SUPMEA Y290 Скачать руководство пользователя страница 1

User's Manual 

Digital pressure gauge

U-

P3.1

-

MY

EN

6

Supmea Automation Co.,Ltd

.

www.supmea.com

Headquarters

5th floor,Building 4,Singapore Hangzhou Science Technology Park,
No. 6 street,Hangzhou Economic Development Area,
Hangzhou 310018,China

info@supmea.com

Singapore / Philippines

Содержание Y290

Страница 1: ...U P3 1 MYEN6 Supmea Automation Co Ltd www supmea com Headquarters 5th floor Building 4 Singapore Hangzhou Science Technology Park No 6 street Hangzhou Economic Development Area Hangzhou 310018 China i...

Страница 2: ...ses caused by false operation Note Modification of this manual s contents will not be notified as a result of some factors such as function upgrading We try our best to guarantee that the manual conte...

Страница 3: ...is damaged Package contents S N Item Name Qty 1 Digital pressure gauge 1 2 Manual 1 3 Certificate 1 Note When the backlight is not required please turn off the backlight to extend the battery life If...

Страница 4: ...oduction 1 1 1 Features 2 Chapter 2 Parameters 3 Chapter 3 Display Button 4 Chapter 4 Calibration 6 Chapter 5 The peak save function 6 Chapter 6 Dimension installation 7 Chapter 7 Note 8 Chapter 8 War...

Страница 5: ......

Страница 6: ...quipped with large size LCD liquid crystal display with clear backlight switch machine unit switching low voltage alarm and other functions it s easy to operate and install The products using 304 stai...

Страница 7: ...th temperature compensation small temperature coefficient and accurate measurement Maximum 1 1 times of range overload display and it has a peak record function Four digit half segment display accurat...

Страница 8: ...0 5 Long term stability 0 2 FS Y Dimension 81mm H131mm W47mm Weight 440g Power supply 3V 2 AAA batteries Battery Life 6months According to the specific condition of use Sampling frequency 3times seco...

Страница 9: ...y Button www supmea com 4 Chapter 3 Display Button On off Press to switch unit Press and hold for 3 seconds to calibrate the zero point error Press to turn on off the backlight hold the press to keep...

Страница 10: ...Chapter 3 Display Button www supmea com 5 Symbol Meaning kPa psi kgf cm2 bar MPa Pressure unit MAX Maximum pressure MIN Minimum pressure Battery power...

Страница 11: ...l support to avoid damage to the product Chapter 5 The peak record function Press and hold the Unit button for 3 seconds to display the maximum value of MAX recorded after the last clear Press the Uni...

Страница 12: ...stallation or horizontal installation 2 The pressure can not exceed the range while using 3 When there is no pressure but the pressure value is displayed please press the Zero key to calibrate zero er...

Страница 13: ...evice the user may not disassemble the product not with a hard object touch the film so as to avoid damage to the product In the installation process please use of hex wrench not strong installation o...

Страница 14: ...ance content If the product general parts and components don t work we are responsible for free repair If the product main parts components don t work it can not be repaired and non artificial causes...