- 10 -
1.4 WATER SUPPLYING SYSTEM
1.4.1
D
ESCRIPTION
1.4.1.1 General status:
> Edger must install valve to control water supply, position of valve cannot be 80cm higher than
edger. Valve must be operated easily so when stop machine, people can close water supply
anytime.
> Drain piper diameter is 100 mm. To make sure discharging all scrap, we should have at least a
5% slope.
1.4.1.2 Filter tank with water pump
> Length=500mm width=400mm height=280 mm
> Volume: 50L
1.4.1.3 Water pump
> Power = 40 W
> Flow rate = 12L/Minute
> Discharge height = 3.0m
> Voltage = 220V-230V/50Hz 110V-115V/60Hz
1.4.1.4 Magnetic valve
> Voltage = 220V-230V /50Hz 110V-115V /60Hz
> Power = 20 W
1.4.2
P
IPER CONNECTIOIN
> Piper connection as below figure:
Drain water piper
Edging front water
Edging back water