitor device disconnection short on and off conditions and can also be used as a general TTL input With BioStar 2 you can set the behavior according to the Supervised Input status and you can monitor the status of each input EMERGENCY Do not connect the input of the Input Module in duplicate to the device connected to the input port of the master device The Input Module ...
Страница 13: ... the enclosure ENCR 10 for physical and electrical protection The enclosure includes a power status LED board power distribution board power supply and tamper The enclosure is sold separately Securing the battery Insert the battery velcro strap into the enclosure and secure the battery Use a backup battery with 12 VDC and 7 Ah or higher This product was tested with ES7 12 battery of ROCKET It is r...
Страница 14: ...nclosure may not close after it is mounted Also if the shape and dimension of the terminals are different the battery cannot be connected using the cable provided 151 65 43 94 99 4 75 6 6 0 8 6 35 Backup Battery Terminal Unit mm Installing the Input Module in the enclosure 1 Check the position to install the Input Module in the enclosure You can install two Input Modules in one enclosure ...
Страница 15: ...convenient location for you to use Fixing screws for the enclosure the device and the power supply cable are included in the ENCR 10 package Use each screw correctly by following the details below Fixing screws for the enclosure diameter 4 mm length 25 mm x 4 Fixing screws for the device diameter 3 mm length 5 mm x 6 Fixing screws for the power supply cable diameter 3 mm length 8 mm x 1 ...
Страница 16: ...e Power Supply UPS to prevent power failure And a power failure detector or a dry contact output can be connected to the AUX IN terminal Make sure to use separate power for the access control device and Input Module Use the correct power specifications 12 VDC 130 mA or 24 VDC 82 mA ...
Страница 17: ...Connection If Input Module is detached from the installed location due to an external factor it can trigger an alarm or save an event log For more information contact the Suprema technical support team support supremainc com ...
Страница 18: ...x D 90 mm x 190 mm x 21 mm Weight 203 g Certificates CE FCC KC RoHS REACH WEEE Interface Supervised Input 12 ch TTL Input selectable RS 485 1 ch Relay 2 relays AUX Input 2 ch AC POWER FAIL Tamper Input 1 ch Capacity Text Log 10ea per port Electrical Power Power DC 12 V Max 130 mA or DC 24 V Max 82 mA Adapter recommended specifications DC 12 V 10 with a minimum of 1 A or DC 24 V 10 with a minimum o...
Страница 19: ...18 Product Specifications Dimensions Unit mm The tolerance is 0 3 mm 101 90 190 21 ...
Страница 20: ...ese limits are designed to provide reasonable protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interfer...
Страница 21: ...indirectly any claim of personal injury or death associated with such unintended or unauthorized use even if such claim alleges that Suprema was negligent regarding the design or manufacture of the part Suprema reserves the right to make changes to specifications and product descriptions at any time without notice to improve reliability function or design Personal information in the form of authen...
Страница 22: ...o so subject to the following conditions The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software THE SOFTWARE IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT IN NO EVENT SHALL THE AUTHORS OR COPYR...
Страница 23: ...names and numbers herein are registered trade marks of Suprema Inc All non Suprema brands and product names are trademarks or registered trademarks of their respective companies Product appearance build status and or specifications are subject to change without notice For more information about Suprema s global branch offices visit the webpage below by scanning the QR code http www supremainc com ...