background image

 H8QM3-2 

  

 

 

 

H8QMi-2

 

 

 

 

 

 

 

 

 

 
 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER’S MANUAL

Revision 1.0c

   

S

UPER

®

Содержание H8QM3-2

Страница 1: ...H8QM3 2 H8QMi 2 USER S MANUAL Revision 1 0c SUPER...

Страница 2: ...UPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTW...

Страница 3: ...ed information about the chipset Chapter 2 begins with instructions on handling static sensitive devices Read this chapter when installing the processor s and memory modules and when installing the se...

Страница 4: ...Power Supply 1 12 1 6 Super I O 1 12 Chapter 2 Installation 2 1 Static Sensitive Devices 2 1 2 2 Processor and Heatsink Installation 2 2 2 3 Mounting the Serverboard into a Chassis 2 4 2 4 Installing...

Страница 5: ...JLAN Enable Disable 2 14 I2 C to PCI X Slots 2 14 I2 C to PCI E Slots 2 14 Compact Flash Master Slave 2 14 Watch Dog Enable Disable 2 15 PCI X Slot Speed 2 15 SAS RAID Select 2 16 2 8 Onboard Indicato...

Страница 6: ...dures 3 2 3 3 Frequently Asked Questions 3 3 3 4 Returning Merchandise for Service 3 4 Chapter 4 BIOS 4 1 Introduction 4 1 4 2 Main Menu 4 2 4 3 Advanced Settings Menu 4 2 4 4 Boot Menu 4 16 4 5 Secur...

Страница 7: ...n quality and performance Please check that the following items have all been included with your serverboard If anything listed here is damaged or missing contact your retailer Included with retail bo...

Страница 8: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...

Страница 9: ...Chapter 1 Introduction 1 3 Figure 1 1 H8QM3 2 Image Note the H8QMi 2 has the same layout but does not include SAS ports or compo nents...

Страница 10: ...1B DIMMB 1A DIMMB 2B DIMMB 2A DIMMB 3B DIMMB 3A DIMMB 4B DIMMB 4A Kybd Mouse JLAN1 USB0 1 COM1 VGA JLAN2 ATI ES 1000 SIMLC Slot 1 PCI X 133 100 MHz Slot 2 PCI Express x16 Slot 3 PCI Express x8 Slot 4...

Страница 11: ...used with SAS COM1 COM2 COM1 Serial Port Header FAN 1 9 Chassis CPU Fan Headers Floppy Floppy Disk Drive Connector I Button I Button for RAID 5 support IDE IDE Drive Compact Flash Card Connector J1B1...

Страница 12: ...1 PCI Express x4 slot x8 slot using x4 signal One 1 PCI X 133 100 MHz slot One 1 SIMLC slot for IPMI card BIOS 8 Mb AMIBIOS LPC Flash ROM DMI 2 3 PCI 2 2 ACPI 2 0 SMBIOS 2 3 Plug and Play PnP PC Healt...

Страница 13: ...ght 8 SAS ports RAID 0 1 10 and JBOD optional RAID 5 support with iButton installed H8QM3 2 only One 1 UltraDMA ATA 133 100 IDE port One 1 oppy port interface Two 2 Fast UART 16550 compatible serial p...

Страница 14: ...GHz DDR2 667 533 400 DDR2 667 533 400 SATA Ports 6 IDE ATA133 USB Ports 4 S I O BIOS Floppy Kybd Mouse Serial Ports 2 AMD Socket F Type Processor CPU1 PCI E LPC ATI ES 1000 nVidia IO55 AMD Socket F Ty...

Страница 15: ...nterface and a USB 2 0 interface This hub connects directly to CPU1 IO55 This hub connects directly to CPU2 via a 16 x 16 1 GHz Hyper Transport link The IO55 includes an interface for the PCI Express...

Страница 16: ...onboard fans are controlled by thermal management via BIOS CPU Overheat Fan Fail LED and Control This feature is available when the user enables the CPU overheat Fan Fail warning function in the BIOS...

Страница 17: ...provides power to keep the required circuitry in the system alive In case the system malfunctions and you want to turn off the power just depress and hold the power button for 4 seconds The power wil...

Страница 18: ...data separator write pre compensation circuitry decode logic data rate selection a clock genera tor drive interface control logic and interrupt and DMA logic The wide range of functions integrated ont...

Страница 19: ...d and peripherals back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting...

Страница 20: ...he CPU1 socket For a dual CPU con guration install to the CPU1 and CPU2 sockets Exercise extreme caution when handling and installing the proces sor Always connect the power cord last and always remov...

Страница 21: ...the four corners of the CPU to make sure that it is properly in stalled and ush with the socket Then gently lower the silver CPU retention plate into place 5 Carefully press the CPU socket le ver down...

Страница 22: ...doffs in the tray Insert screws into all the mounting holes in the serverboard that line up with the standoffs Then use a screwdriver to secure the serverboard to the mainboard tray tighten until just...

Страница 23: ...with memory modules of the same size and type will result in inter leaved 128 bit memory which is faster than non interleaved 64 bit memory Optimizing memory performance It is better to spread pairs o...

Страница 24: ...ious I O ports Figure 2 3 I O Port Locations and De nitions Front Control Panel JF1 contains header pins for various front control panel connectors See Figure 2 4 for the pin de nitions of the various...

Страница 25: ...COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Processor Power Connectors In addition to the primary ATX power connector above the 8 pin proces sor power connectors...

Страница 26: ...on the right for pin de nitions OH Fan Fail LED Pin De nitions JF1 Pin De nition 7 Vcc 8 Control NIC1 LED Pin De nitions JF1 Pin De nition 11 Vcc 12 NIC1 Active NIC2 LED Pin De nitions JF1 Pin De nit...

Страница 27: ...Serial Bus Ports USB0 1 Two Universal Serial Bus ports USB2 0 are located beside the key board mouse ports See the table on the right for pin de nitions Reset Button Pin De nitions JF1 Pin De nition...

Страница 28: ...nd 10 NC Fan Header Pin De nitions FAN1 9 Pin De nition 1 Ground Black 2 12V 9V Red 3 Tachometer Note Fan speed may controlled by a BIOS setting to change with system temperature As a result pin 2 may...

Страница 29: ...1 Intrusion Input 2 Ground Wake On LAN The Wake On LAN header is desig nated JWOL See the table on the right for pin definitions You must have a LAN card with a Wake On LAN connector and cable to use...

Страница 30: ...IO2 The 3 SGPIO1 and 3 SGPIO2 head ers provide a bus between the SAS controller and the drive backplane to provide SAS enclosure manage ment functions Connect cables from the backplane to the these he...

Страница 31: ...the PW_ON connector to clear CMOS The onboard battery does not need to be removed when clearing CMOS however you must short JBT1 for at least four seconds JBT1 contact pads 2 7 Jumper Settings Explana...

Страница 32: ...set to the enabled or disabled set ting for this feature to function See the table on the right for jumper settings I2 C to PCI X Slots Jumper Settings JI2 C1 JI2 C2 Jumper Setting De nition Pins 1 2...

Страница 33: ...Speed Jumpers JPX1A and JPX2A can be used to change the speed of the PCI X slot 1 Note that any JPX2A setting overrides all JPX1A settings To use a JPX1A setting JPX2A should be left open See the tab...

Страница 34: ...off Be sure to turn off the system and unplug the power cord s before removing or installing components Flashing IT Firmware 1 Download the appropriate IT rmware from the web site ftp ftp supermicro...

Страница 35: ...ould be used to take advantage of the speed this new technology offers The blue connector connects to the onboard IDE connector interface and the other connector s to your hard drive s Consult the doc...

Страница 36: ...t Data 12 13 Host Data 2 14 Host Data 13 15 Host Data 1 16 Host Data 14 17 Host Data 0 18 Host Data 15 19 Ground 20 Key 21 DRQ3 22 Ground 23 I O Write 24 Ground 25 I O Read 26 Ground 27 IOCHRDY 28 BAL...

Страница 37: ...ons Note refer to the FAQ section in Chapter 3 for details on en abling SAS SIMLC IPMI Slot The SIMLC slot on the H8QM3 2 and H8QMi 2 is reserved for an optional IPMI card Note with an IPMI card in st...

Страница 38: ...below and install the driver during the OS installation Note the SATA RAID driver is supported by Windows 2000 and XP only Building a Driver Diskette You must rst build a driver diskette from the CD...

Страница 39: ...y press the F7 key You will be prompted to verify your choice if you want to continue with your choices select Yes Note that selecting Yes will clear all previous data from the drives you selected to...

Страница 40: ...2 22 H8QM3 2 H8QMi 2 User s Manual Figure 2 5 SATA RAID Utility Main Screen Figure 2 6 SATA RAID Utility Array List...

Страница 41: ...mputer icon and then on the icon representing your CD ROM drive Finally double click on the S Setup icon Click the icons showing a hand writing on paper to view the readme les for each item Click the...

Страница 42: ...2 24 H8QM3 2 H8QMi 2 User s Manual Notes...

Страница 43: ...hose for the keyboard and mouse 5 Remove all add on cards 6 Install CPUs and heatsinks making sure they are fully seated and connect the internal chassis speaker and the power LED to the serverboard C...

Страница 44: ...n Refer to Sec tion 1 6 for details on recommended power supplies 2 The battery on your serverboard may be old Check to verify that it still supplies 3VDC If it does not replace it with a new one 3 If...

Страница 45: ...ded that you not upgrade your BIOS if you are not experi encing problems with your system Updated BIOS les are located on our web site Please check our BIOS warning message and the information on how...

Страница 46: ...the ATA133 technology offers Connect the blue connector to the onboard IDE header and the other connector s to your hard drive s Consult the documentation that came with your disk drive for details o...

Страница 47: ...F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be con gured Grayed out options cannot be co...

Страница 48: ...be entered in DAY MM DD YYYY format The time is entered in HH MM SS format Please note that time is in a 24 hour format For example 5 30 A M appears as 05 30 00 and 5 30 P M as 17 30 00 4 3 Advanced S...

Страница 49: ...bled and Disabled Interrupt 19 Capture Select Enabled to allow ROMs to trap Interrupt 19 The options are Enabled and Disabled OS Installation Change this setting if using a 64 bit Linux operating syst...

Страница 50: ...n unexpected loss of power The options are Power Off Power On and Last State Watch Dog Timer This setting is used to Enable or Disable the Watch Dog Timer function It must be used in conjunction with...

Страница 51: ...ing This setting is used to Enable or Disable Thermal Throttling Floppy IDE SATA Con guration Floppy A Move the cursor to these elds via up and down arrow keys to select the oppy type The options are...

Страница 52: ...per interrupt if block mode is not used Block mode allows transfers of up to 64 KB per interrupt Select Disabled to allow the data to be transferred from and to the device one sector at a time Select...

Страница 53: ...activate the function of 32 Bit data transfer Select Disabled to deactivate the function The options are Enabled and Disabled Serial ATA0 1 2 Primary Secondary Channel Highlight one of the items above...

Страница 54: ...ROM drives check the speci cations of the drive DMA Mode Selects the DMA Mode Options are SWDMA0 SWDMA1 SWDMA2 MWDMA0 MDWDMA1 MWDMA2 UDMA0 UDMA1 UDMA2 UDMA3 UDMA4 and UDMA5 SWDMA Single Word DMA MWDM...

Страница 55: ...errupt address The options are Yes and No Palette Snooping Select Enabled to inform the PCI devices that an ISA graphics device is installed in the system in order for the graphics card to function pr...

Страница 56: ...ddress This option speci es the base I O port address and Interrupt Request address of serial port 1 Select Disabled to prevent the serial port from accessing any system resources When this option is...

Страница 57: ...Enable Clock to All DIMMs Use this setting to enable unused clocks to all DIMMs even if some DIMM slots are unpopulated Options are Enabled and Disabled Mem Clk Tristate C3 ALTVID Use this setting to...

Страница 58: ...conds and microseconds L2 Cache BG Scrub Allows L2 cache RAM to be corrected when idle Options are Disabled and various times in nanoseconds and microseconds Data Cache BG Scrub Allows L1 cache RAM to...

Страница 59: ...r disable the USB 1 1 controller USB 2 0 Controller Enable or disable the USB 2 0 controller USB Devices Enabled This eld dsiplays the USB devices currently enabled Legacy USB Support Select Enabled t...

Страница 60: ...n Remote Access Allows you to Enable or Disable remote access If enabled the settings below will appear Serial Port Number Selects the serial port to use for console redirection Options are COM1 and C...

Страница 61: ...eshold set The default setting is 72o C Other items in the submenu are systems monitor displays for the following in formation CPU1 Temperature CPU2 Temperature CPU3 Temperature CPU4 Temperature for 4...

Страница 62: ...Device Hard Disk Drives This feature allows the user to specify the boot sequence from available hard disk drives 1st Drive Speci es the boot sequence for the 1st Hard Drive Hard Disk Drives This feat...

Страница 63: ...ord Select this option and press Enter to access the sub menu and then type in the password Boot Sector Virus Protection This option is near the bottom of the Security Setup screen Select Disabled to...

Страница 64: ...n and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Discard Changes Select this option and press Enter to discard all the changes and return to AMI BIOS Utilit...

Страница 65: ...ally communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed with the e...

Страница 66: ...A 2 H8QM3 2 H8QMi 2 User s Manual Notes...

Страница 67: ...s are listed in order of execution Checkpoint Code Description D0h The NMI is disabled Power on delay is starting Next the initialization code check sum will be veri ed D1h Initializing the DMA contro...

Страница 68: ...occurred while reading the oppy drive in drive A F0h Next searching for the AMIBOOT ROM le in the root directory F1h The AMIBOOT ROM le is not in the root directory F2h Next reading and analyzing the...

Страница 69: ...d during power on Initializing CMOS RAM if the Initialize CMOS RAM in every boot AMIBIOS POST option was set in AMIBCP or the End key was pressed 12h Next disabling DMA controllers 1 and 2 and interru...

Страница 70: ...PL general devices next if present See the last page of this chapter for additional information 39h Displaying bus initialization error messages See the last page of this chapter for additional inform...

Страница 71: ...was adjusted for relocation and shadowing Clearing the Hit DEL message next 59h The Hit DEL message is cleared The WAIT message is displayed Starting the DMA and interrupt controller test next 60h The...

Страница 72: ...ontrol and has now returned control to BIOS POST Perform ing any required processing after the option ROM returned control 99h Any initialization required after the option ROM test has completed Con g...

Страница 73: ...option ROM had control next Aah Initialization after E000 option ROM control has completed Displaying the system con guration next Abh Uncompressing the DMI data and executing DMI POST initialization...

Страница 74: ...B 8 H8QM3 2 H8QMi 2 User s Manual Notes...

Отзывы: