background image

®

S

UPER

S

TORAGE 

S

YSTEM

 

5028R-E1CR12L

   

S

UPER

USER’S MANUAL

 

1.0

Проконсультироваться

 

и

 

купить

 

данное

 

оборудование

 

вы

 

можете

 

в

 

компании

 «

АНД

-

Системс

»  

адрес

: 125480, 

г

.

Москва

ул

.

Туристская

д

.33/1; site: https://andpro.ru 

тел

: +7 (495) 545-4870 email: [email protected] 

При

 

обращении

 

используйте

 

промокод

 AND-PDF 

и

 

получите

 

скидку

Содержание 5028R-E1CR12L

Страница 1: ...SUPERSTORAGE SYSTEM 5028R E1CR12L SUPER USER S MANUAL 1 0 125480 33 1 site https andpro ru 7 495 545 4870 email info andpro ru AND PDF...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...e SC826BE1C R920LPB chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the 5028R E1CR12L into a rack and check out the server configuration prior to powering u...

Страница 4: ...iguring the motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC826BE1C R920LPB chassis You should follow the procedures given in this chapter when instal...

Страница 5: ...Notes Preface v...

Страница 6: ...ver Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 2...

Страница 7: ...Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning 4 16 Power Cable and AC Adapter 4 18 Chapter 5 Advanced Serverboard Setup 5 1 Handling the Serverboard 5 1 Precautions 5 1 Unpacking 5 1 5 2 Proce...

Страница 8: ...ns 6 4 6 5 Air Shroud 6 5 6 6 Drive Bay Installation Removal 6 6 Accessing the Drive Bays 6 6 SATA Drive Installation 6 6 Hard Drive Backplane 6 8 6 7 Power Supply 6 9 Power Supply Failure 6 9 Removin...

Страница 9: ...PU heatsink SNK P0048PS Three 8 cm system fans FAN 0126L4 One air shroud MCP 310 29001 0N SATA Accessories One SATA backplane BPN SAS3 826EL1 Twelve drive carriers MCP 220 00075 0B One rackmount kit M...

Страница 10: ...load reduced DIMMs LRDIMMs DDR4 1866 1600 1333 1066 800 DDR3 memory Please refer to Chapter 5 for installing memory SATA An on chip SATA controller is integrated into the X10SRH CLN4F to provide ten S...

Страница 11: ...ed to support 12 hot swap hard drives Two 2 5 rear mounted hot swap drive bays are available as an option for use with the onboard SATA controller MCP 220 82609 0N These drives install between the pow...

Страница 12: ...SMBUS TPM HEADER USB 3 0 USB AST2400 BMC 5 6 7 RMII NCSI COM1 Connector COM2 Header VGA CONN BMC Boot Flash DDR3 5 PHASE 145W VR12 5 Haswell PCI E X8 Gen3 DMI2 PCI E X8 Gen3 PCI E X8 Gen3 DMI2 Skt R3...

Страница 13: ...WER POWER SATA DOM UID LED X LED 2 3 DISABLE 1 2 ENABLE JPS1 SAS 1 2 ENABLE 2 3 DISABLE LAN2 LAN4 L SAS4 7 L SAS0 3 1 2 ENABLE 2 3 DISABLE JPB1 BMC CPU CPU SLOT6 PCI E 3 0 X8 IN X16 CPU SLOT5 PCI E 3...

Страница 14: ...ro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support...

Страница 15: ...suitable location for the rack unit that will hold the 5028R E1CR12L It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagneti...

Страница 16: ...s make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Ser...

Страница 17: ...oom Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient tempera ture Tmra Airflow Equipment should be mounted...

Страница 18: ...erver chassis and an outer fixed rack rail that secures directly to the rack itself Installing the Inner Rail Extension The SC826 chassis includes a set of inner rails in two sections inner rails and...

Страница 19: ...ter Rails 1 Locate the rail assembly in the chassis packaging 2 Extend the rail assembly by pulling it outward 3 Press the quick release tab 4 Separate the inner rail extension from the outer rail ass...

Страница 20: ...r rails are joined to retract the smaller outer rail 3 Hang the hooks of the rails onto the rack holes and if desired use screws to secure the front of the outer rail onto the rack 4 Repeat steps 1 3...

Страница 21: ...uter rails as illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the ch...

Страница 22: ...2 8 SUPERSTORAGESYSTEM 5028R E1CR12L User s Manual Notes...

Страница 23: ...of specific components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons There are two buttons located on the front of the chassis a reset button and a power on off bu...

Страница 24: ...eplacing the power supply This LED should be off when the system is operating normally Overheat Fan Fail When this LED flashes it indicates a fan failure When on continuously it indicates an overheat...

Страница 25: ...uminated the green LED on the SATA drive carrier indicates drive activity A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed Please re...

Страница 26: ...3 4 SUPERSTORAGESYSTEM 5028R E1CR12L User s Manual Notes...

Страница 27: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 28: ...uipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encont...

Страница 29: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 30: ...schlie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de br...

Страница 31: ...rt ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes del...

Страница 32: ...ckgreift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessi...

Страница 33: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 34: ...nt Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplaza...

Страница 35: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 36: ...he same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met...

Страница 37: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 38: ...xi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour su...

Страница 39: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Страница 40: ...al electrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales...

Страница 41: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Страница 42: ...debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseigne...

Страница 43: ...dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilat...

Страница 44: ...und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r all...

Страница 45: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Страница 46: ...4 20 SUPERSTORAGESYSTEM 5028R E1CR12L User s Manual Notes...

Страница 47: ...that the size and weight of the motherboard can cause it to bend if handled improperly which may result in damage To prevent the motherboard from bending keep one hand under the center of the board t...

Страница 48: ...to the chassis before you install the CPU heatsinks When receiving a motherboard without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are...

Страница 49: ...remove the WARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are a...

Страница 50: ...load plate again and double check that the CPU is aligned properly 7 With the CPU in the socket in spect the four corners of the CPU to make sure that they are flush with the socket 8 Close the load...

Страница 51: ...screws then fully tighten all four screws Removing the Heatsink Caution We do not recommend removing the heatsink However if you do need to remove it follow the instructions below to prevent damage to...

Страница 52: ...ons Control Panel cable JF1 see next page SATA or SAS cables I SATA0 I SATA5 L SATA0 L SATA7 Connecting Power Cables The X10SRH CLN4F has a 24 pin primary power supply connector designated J24 for con...

Страница 53: ...I O Ports Backplane I O Ports 1 COM1 Port 7 LAN Port 3 2 IPMI LAN 8 LAN Port 1 3 USB Port 1 USB 2 0 9 LAN Port 4 4 USB Port 1 USB 2 0 10 LAN Port 2 5 USB Port 3 USB 3 0 11 VGA Port 6 USB Port 2 USB 3...

Страница 54: ...e slot Repeat step 1 to install additional DIMMs Memory Support The X10SRH CLN4F has eight DIMM sockets that can support up to 256 GB of RDIMM registered DIMM or 512 GB of load reduced DIMMs LRDIMMs D...

Страница 55: ...hysical Memory Remaining Available 4 GB Total System Memory Firmware Hub flash memory System BIOS 1 MB 3 99 Local APIC 4 KB 3 99 Area Reserved for the chipset 2 MB 3 99 I O APIC 4 Kbytes 4 KB 3 99 PCI...

Страница 56: ...stem can support up to five low profile add on PCI expansion cards Add on Card Installation Begin by releasing the locking tab that corresponds to the slot you wish to populate Insert the add on card...

Страница 57: ...X8 CPU SLOT4 PCI E 3 0 X8 PCH SLOT3 PCI E 2 0 X2 IN X4 JPME2 2 3 ME MANUFACTURING MODE 1 2 Normal USB0 1 DIMMC2 PWR LED 1 3 JD1 SPEAKER 4 7 JBR1 1 2 Normal 2 3 BIOS recovery TPM PRO80 CHASSIS INTRUSIO...

Страница 58: ...I_LAN Dedicated IPMI LAN I SATA0 3 SATA 3 0 Ports I SATA4 5 SATA DOM Device On Module Ports S SATA0 3 SATA 3 0 Ports L SAS 0 3 4 7 SAS 3 0 Ports 0 7 supported by LSI 3008 controller PCH Slot 2 3 PCI E...

Страница 59: ...pin definitions ATX Power 24 pin Connector Pin Definitions JPW1 Pin Definition Pin Definition 13 3 3V 1 3 3V 14 12V 2 3 3V 15 COM 3 COM 16 PS_ON 4 5V 17 COM 5 COM 18 COM 6 5V 19 COM 7 COM 20 Res NC 8...

Страница 60: ...Connect an LED cable to pins 7 and 8 of JF1 to use the Overheat Fan Fail Power Fail and UID LED connections The red LED on pin 7 provides warnings of overheat fan failure or power failure The blue LED...

Страница 61: ...n for 4 seconds or longer Refer to the table on the right for pin definitions Power Button Pin Definitions JF1 Pin Definition 1 Signal 2 Ground Serial Ports The COM1 port is located next to USB0 1 The...

Страница 62: ...ID Switch Pin Definition 1 Ground 2 Ground 3 Button In 4 Ground UID LED LED3 Status Color State Status Blue On Unit Identified Universal Serial Bus USB Four Universal Serial Bus ports USB 0 1 2 3 are...

Страница 63: ...Pin Definitions Pin Definition 1 Ground 2 12V 3 Tachometer 4 PWR Modulation Power LED Speaker On JD1 header pins 1 3 are used for power LED indication and pins 4 7 are for the speaker See the tables...

Страница 64: ...n Definitions Pin Definition 1 5vDC 2 OH Active OH Fan Fail LED Status State Message Solid Overheat Blinking Fan Fail Trusted Platform Module Header The JTPM1 header is used to connect a Trusted Platf...

Страница 65: ...ck 8 NC T SGPIO 1 2 Headers Three T SGPIO Serial Link General Purpose Input Output headers are located near the SATA connectors on the motherboard These headers are used to communicate with the enclos...

Страница 66: ...is used to clear CMOS and will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down the...

Страница 67: ...inition Pins 1 2 Enabled Pins 2 3 Disabled PCI Slot SMB Enable Disable Jumper Settings Setting Definition Closed Enabled Open Disabled PCI Slot SMB Enable Use jumpers JI2 C1 JI2 C2 to enable PCI E SMB...

Страница 68: ...tes the speed of the connection See the table at right for more information Manufacture Mode Select Close jumper JPME2 to bypass SPI flash security and force the system to use the Manufacture Mode whi...

Страница 69: ...al 5 11 SATA Drive Ports SATA SAS Port Pin Definitions Pin Definition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground SATA Ports There are ten SATA 3 0 ports on the X10SRH CLN4F In addition to SATA...

Страница 70: ...referred Another option is to go to the Supermicro Website at http www supermicro com products Find the product page for your motherboard here where you may down load individual drivers and utilities...

Страница 71: ...nt versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Man agement Server SSM Server you can remotely control power on off and reset chassis intrusion for...

Страница 72: ...attery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by...

Страница 73: ...em very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded...

Страница 74: ...the airflow path The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons Details on JF1 can be found in Chapter 5 6 3 Accessing the Inside of the Chas...

Страница 75: ...n fails the remaining fans will ramp up to full speed and the overheat fan fail LED on the control panel will turn on Replace any failed fan at your earliest convenience with the same type and model t...

Страница 76: ...o the system and unplug the system from the outlet 3 Remove the failed fan s power cord from the motherboard 4 Press the fan release tab to lift the failed fan from the chassis and pull it completely...

Страница 77: ...ling the Air Shroud 1 Lay the chassis on a flat stable surface and remove the chassis cover 2 If necessary move any cables that interfere with the air shroud placement 3 Place the air shroud in the ch...

Страница 78: ...oper airflow for the drives For this reason even empty carriers without hard drives installed must remain in the chassis Removing a Drive Carrier 1 Push the release button located beside the drive s L...

Страница 79: ...Advanced Chassis Setup 6 7 1 2 1 2 Figure 6 5 Removing a Hard Drive Carrier Caution Regardless of how many hard drives are installed all drive carriers must remain in the drive bays to maintain prope...

Страница 80: ...ESS FIT CG5 CG2 A1 A2 A7 A8 CG1 B1 B2 B7 B8 C1 C2 C7 C8 D1 D2 D7 D8 CG4 E1 E2 G2 F2 F1 H2 H1 G1 F7 F8 G8 E7 G7 H7 H8 E8 PRESS FIT CG5 CG2 A C A C A C A C A C 3 2 1 4 3 2 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1...

Страница 81: ...rom Supermicro The power supply units have a hot swap capability meaning you can replace the failed unit without powering down the system Removing Replacing the Power Supply You do not need to shut do...

Страница 82: ...6 10 SUPERSTORAGESYSTEM 5028R E1CR12L User s Manual Release Tab Figure 6 8 Removing the Power Supply...

Страница 83: ...SSG 5028R E1CR12L features a single JBOD expansion port The JBOD at tachment will vary depending on the specific JBOD chassis that is being connected The JBOD image below is provided for illustrative...

Страница 84: ...6 12 SUPERSTORAGESYSTEM 5028R E1CR12L User s Manual Notes...

Страница 85: ...t can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text me...

Страница 86: ...arning Do not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect...

Страница 87: ...DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X10SRH CLN4F Version This item displays the version of...

Страница 88: ...et Boot Use this feature to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the...

Страница 89: ...uration DeepSx Power Policies Use this item to configure the Advanced Configuration and Power Interface ACPI settings for the system Enable S3 to use Standby Mode Suspend to RAM and maintain power sup...

Страница 90: ...lock Spread Spectrum Select Enabled to allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the components whenever needed The options are Disabled and E...

Страница 91: ...e and Unlock Disable Hardware Prefetcher Available when supported by the CPU If set to Enable the hardware prefetcher will prefetch streams of data and instruc tions from the main memory to the L2 cac...

Страница 92: ...Ds APIDs in 8 bit bandwidth When this feature is set to En able the APIC ID will be expanded X2 from 8 bits to 16 bits to provide 512 APIDs to each thread to enhance CPU performance The options are Di...

Страница 93: ...e to boost system performance The options are Enable and Disable P state Coordination This feature is used to change the P state Power Performance State coordi nation type P state is also known as Spe...

Страница 94: ...rating system to reduce power consumption The options are Enable and Disable Socket RAPL Running Average Power Limit Configuration FAST_RAPL_NSTRIKE_PL2_DUTY_CYCLE This feature displays the value of t...

Страница 95: ...essor operating in turbo mode with P0 being the state with the highest frequency clock speed and power consumption and P1 a step lower in performance than P0 with its frequency and voltage scaled back...

Страница 96: ...ecified by the user The options are Gen 1 Generation 1 2 5 GT s Gen 2 Generation 2 5 GT s and Gen 3 Generation 3 8 GT s IOU1 II0 PCIE Port 3 Use this item to configure the PCI E port Bifuraction setti...

Страница 97: ...O VT d Intel VT for Direct I O VT d Intel VT for Directed I O VT d Select Enable to use Intel Virtualization Technology support for Direct I O VT d support by reporting the I O device assignments to...

Страница 98: ...item to select the desired frequency for QPI Link connections The op tions are 6 4GB s 8 0GB s 9 6GB s Auto and Auto Limited Link L0p Enable Select Enable for Link L0p support The options are Enable a...

Страница 99: ...d Enable ADR Select Enabled for ADR Automatic Diagnostic Repository support to enhance memory performance The options are Enabled and Disabled DRAM RAPL Baseline Use this feature to set the run time p...

Страница 100: ...1 P2 DIMMA2 P2 DIMMD2 Memory RAS Reliability_Availability_Serviceability Configuration Use this submenu to configure the following Memory RAS settings RAS Mode When Disable is selected RAS is not supp...

Страница 101: ...ub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module When the CPU or I O issues a demand read command and the read data from memory turns...

Страница 102: ...support for the operating systems that do not support legacy USB devices The options are Disabled and Enabled USB 3 0 Support Select Enabled for USB 3 0 support The options are Smart Auto Auto Enabled...

Страница 103: ...onfigure SATA as is set to AHCI the following items will display Support Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SATA...

Страница 104: ...0 Port 5 This item indicates that a SATA port specified by the user is installed present or not Port 0 Port 5 SATA Device Type Available when a SATA port is detected Use this item to specify if the SA...

Страница 105: ...e device The options are Enabled and Disabled Port 0 Port 5 SATA Device Type Use this item to specify if the SATA port specified by the user should be con nected to a Solid State drive or a Hard Disk...

Страница 106: ...n sSATA port specified by the user The options are Disabled and Enabled sSATA Port 0 Port 3 Hot Plug Select Enabled to enable hot plugging support for a port specified by the user which will allow the...

Страница 107: ...legacy driver for system boot The options are Disabled EFI and Legacy sSATA Port 0 Port 3 This item displays the information detected on the installed sSATA drives on the particular sSATA port Model...

Страница 108: ...ing which will allow a PCI card that does not contain its own VGA color palette to examine a video card pal ette and mimic it for proper color display The options are Disabled and Enabled PCI AER Adva...

Страница 109: ...he base memory size according to memory address map ping for the IO hub The base memory size must be between 4032G to 4078G The options are 56T 48T 24T 512G and 256G MMIO High Size Use this item to se...

Страница 110: ...k is set to Enabled Select Enabled to enable Ipv4 PXE Preboot Execution Environment for boot sup port If this feature is set to Disabled Ipv4 PXE boot option will not be supported The options are Enab...

Страница 111: ...COM Port 2 as a Serial_Over_LAN SOL port for console redi rection The options are COM and SOL Serial Port Console Redirection COM 1 COM 1 Console Redirection Select Enabled to enable COM Port 1 Consol...

Страница 112: ...A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control Use thi...

Страница 113: ...OM2 Console Redirection Settings Use this feature to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Terminal Type Use this feat...

Страница 114: ...l for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start data sending when the re...

Страница 115: ...to be used by the Windows Emergency Management Services EMS to communicate with a remote host server The options are COM1 Console Redirection and COM2 SOL Console Redirection Terminal Type Use this f...

Страница 116: ...ease reboot the system for a change on this setting to take effect The options are Enabled and Disabled TPM State Select Enabled to use TPM Trusted Platform Module settings to enhance system data secu...

Страница 117: ...gh Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback and reducing th...

Страница 118: ...d and Disabled Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are Enabled and Disabled If this item is set to Enable the following item will be available for...

Страница 119: ...SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Count Increment Enter the increment value fo...

Страница 120: ...installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled to enable all system event logging support at bootup The options are Enabled and Disabled Erasing Set...

Страница 121: ...P address source for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected AMI BIOS will search...

Страница 122: ...assword at bootup and upon entering the BIOS Setup utility The options are Setup and Always Administrator Password Use this feature to set the administrator password which is required before entering...

Страница 123: ...starts to boot The default setting is 1 Boot Mode Select Use this item to select the type of device to be used for system boot The options are Legacy UEFI and Dual Fixed Boot Order Priorities This op...

Страница 124: ...to specify the name of the driver that the new boot option is added to Path for Boot Option This item is used to specify the path to the driver that the new boot option is added to The format for the...

Страница 125: ...r 7 BIOS 7 41 Hard Disk Drive BBS Priorities Legacy Boot Order 1 Legacy Boot Order 10 Network Drive BBS Priorities Legacy Boot Order 1 Legacy Boot Order 3 UEFI Application Boot Priorities UEFI Boot Or...

Страница 126: ...ter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configura tion paramet...

Страница 127: ...rom the Exit menu and press En ter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu...

Страница 128: ...7 44 SUPERSTORAGESYSTEM 5028R E1CR12L User s Manual Notes...

Страница 129: ...a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error...

Страница 130: ...A 2 SUPERSTORAGESYSTEM 5028R E1CR12L User s Manual Notes...

Страница 131: ...M or 512 GB of load reduced DIMMs LRDIMMs DDR4 1866 1600 1333 1066 800 DDR3 memory Note See the memory section in Chapter 5 for details SATA Controller Intel on chip controller for ten SATA 3 0 ports...

Страница 132: ...sing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 5...

Страница 133: ...o perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell su...

Страница 134: ...B 4 SUPERSTORAGESYSTEM 5028R E1CR12L User s Manual Notes...

Отзывы: