background image

BEWI

Compact Outdoor Fingerprint Reader/Controller

Operation Description

www.supremainc.com

Содержание BEWI

Страница 1: ...BEWI Compact Outdoor Fingerprint Reader Controller Operation Description www supremainc com...

Страница 2: ...BioEntry W Components Basic Components Wall Mount Screws 2 Main Unit Mounting Screws 2 Copyright 2007 Suprema Inc 2 BioEntry W Wall Mounting bracket 1 Software CD 1...

Страница 3: ...BioEntry W Components Optional Accessories Copyright 2007 Suprema Inc 3 USB Fingerprint Scanner 12VDC Power Adaptor Plastic Stand Secure I O...

Страница 4: ...card over the scanner Color per 2sec Standard Operation Flicker Red Pink Color per 2sec Device Locked Flicker Blue Red Color per 2sec Discharged Internal Battery Flicker Blue Yellow Color per 2sec Una...

Страница 5: ...bles Power Cables RS485 Cables Ethernet Connector Input Cables Relay Cables Copyright 2007 Suprema Inc 5 Relay Cables LED Network Status LED Network Reset Switch See Resetting Network Settings page 28...

Страница 6: ...BioEntry W Dimensions 50 mm 40 mm 44 mm BioEntry W Wall Mounting Bracket Copyright 2007 Suprema Inc 6 172 mm 157 mm 172 mm...

Страница 7: ...RXN YELLOW 7 POWER IN RED 8 POWER GND BLACK 9 PoE VB2 BLUE Copyright 2007 Suprema Inc 7 9 PoE VB2 BROWN 10 PoE VB1 RED PoE VB1 GREEN 11 485 TRXN YELLOW WHITE STRIPE 12 485 TRXP BLUE WHITE STRIPE 13 48...

Страница 8: ...ting bracket on a wall by using wall mounting screws 2 Hook the device on the wall mount bracket 3 Fix the device to the wall mounting bracket using the star shaped screws Star shaped screw Copyright...

Страница 9: ...BioEntry W System Configurations Door Lock Door Sensor Exit Button Standard Copyright 2007 Suprema Inc 9 Door Lock Exit Button PC LAN BioEntry W USB Fingerprint Scanner...

Страница 10: ...BioEntry W System Configurations RS485 Door Sensor Secure Secure I O Copyright 2007 Suprema Inc 10 Exit Button PC LAN BioEntry W Secure I O Door Lock USB Fingerprint Scanner...

Страница 11: ...Secure I O RS485 RS485 System Configurations FaceStation Copyright 2007 Suprema Inc 11 Door Zone 2 Anti passback BioEntry W BioEntry W LAN Secure I O BioEntry W Exit Button PC Server PC Client PC Clie...

Страница 12: ...Recommended Power Specifications 12V 10 at least 500mA Comply with standard IEC EN 60950 1 When sharing power with other devices use a power supply with a higher current rating UPS Optional DC Power S...

Страница 13: ...cted with a regular hub or PoE hub by connecting the Ethernet cable to the Ethernet terminal PoE Power over Ethernet is an Ethernet connection of which the power is supplied from PSE Power Sourcing Eq...

Страница 14: ...Ethernet Connection Direct connection with PC Use a standard CAT 5 cable to connect the device directly to a PC BioEntry W supports auto MDI MDIX therefore a crossover cable is not necessary Copyrigh...

Страница 15: ...both ends of the bus should be terminated To enable termination on the RS232 485 converter refer to the converter s manual Adjust the communication speed as needed The signal quality vary depending on...

Страница 16: ...r IN Red Power GND Black Signal GND Black White Stripe TRX Blue White Stripe TRX Yellow White Stripe BioEntry W Copyright 2007 Suprema Inc 16 Notes For bus termination only the devices at both ends of...

Страница 17: ...nnections Relay Connection Fail safe lock BioEntry W 20 Relay NO Gray White Stripe 19 Relay COM Green White Stripe 18 Relay NC Orange White Stripe Copyright 2007 Suprema Inc 17 Deadbolt Door strike DC...

Страница 18: ...nections Relay Connection Fail secure lock BioEntry W 20 Relay NO Gray White Stripe 19 Relay COM Green White Stripe 18 Relay NC Orange White Stripe Copyright 2007 Suprema Inc 18 Deadbolt Door strike D...

Страница 19: ...Relay Connection Automatic door RTE Switch Presence Detector Copyright 2007 Suprema Inc 19 RTE Switch Automatic Door BioEntry W 20 Relay NO Gray White Stripe 19 Relay COM Green White Stripe 18 Relay...

Страница 20: ...al Input Connection RTE Door sensor BioEntry W 13 485 GND Black White Stripe Copyright 2007 Suprema Inc 20 13 485 GND Black White Stripe 1 Input 1 Brown 13 485 GND Black White Stripe 2 Input 0 Purple...

Страница 21: ...ital Input Connection Alarm Emergency switch BioEntry W 13 485 GND Black White Stripe Copyright 2007 Suprema Inc 21 13 485 GND Black White Stripe 1 Input 1 Brown 13 485 GND Black White Stripe 2 Input...

Страница 22: ...White Black Stripe 15 Wiegand D1 White 16 Wiegand D0 Green RFID Reader GND Wiegand D1 Wiegand D0 Copyright 2007 Suprema Inc 22 Wiegand Output Controller GND Wiegand D1 Wiegand D0 BioEntry W 14 Wiegand...

Страница 23: ...itch on the back panel of the device Please refer to the figures as below 1 Turn on the device 2 Press and hold the network reset switch until the device turns off Then the device will restart Network...

Страница 24: ...Pull up resistance 4 7k The input ports are pulled up with 4 7k resistors Copyright 2007 Suprema Inc 24 TTL Wiegand Output VOH V 5 VOL V 0 8 Pull up resistance 4 7k The outputs ports are open drain ty...

Страница 25: ...BioEntry W Operation Diagram Copyright 2007 Suprema Inc 25...

Страница 26: ...16 Tel 031 783 4510 Tel 031 783 4510 Fax 031 783 4503 sales suprema co kr www suprema co kr www biostation co kr BioEntry Plus...

Отзывы: