background image

SC747 Chassis Manual

6-6

Figure 6-2:  Identifying the Inner Rails and Chassis Handles

Chassis Handle

Inner Rails

Identifying the Sections of the Rack Rails

The  chassis  package  includes  two  rack  rail  assemblies  in  the  rack  mounting  kit.  

Each  assembly  consists  of  two  sections:  an  inner  fixed  chassis  rail  that  secures 
directly to the server chassis and an outer fixed rack rail that secures directly to 

the rack itself.

Содержание SC747TQ-R1400B

Страница 1: ...SC747TQ R1400B USER S MANUAL 1 0 SC747 CHASSIS Series SUPER...

Страница 2: ...D OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall b...

Страница 3: ...connectors to support up to four double width GPU cards Optimized redundant high efficiency 93 Gold Level 1400W power supplies with PMBus support and optimized thermal solutions with four hot swap co...

Страница 4: ...s on this chassis model including the fans bays airflow shields and other components Chapter 4 System Interface Refer to this chapter for details on the system interface which includes the functions a...

Страница 5: ...supply specifications and compatible backplanes Not all compatible backplanes are listed Refer to our Web site for the latest compatible backplane information Appendix A Chassis Cables Appendix B Pow...

Страница 6: ...stem Safety 2 1 2 1 Overview 2 1 2 2 Warnings and Precautions 2 1 2 3 Preparing for Setup 2 1 2 4 Electrical Safety Precautions 2 2 2 5 General Safety Precautions 2 3 2 6 System Safety 2 3 Chapter 3 C...

Страница 7: ...ptional Standoffs 5 17 Installing the Motherboard 5 18 Installing the Active Heatsink 5 19 Power Supply Connections 5 20 Configuring the Add on Card Expansion Slot 5 21 Installing Double Width Graphic...

Страница 8: ...SC747 Chassis Manual viii Notes...

Страница 9: ...for FB DIMM memory modules and 8 hot swap drive bays offer maximum storage capacity in a 4U form factor 1 2 Shipping List Please visit the following link for the latest shipping lists and part number...

Страница 10: ...These drives are hot swappable Once set up correctly these drives can be removed without powering down the server I O Expansion slots Each version of the SC747 Chassis includes eleven full I O expansi...

Страница 11: ...dress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl T...

Страница 12: ...SC747 Chassis Manual 1 4 Notes...

Страница 13: ...hows damage file a damage claim with carrier who delivered your system Decide on a suitable location for the rack unit that will hold that chassis It should be situated in a clean dust free area that...

Страница 14: ...m When working around exposed electrical circuits another person who is fa miliar with the power off controls should be nearby to switch off the power if necessary Use only one hand when working with...

Страница 15: ...ou if they come into contact with printed circuit boards or areas where power is present After accessing the inside of the system close the system back up and secure it to the rack unit with the reten...

Страница 16: ...wrist strap Handle a board by its edges only do not touch its components peripheral chips memory modules or contacts When handling chips or modules avoid touching their pins Put the serverboard and p...

Страница 17: ...d on card For the latest shipping lists visit our Web site at http www supermicro com This chassis accepts four hot swappable system cooling fans and two power sup plies SC747 models come in dark gray...

Страница 18: ...likely event your power supply fails replacement is simple and can be done without tools 3 3 Where to get Replacement Components Though not frequently you may need replacement parts for your system To...

Страница 19: ...to keep you constantly informed of the overall status of the system as well as the activity and health of specific components Most SC747 models are two buttons on the chassis a control panel a reset b...

Страница 20: ...he system Therefore you must unplug system before servicing Reset The reset button is used to reboot the system 4 3 Control Panel LEDs The control panel located on the front of the SC747 chassis has f...

Страница 21: ...bstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to m...

Страница 22: ...as a green LED When illuminated this green LED on the front of the SATA drive carrier indicates drive activity A con nection to the SATA backplane enables this LED to blink on and off when that partic...

Страница 23: ...ing Chassis Cover Opening the Front Cover Configuring the Storage Module Installing Hard Drives Installing the Motherboard Installing the Heatsink General Maintenance General Maintenance Systems Fans...

Страница 24: ...op cover and the front cover This section of the manual is describes removing the main cover and opening the front cover Removing the top cover is described in Chapter 6 in the section titled Installi...

Страница 25: ...Removing the Chassis Main Cover Lift up and back on the main cover handle which secures the cover to the 1 chassis Lift the main cover off of the chassis 2 Figure 5 2 Removing the Main Cover 1 1 1 2 1...

Страница 26: ...appable hard drives The cover can be locked to prevent unauthorized access The key to this lock is shipped with the system Opening the Front Cover 1 Unlock the front cover using the key shipped with t...

Страница 27: ...used as desktop server If the chassis is to be used in a rack the storage module must be rotated 90 degrees and the storage moudule cover must be replaced This can be done before during or after setu...

Страница 28: ...omponent in the chassis Push the storage module release lever This lever unlocks the storage mod 3 ule Grasp the external edges of the storage module and pull the unit from the 4 chassis Turn the stor...

Страница 29: ...configured in one of three ways Add up to three extra hard drives to the drive trays 1 Add up to three peripheral drives CD ROM DVD ROM etc drive trays 2 Add five hot swappable hard drives to the stor...

Страница 30: ...bs Adding Hard Drives to the Drive Carriers Open the chassis cover 1 Locate the drive tray release tab for the slot you want to place the peripheral 2 drive Push the drive tray toward the front of the...

Страница 31: ...on your motherboard The hard drive may not completely fill the tray Secure the hard drive to the carrier with four screws from the bottom 5 Slide the hard drive into the chassis until the carrier clic...

Страница 32: ...ives DVD ROM CD ROM floppy drive etc to the drive trays Adding Peripheral Drives Open the chassis cover 1 Locate the drive tray release tab for the slot you want to place the peripheral 2 drive Push t...

Страница 33: ...om each side 5 Attach the rails to a DVD ROM CD ROM floppy drive or other peripheral The rails should fit any standard sized peripherals 6 Slide the peripheral into the chassis until the tray clicks i...

Страница 34: ...le rack to install extra hot swappable hard drives The mobile rack goes into the storage module which goes into the chassis For more information on mobile rack installation and use refer to the append...

Страница 35: ...for all three hard drive trays Hard Drive Rails Hard Drive Tray Figure 5 13 Removing the Hard Drive Rails Figure 5 14 Adding Hard Drive Rails to a Storage Rack Attach the rails to a DVD ROM CD ROM fl...

Страница 36: ...also help promote proper airflow for the drive bays Installing Hard Drives 1 Unlock and open the chassis cover 2 Press the release button to extend the drive tray handle 3 Using the handle pull the dr...

Страница 37: ...into the chassis To do this 7a Press the hard drive release button to extend the drive tray handle 7b Insert the hard drive into the chassis and close the handle to lock the hard drive into place Figu...

Страница 38: ...I O Shield Installing the I O shield Review the documentation that came with your motherboard Become familiar 1 with component placement requirements and precautions Open the chassis cover 2 Choose t...

Страница 39: ...hort circuits by securing space between the motherboard and the chassis surface The SC747 chassis packaging includes optional standoffs hexagon shaped posts These standoffs accept the rounded Phillips...

Страница 40: ...ave a permanent standoff To do this A Place a hexagonal standoff screw through the bottom the chassis B Secure the screw with the hexagon nut rounded side up Do not exceed more than eight pounds of to...

Страница 41: ...1 Installing the Active Heatsink Installation of the active heatsink will vary depending upon the type of motherboard used in the chassis See the information which was supplied with the motherboard fo...

Страница 42: ...wer cable 2 backplane Each cable has three connectors two Hard Drive HDD and one Floppy Drive FDD Attach the HDD connectors to the backplane If you are using a Supermicro backplane the FDD con nector...

Страница 43: ...o the chassis such as PCI cards Installing Add on Expansion Cards Locate the release tab on the top of the PCI slot bracket 1 Gently apply pressure in the middle of the release tab to unlock the PCI s...

Страница 44: ...rboard To do this slide the PCI card with L bracket into the PCI slot and secure the card to the motherboard Push the PCI bracket release tab down until it locks into place with an audible 6 click Sec...

Страница 45: ...rt number bracket is recommended for this application and may be purchased by visiting the Supermicro Web site at http www supermicro com and clicking on the Where to Buy link Installing Double Width...

Страница 46: ...card bracket into the slots on the 3 wall of the chassis as illustrated Lower the bracket down onto the card 4 Pull back the slide lock and lower it over the raised tab as illustrated 5 Push the slid...

Страница 47: ...5 7 System Fans Replacing Mid System Fans Replacing Mid System Fans 1 Determine which fan has failed Because the fans are hot swappable the chassis does not need to be powered down 2 Press the fan re...

Страница 48: ...lacing the Rear System Fan Determine which fan is not operation 1 Press the rear fan release tab 2 Pull the fan away from the chassis by pulling out the top first 3 Place the new fan in the chassis in...

Страница 49: ...pply With a redundant power supply the system automatically switches to the second power supply if the first should fail Replacing the Power Supply Power down the chassis and unplug the power cord If...

Страница 50: ...SC747 Chassis Manual 5 28 Notes...

Страница 51: ...noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Be sure to read the Rack and Server Precautions in the next section 6 3 Preparing for Setup Th...

Страница 52: ...General Server Precautions Review the electrical and general safety precautions that came with the com ponents you are adding to your chassis Determine the placement of each component in the rack befo...

Страница 53: ...re Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack...

Страница 54: ...ure will differ slightly You should also refer to the installation instructions that came with the rack unit you are using NOTE The outer rail is adjustable from 26 to 38 25 Removing the Chassis Cover...

Страница 55: ...cover off the chassis 3 Removing the Chassis Feet Place the chassis on its side with the chassis side cover facing upward 1 Remove the screw holding the chassis foot in place 2 The foot lock is a tab...

Страница 56: ...ils Identifying the Sections of the Rack Rails The chassis package includes two rack rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that se...

Страница 57: ...assis handle with the front of the chassis and secure with the 2 three chassis handle screws Repeats steps 1 and 2 with the other handle 3 Locate the inner rails and screws in the shipping package 4 A...

Страница 58: ...the proper distance so that the rail fits snugly into the rack 3 Secure the rear of the outer rail with two M5 screws and the rear of the rack NOTE The outer rail is adjustable from approximately 26...

Страница 59: ...ner rails and the outer rails 2 Align the inner chassis rails with the front of the outer rack rails C 3 Slide the inner rails into the outer rails keeping the pressure even on both sides you may have...

Страница 60: ...return the chassis to tower mounting Installing the Chassis Cover Installing the Cover Remove the rack mount ears 1 Align the cover post with the corresponding holes on the top of the chassis 2 and pl...

Страница 61: ...e foot receptacle and slide the foot toward the 1 front of the chassis The foot should lock into place Secure the foot to the chassis using one screw enclosed in the packaging 2 Repeat steps 1 and 2 f...

Страница 62: ...SC747 Chassis Manual 6 12 Notes...

Страница 63: ...the motherboard you are using and our Web site at www supermicro com A 2 Cables Included with SC747TQ Chassis SAS SATA SC747TQ R1400 Part Type Length Description CBL 0157L Cable 40cm 8 pin to 8 pin ri...

Страница 64: ...0175L Alt Name Big Four Alternate SAS SATA Cables Some compatible motherboards have different connectors If your motherboard has only one SAS connector that the SAS SATA cables must share use one of t...

Страница 65: ...pin CBL 0059 7 9 20 CM 8 pin CBL 0062 7 9 20 CM 4 pin CBL 0060 7 9 20 CM Front Panel to the Motherboard The SC747 chassis includes a cable to connect the chassis front panel to the motherboard If you...

Страница 66: ...SC747 Chassis Manual A 4 Notes...

Страница 67: ...lists power supply specifications for your chassis system 1400W Redundant MFR Part PWS 1K41P 1R AC Input 1200W 100 140V 50 60Hz 10 5 14 7 Amp 1400W 180 240V 50 60Hz 7 2 9 5 Amp DC Output 5V standby 4...

Страница 68: ...SC747 Chassis Manual B 2 Notes...

Страница 69: ...vent static discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not touch its components peripheral chips memory modul...

Страница 70: ...hown in this manual C 4 Introduction to the SAS 747TQ Backplane The SAS 747TQ backplane has been designed to utilize the most up to date tech nology available providing your system with reliable high...

Страница 71: ...ECT JP61 FAN 1 SELECT FAN 3 1 0 3 2 5 4 6 7 5V GND GND 12V 5V GND 12V GND ACT4 ACT3 ACT2 ACT1 ACT7 ACT6 ACT5 ACT0 C C C 2 3 55 1 2 50 OPEN 45 JP25 OH TEMP JP97 FAN 1 SELECT JP98 FAN 2 SELECT JP99 FAN...

Страница 72: ...n 1 Upgrade Connector The upgrade connector designated JP69 is used for manufacturer s diagnostic purposes only 3 Sideband Headers The sideband headers are designated JP66 and JP68 For SES 2 to work p...

Страница 73: ...Pin Definition 1 Ground 2 12V 3 Tachometer 4 Empty SAS Activity LED Header Pin Definitions Pin Definition Pin Definition 1 ACT IN 0 6 ACT IN 4 2 ACT IN 1 7 ACT IN 5 3 ACT IN 2 8 ACT IN 6 4 ACT IN 3 9...

Страница 74: ...1 FAN 1 SELECT FAN 3 1 0 3 2 5 4 6 7 5V GND GND 12V 5V GND 12V GND ACT4 ACT3 ACT2 ACT1 ACT7 ACT6 ACT5 ACT0 C C C 2 3 55 1 2 50 OPEN 45 JP25 OH TEMP JP97 FAN 1 SELECT JP98 FAN 2 SELECT JP99 FAN 3 SELEC...

Страница 75: ...d 2 3 Disabled FAN 2 enable disable JP98 1 2 Enabled 2 3 Disabled FAN 2 selection for MG9072 chip JP63 1 2 Enabled 2 3 Disabled FAN 3 enable disable JP99 1 2 Enabled 2 3 Disabled FAN 3 selection for M...

Страница 76: ...lt mode and can be used without making changes to your jumpers The following information details which jumpers must be configured to use I2 C mode or restore your backplane to SGPIO mode SGPIO and I2...

Страница 77: ...I2C 2 I2C 1 SIDEBAND 1 7 J7 7 J6 7 J5 JP60 R99 C A D47 C A D45 C A D51 U18 U42 RP1 RP3 JP69 1 2 5 6 D58 1 JP62 3 1 JP84 3 1 JP97 Y1 C99 C107 C89 C3 C44 1 17 32 33 48 49 64 U19 JP26 GND FAN 2FAIL FAN...

Страница 78: ...S747TQ REV 1 00 F10 F5 F6 J9 J4 J3 J2 J1 J15 J13 J11 R96 R95 R90 R88 R85 R84 R83 R89 R87 R86 R178 R165 R164 R150 R149 R173 C A D8 C A D7 C A D6 C A D5 C A D29 C A D23 C A D20 C A D19 C A D24 C A D22 C...

Страница 79: ...C 11 SAS 747TQ Backplane Specitications Notes...

Страница 80: ...reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products fo...

Отзывы: