SUPERSERVER 2015TA-HTRF User's Manual
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front
•
door completely (~25 inches).
Leave approximately 30 inches of clearance in the back of the rack to allow for
•
suf
fi
cient air
fl
ow and ease in servicing.
This product is for installation only in a Restricted Access Location (dedicated
•
equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices accord-
•
ing to §2 of the the German Ordinance for Work with Visual Display Units.
!
!
Warnings and Precautions!
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
•
the
fl
oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack.
•
In multiple rack installations, the racks should be coupled together.
•
Always make sure the rack is stable before extending a component from it.
•
You should extend only one component at a time - extending two or more si-
•
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
•
Determine the placement of each component in the rack
•
before
you install the
rails.
Install the heaviest server components on the bottom of the rack
fi
rst, and then
•
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
•
power surges, voltage spikes and to keep your system operating in case of a
power failure.
Содержание 2U Twin3 SuperServer 2015TA-HTRF
Страница 1: ...SUPER USER S MANUAL Revision 1 0 2U Twin3TM SuperServer 2015TA HTRF ...
Страница 5: ...v Preface Notes ...
Страница 25: ...Chapter 2 Server Installation 2 11 Figure 2 6 Removing a Node from the System ...
Страница 26: ...2 12 SUPERSERVER 2015TA HTRF User s Manual Notes ...
Страница 30: ...3 4 SUPERSERVER 2015TA HTRF User s Manual Notes ...
Страница 54: ...5 20 SUPERSERVER 2015TA HTRF User s Manual Notes ...
Страница 64: ...6 10 SUPERSERVER 2015TA HTRF User s Manual Figure 6 7 Removing the Power Supply Release Tab ...
Страница 88: ...7 24 SUPERSERVER 2015TA HTRF User s Manual Notes ...
Страница 90: ...A 2 SUPERSERVER 2015TA HTRF User s Manual Notes ...
Страница 93: ...B 3 Appendix B System Specifications Notes ...