Supermicro X11DPT-B Скачать руководство пользователя страница 1

USER’S MANUAL 

Revision 1.1c

X11DPT-B

Содержание X11DPT-B

Страница 1: ...USER S MANUAL Revision 1 1c X11DPT B...

Страница 2: ...an industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful...

Страница 3: ...flexibility This motherboard is ideal for high performance server platforms Please note that this motherboard is intended to be installed and serviced by professional technicians only For processor me...

Страница 4: ...ages Appendix D contains UEFI BIOS Recovery instructions Appendix E provides information on how to configure VROC RAID settings Appendix F provides information on how to configure secure boot settings...

Страница 5: ...r B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supe...

Страница 6: ...22 2 3 Processor and Heatsink Installation 24 2 4 Memory Support and Installation 32 2 5 Rear I O Ports 41 2 6 Front Control Panel 45 2 7 Headers 46 2 8 Jumper Settings 51 2 9 LED Indicators 53 2 10...

Страница 7: ...ge 140 D 3 Recovering the Main BIOS Block with a USB Device 141 Appendix E Configuring VROC RAID Settings E 1 All Intel VMD Controllers Menu 145 E 2 Configuring RAID Settings 149 E 3 Use of Journaling...

Страница 8: ...and utilities http www supermicro com wftp Product safety info http www supermicro com about policies safety_information cfm A secure data deletion tool designed to fully erase all data from storage...

Страница 9: ...ard Image Note All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual The motherboard you received may or may not look exactly the...

Страница 10: ...JF1 JF2 JNVI2C1 JTPM1 JSD1 CPU1 PCI E 3 0 X4 CPU2 PCI E 3 0 X24 I SATA0 5 P2 DIMMF2 P2 DIMMF1 P2 DIMMD1 P2 DIMME1 P2 DIMME2 P2 DIMMD2 P2 DIMMC2 P2 DIMMC1 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2 DIMMB2 P1 DIM...

Страница 11: ...MI_LAN CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW VGA CPU2 SLOT2 PCI E 3 0 X16 JSD1 SATA DOM POWER CPU1 P1 DIMMD1 P1 DIMMD2 P1 DIMME1 P1 DIMME2 P1 DIMMA1 P1 DIMMA2 P1 DIMMB1 P1 DIMMB2 JVRM1 JPB1 JPG1 J...

Страница 12: ...ATA6 Powered SATA connector w power pin built in with support of Supermicro SuperDOM Disk On Module UID SW UID switch USB0 1 Back panel USB 3 0 ports VGA Back panel VGA port VROC JRK1 Intel VROC RAID...

Страница 13: ...l Xeon Scalable SP processors only DIMM Size Up to 256 GB at 1 2V Note 1 Memory speed support depends on the processors used in the system Note 2 For the latest CPU memory updates please refer to our...

Страница 14: ...12V 3 3V standby 5V standby HT memory PCH temperature system temperature and memory temperature CPU 8 phase switching voltage regulator CPU thermal trip support Status monitor for on off control CPU...

Страница 15: ...proper CPU TDP sizing Note 2 For IPMI configuration instructions please refer to the Embedded IPMI Con figuration User s Guide available at http www supermicro com support manuals Note 3 It is strongl...

Страница 16: ...ESPI Temp Sensor NCT7718W USB 3 0 SPI AST2500 BMC 5 RMII NCSI COM1 Connector VGA CONN BMC Boot Flash DDR4 5 1 PHASE 205W P1 P1 P0 VR13 P0 UPI PCI E X16 DMI3 SXB1 M 2 PCI E X4 PCI E X16 UPI 10 4 11 2G...

Страница 17: ...nt with Intel Volume Management Device Intel VMD Rich set of available IOs with increased PCIe lanes 48 lanes Integrated Intel Ethernet Connection X722 with iWARP RDMA New features supported by 2nd Ge...

Страница 18: ...C chip that supports system health monitoring Onboard Voltage Monitors The onboard voltage monitor will continuously scan crucial voltage levels Once a voltage becomes unstable it will give a warning...

Страница 19: ...ing system independent interface for configuration control ACPI leverages the Plug and Play BIOS data structures while providing a processor architecture independent implementation that is compatible...

Страница 20: ...processors support new DCPMM Optane DC Persistent Memory Modules technology that offers data persistence with higher capacity than existing memory modules and lower latency than NVMe SSDs DCPMM memory...

Страница 21: ...s only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antista...

Страница 22: ...s Please take precau tionary measures to avoid damaging these components when installing the mother board to the chassis Phillips Screwdriver 1 Standoffs 12 Only if Needed Phillips Screws 12 Tools Nee...

Страница 23: ...tandoffs in the chassis as needed 5 Install the motherboard into the chassis carefully to avoid damaging other motherboard components 6 Using the Phillips screwdriver insert a Phillips head 6 screw in...

Страница 24: ...ll the CPU heatsink If you buy a CPU separately make sure that you use an Intel certified multi directional heatsink only Make sure to install the motherboard into the chassis before you install the C...

Страница 25: ...el Xeon Scalable SP or 2nd Generation Intel Xeon Scalable SP processor 2 CPU heatsink carrier 3 dust cover and 4 CPU socket 3 Dust Cover 4 CPU Socket 1 Intel Processor CPU Socket Assembly W A R N I N...

Страница 26: ...ule The processor heatsink module PHM contains 1 a passive heatsink 2 a CPU heatsink carrier and 3 Intel Xeon Scalable SP or 2nd Generation Intel Xeon Scalable SP processor 1 Passive Heatsink 2 CPU He...

Страница 27: ...the CPU socket and 4 a back plate These components are pre installed on the motherboard before shipping Processor Socket Assembly Socket Cover CPU Socket Socket Pins Removing the Dust Cover from the C...

Страница 28: ...nd Notch C on the CPU with the corresponding notches on the carrier Once they are aligned carefully insert the CPU into the carrier until you hear a click Once the CPU is properly mounted onto the car...

Страница 29: ...grease as needed Skip this step if you have a new heatsink because the necessary thermal grease is pre applied in the factory 2 Holding the processor package assembly at the center edge turn it upside...

Страница 30: ...through the corresponding mounting holes on the socket The PHM will only fit one way If it does not fit correctly remove it and try again 3 Using a T30 size star driver bit tighten four screws into th...

Страница 31: ...ting with screw marked 4 in the sequence of 4 3 2 1 2 After all four screws are removed wiggle the PHM gently and pull up to remove it from the socket Note To properly remove the processor heatsink mo...

Страница 32: ...first DIMM module of the channel and the black slot the second module of the channel When installing memory modules be sure to populate the blue memory slots first and then populate the black slots G...

Страница 33: ...l DRAM Density 1DPC 1 DIMM Per Channel 1DPC 1 DIMM Per Channel 2DPC 2 DIMM Per Channel 4Gb 8Gb 1 2 V 1 2 V 1 2 V RDIMM SRx4 4GB 8GB 2666 2666 2666 RDIMM SRx8 8GB 16GB 2666 2666 2666 RDIMM DRx8 8GB 16G...

Страница 34: ...nel SPC and DIMMs Per Chan nel DPC 1 Slot Per Channel 2 Slots Per Channel DRAM Density 1DPC 1 DIMM Per Channel 1DPC 1 DIMM Per Channel 2DPC 2 DIMM Per Channel 4Gb 8Gb 16Gb 1 2 V 1 2 V 1 2 V RDIMM SRx4...

Страница 35: ...RDIMM Raw Cards A B 2Rx4 C 1Rx4 D 1Rx8 E 2Rx8 3DS RDIMM Raw Cards A B 4Rx4 non 3DS LRDIMM Raw Cards D E 4Rx4 3DS LRDIMM Raw Cards A B 8Rx4 General DIMM Mixing Guidelines DIMM Mixing Rules All DIMMs m...

Страница 36: ...s CPU1 P1 DIMMA1 P1 DIMMD1 CPU2 P2 DIMMA1 P2 DIMMD1 2 CPUs 6 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 CPU2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 2 CPUs 8 DIMMs CPU1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMME1 CPU...

Страница 37: ...6GB 288GB A1 A2 B1 B2 C1 C2 D1 D2 448GB 384GB A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 560GB 480GB A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 672GB 576GB Dual Rank Memory Rank Sparing 16GB DIMM Memory Population Total...

Страница 38: ...M 3DS LRDIMM Refer to Validation Matrix DDR4 DIMMs validated with DCPMM below DRAM2 RDIMM DRAM3 RDIMM 3DS RDIMM LRDIMM Note DDR4 single rank x8 is not available for DCPMM Memory Mode or App Direct Mod...

Страница 39: ...Validation Matrix DDR4 DIMMs Validated w DCPMM DIMM Type Ranks Per DIMM Data Width Stack DIMM Capacity GB DRAM Density 4Gb 8Gb RDIMM 1Rx4 8GB 16GB 2Rx8 8GB 16GB 2Rx4 16GB 32GB LRDIMM 4Rx4 N A 64GB LRD...

Страница 40: ...ules of the same type and speed on the motherboard Push the release tabs outwards on both ends of the DIMM slot to unlock it 1 Align the key of the DIMM module with the receptive point on the memory s...

Страница 41: ...DIMMC1 P1 DIMMC2 SIOM CPU1 PCI E 3 0 X16 CPU1 PCI E 3 0 X4 S SATA0 5 TPM PORT80 CPU1 SLOT1 PCI E 3 0 X16 COM1 IPMI_LAN CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW VGA CPU2 SLOT2 PCI E 3 0 X16 JSD1 SATA...

Страница 42: ...PB1 JPG1 VGA Port A VGA port is located on the I O back panel Use this port to connect to a compatible VGA display 2 3 1 VGA Port 2 UID Switch 3 UID LED 1 Unit Identifier Switch UID LED Indicator A Un...

Страница 43: ...2 DIMMB2 P1 DIMMF2 P1 DIMMF1 P1 DIMMC1 P1 DIMMC2 SIOM CPU1 PCI E 3 0 X16 CPU1 PCI E 3 0 X4 S SATA0 5 TPM PORT80 CPU1 SLOT1 PCI E 3 0 X16 COM1 IPMI_LAN CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW VGA CPU...

Страница 44: ...IMMD2 P2 DIMMC2 P2 DIMMC1 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2 DIMMB2 P1 DIMMF2 P1 DIMMF1 P1 DIMMC1 P1 DIMMC2 SIOM CPU1 PCI E 3 0 X16 CPU1 PCI E 3 0 X4 S SATA0 5 TPM PORT80 CPU1 SLOT1 PCI E 3 0 X16 COM1 I...

Страница 45: ...C1 P1 DIMMC2 SIOM CPU1 PCI E 3 0 X16 CPU1 PCI E 3 0 X4 S SATA0 5 TPM PORT80 CPU1 SLOT1 PCI E 3 0 X16 COM1 IPMI_LAN CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW VGA CPU2 SLOT2 PCI E 3 0 X16 JSD1 SATA DOM...

Страница 46: ...80 CPU1 SLOT1 PCI E 3 0 X16 COM1 IPMI_LAN CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW VGA CPU2 SLOT2 PCI E 3 0 X16 JSD1 SATA DOM POWER CPU1 P1 DIMMD1 P1 DIMMD2 P1 DIMME1 P1 DIMME2 P1 DIMMA1 P1 DIMMA2 P1...

Страница 47: ...1 I SATA6 JTAG1 JCPLD1 JRK1 BT1 JBT1 JF1 JF2 JNVI2C1 JTPM1 JSD1 CPU1 PCI E 3 0 X4 CPU2 PCI E 3 0 X24 I SATA0 5 P2 DIMMF2 P2 DIMMF1 P2 DIMMD1 P2 DIMME1 P2 DIMME2 P2 DIMMD2 P2 DIMMC2 P2 DIMMC1 P2 DIMMA1...

Страница 48: ...N CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW VGA CPU2 SLOT2 PCI E 3 0 X16 JSD1 SATA DOM POWER CPU1 P1 DIMMD1 P1 DIMMD2 P1 DIMME1 P1 DIMME2 P1 DIMMA1 P1 DIMMA2 P1 DIMMB1 P1 DIMMB2 JVRM1 JPB1 JPG1 1 VROC...

Страница 49: ...MD1 P2 DIMME1 P2 DIMME2 P2 DIMMD2 P2 DIMMC2 P2 DIMMC1 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2 DIMMB2 P1 DIMMF2 P1 DIMMF1 P1 DIMMC1 P1 DIMMC2 SIOM CPU1 PCI E 3 0 X16 CPU1 PCI E 3 0 X4 S SATA0 5 TPM PORT80 CPU...

Страница 50: ...BAR CODE BIOS LICENSE IPMI CODE 1 X11DPT B REV 1 02 SXB1 SXB2 FAN3 FAN4 BMC_HB_LED1 UID_LED1 HDD_LED1 JPME1 SXB3_1 JSIOM1 SXB4 JSDCARD1 I SATA6 JTAG1 JCPLD1 JRK1 BT1 JBT1 JF1 JF2 JNVI2C1 JTPM1 JSD1 C...

Страница 51: ...ns Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clea...

Страница 52: ...ATA0 5 TPM PORT80 CPU1 SLOT1 PCI E 3 0 X16 COM1 IPMI_LAN CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW VGA CPU2 SLOT2 PCI E 3 0 X16 JSD1 SATA DOM POWER CPU1 P1 DIMMD1 P1 DIMMD2 P1 DIMME1 P1 DIMME2 P1 DIMM...

Страница 53: ...0 CPU1 SLOT1 PCI E 3 0 X16 COM1 IPMI_LAN CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW VGA CPU2 SLOT2 PCI E 3 0 X16 JSD1 SATA DOM POWER CPU1 P1 DIMMD1 P1 DIMMD2 P1 DIMME1 P1 DIMME2 P1 DIMMA1 P1 DIMMA2 P1...

Страница 54: ...MMB1 P2 DIMMB2 P1 DIMMF2 P1 DIMMF1 P1 DIMMC1 P1 DIMMC2 SIOM CPU1 PCI E 3 0 X16 CPU1 PCI E 3 0 X4 S SATA0 5 TPM PORT80 CPU1 SLOT1 PCI E 3 0 X16 COM1 IPMI_LAN CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW V...

Страница 55: ...MMB2 P1 DIMMF2 P1 DIMMF1 P1 DIMMC1 P1 DIMMC2 SIOM CPU1 PCI E 3 0 X16 CPU1 PCI E 3 0 X4 S SATA0 5 TPM PORT80 CPU1 SLOT1 PCI E 3 0 X16 COM1 IPMI_LAN CPU2 PCH USB0 1 3 0 BIOS FLASH BMC UID SW VGA CPU2 SL...

Страница 56: ...BIOS FLASH BMC UID SW VGA CPU2 SLOT2 PCI E 3 0 X16 JSD1 SATA DOM POWER CPU1 P1 DIMMD1 P1 DIMMD2 P1 DIMME1 P1 DIMME2 P1 DIMMA1 P1 DIMMA2 P1 DIMMB1 P1 DIMMB2 JVRM1 JPB1 JPG1 2 2 10 PCIe 3 0 Slots 1 The...

Страница 57: ...JF1 JF2 JNVI2C1 JTPM1 JSD1 CPU1 PCI E 3 0 X4 CPU2 PCI E 3 0 X24 I SATA0 5 P2 DIMMF2 P2 DIMMF1 P2 DIMMD1 P2 DIMME1 P2 DIMME2 P2 DIMMD2 P2 DIMMC2 P2 DIMMC1 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2 DIMMB2 P1 DI...

Страница 58: ...4 Disconnect all cables from the motherboard including those for the keyboard and mouse 5 Remove all add on cards 6 Install a CPU a heatsink and connect the internal speaker and the power LED to the...

Страница 59: ...e power cord and contacting both pads on the CMOS Clear Jumper JBT1 Refer to chapter 2 2 Remove all components from the motherboard especially the DIMM modules Make sure that system power is on and th...

Страница 60: ...r website at http www supermicro com for memory and CPU support and updates 3 HDD support Make sure that all hard disk drives HDDs work properly Replace the bad HDDs with good ones 4 System cooling Ch...

Страница 61: ...necessary remove a component in question from the chassis and test it in isolation to make sure that it works properly Replace a bad component with a good one 5 Check and change one component at a tim...

Страница 62: ...s in this chapter or see the FAQs on our website before contacting Technical Support 2 BIOS upgrades can be downloaded from our website Note Not all BIOS can be flashed depending on the modifications...

Страница 63: ...is not in control such as during memory count the first screen that appears when the system is turned on the momentary on off switch must be held for more than four seconds to shut down the system Th...

Страница 64: ...ame 4 The FLASH NSH script will compare the Flash Descriptor Table FDT code in the new BIOS with the existing one in the motherboard a If a different FDT is found A new file STARTUP NSH will be create...

Страница 65: ...aged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous wa...

Страница 66: ...nently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is complete For...

Страница 67: ...s purpose Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be co...

Страница 68: ...new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YYYY format The time is entered in HH MM SS format Note The time is in th...

Страница 69: ...FI BIOS 69 Memory Information Total Memory This feature displays the total size of memory available in the system Memory Speed This feature displays the default speed of the memory modules installed i...

Страница 70: ...reen between displaying POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The options are...

Страница 71: ...rt Select Enabled to install Windows 7 and the XHCI drivers for USB keyboard mouse support After you ve installed the Windows 7 and XHCI drivers be sure to set this feature to Disabled default The opt...

Страница 72: ...lowing CPU information will be displayed Processor BSP Revision Processor Socket Processor ID Processor Frequency Processor Max Ratio Processor Min Ratio Microcode Revision L1 Cache RAM L2 Cache RAM L...

Страница 73: ...e settings are Enable and Disable PPIN Control Select Unlock Enable to use the Protected Processor Inventory Number PPIN in the system The options are Unlock Enable and Lock Disable Hardware Prefetche...

Страница 74: ...ce Tuning Available when Power Technology is set to Custom Select BIOS to allow the system BIOS to configure the Power Performance Tuning Bias setting The options are BIOS Controls EPB and OS Controls...

Страница 75: ...260Y 6240Y 4214Y Processors are Used This feature allows the user to configure up to two additional base frequency settings for the processors used in your system as shown in the display below The opt...

Страница 76: ...is set to Native Mode hardware will choose a P state setting based on the OS guidance If this feature is set to Native Mode with No Legacy Support system hardware will choose a P state setting indepe...

Страница 77: ...pported by the software of the system The options are Enable and Disable Chipset Configuration Warning Setting the wrong values in the following items may cause the system to malfunction North Bridge...

Страница 78: ...age C States when its latency is hidden by other components during a wakeup IO Directory Cache IODC Select Enable for the IODC I O Directory Cache to generate snoops instead of generating memory locku...

Страница 79: ...ature is enabled a line will transition to the S state when the line in the A state returns only snoop misses That way subsequent reads to the line will encounter it in the S state and will not have t...

Страница 80: ...isable tCCD_L will be enforced based on the memory frequency The options are Auto and Disable tRWSR Read to Write turnaround time for Same Rank Relaxation Select Enable to use the same tRWSR DDR timin...

Страница 81: ...rrectable memory errors The default setting is 512 Intel Run Sure Select Enable to use Intel Run Sure Technology which will enhance critical data protection and increase system uptime and resiliency T...

Страница 82: ...lt setting is 24 IIO Configuration EV DFX Device Function On Hide Features When this feature is set to Enable the EV_DFX Lock Bits that are located in a processor will always remain clear during elect...

Страница 83: ...t Yes to prioritize the TPL requests that will allow the hints to be sent to help facilitate and optimize the processing of certain transactions in the system memory The options are Enable and Disable...

Страница 84: ...port Non Isoch Select Enable for the Non Isoch VT d engine to pass through DMA Direct Memory Access to enhance system performance The options are Enable and Disable Intel VMD Technology This section d...

Страница 85: ...ports without shutting down the system The options are Disable and Enable Intel VMD for Volume Management Device on CPU2 VMD Configuration for PStack0 VMD Configuration for PStack1 VMD Configuration...

Страница 86: ...Device Technology support for the PCIe slot specified by the user The options are Enable and the Disable Hot Plug Capable Select Enable to enable Hot Plug support for the root ports specified by the...

Страница 87: ...d Server ME Management Engine Configuration This feature displays the following system ME configuration settings General ME Configuration Oper Operational Firmware Version Backup Firmware Version Reco...

Страница 88: ...ich will allow the system to boot using a device attached to the SATA controller The options are Disable and Enable Aggressive Link Power Management When this feature is set to Enable the SATA AHCI co...

Страница 89: ...to Enable Select Enable to unlock sSATA HDD password in the OS The options are Enable and Disable SATA RSTe Boot Select Available when Configure SATA as is set to RAID Select Enable for full int13h su...

Страница 90: ...ions are Enabled and Disabled SR IOV Support Available if the system supports Single Root Virtualization Select Enabled for Single Root IO Virtualization support The options are Enabled and Disabled M...

Страница 91: ...SAS connector Select Legacy to boot the computer using a legacy device installed on the SAS connector The options are Disabled Legacy and EFI Bus Master Enable Select Enabled for the PCI Bus Driver to...

Страница 92: ...e is disabled it will not create the IPv6 PXE boot option The options are Disabled and Enabled IPv6 HTTP Support Select Enabled to enable IPv4 HTTP boot support If this feature is disabled it will not...

Страница 93: ...ddress and the Interrupt Request address of a serial port specified by the user Change Settings This feature specifies the base I O port address and the Interrupt Request address of Serial Port 2 Sele...

Страница 94: ...8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd i...

Страница 95: ...re to enable or disable Legacy Console Redirection after BIOS POST When the option Bootloader is selected Legacy Console Redirection is disabled before booting the OS When the option Always Enable is...

Страница 96: ...mission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and...

Страница 97: ...ect the COM port to display redirection of Legacy OS and Legacy OPROM messages The options are COM1 and COM2 SOL Serial Port for Out of Band Management Windows Emergency Management Services EMS The fe...

Страница 98: ...rity Stop Bits ACPI Settings Use this feature to configure Advanced Configuration and Power Interface ACPI power management settings for your system NUMA Support Available when the OS supports this fe...

Страница 99: ...nabled in the BIOS to enhance data integrity and system security Please note that the OS will not show the security device Neither TCG EFI protocol nor INT1A interaction will be made available for use...

Страница 100: ...public keys During system boot the platform firmware uses the trusted public keys to verify a digital signature in an attempt to manage and control the security of the platform firmware used in a hos...

Страница 101: ...ge This feature cannot be enabled in the production platforms The options are Disabled and Enabled TXT Support Select Enabled to enable Intel Trusted Execution Technology TXT support to enhance system...

Страница 102: ...s you have made and exit from the system Discard Changes and Exit Select this feature to discard the changes you have made and exit from the system Delete Certification If this feature is set to Enabl...

Страница 103: ...M disk The options are Boot Service Data and Reserved Create Raw This feature allows the user to create a raw RAM disk from all available memory modules in the system When you select this submenu and...

Страница 104: ...Name Use this item to enter the name of the iSCSI Initiator which is a unique name and must be in the IQN format The following submenu will be available for configuration Add an Attempt Delete Attempt...

Страница 105: ...the BOS All DIMMs are healthy The health status of the DCPMM is displayed DIMMs This submenu allows the user to view and configure the settings of the DCPMM memory modules installed in the system Sele...

Страница 106: ...irmware Version This feature indicates the firmware version of the DCPMM module Firmware API Version This feature indicates the firmware API version of the DCPMM module Lock State This feature indicat...

Страница 107: ...d Manufacturing Date Manufacturing Location Memory Type Memory Bank Label Data Width Label b Total Width b Speed MHz Channel ID Channel Position Revision ID Form Factor Manufacturer ID Controller Revi...

Страница 108: ...olation ARS Status Overwrite DIMM Status Last Shutdown Time First Fast Refresh Viral Policy Enable Viral State Latched Last Shutdown Status Unlatched Last Shutdown Status Security Capabilities Modes S...

Страница 109: ...r threshold value for the DCPMM module to maintain normal operations Fatal Threshold This feature indicates the highest value allowed for the DCPMM module to remain functional Beyond this value the DC...

Страница 110: ...e DCPMM module specified by the user Update Select this feature to update the firmware settings Back to Main Menu Select this feature and press Enter to return to the Intel Optane DC Persistent Memory...

Страница 111: ...First Fast Fresh state for onboard DCPMM modules Enable First Fast Fresh State Select Enabled to support the first fast fresh state of DCPMM data policy Disable First Fast Fresh State Select Disable...

Страница 112: ...he Socket ID of the DCPMM module Persistent Memory Type Capacity Free Capacity Create Goal Configuration When this submenu is selected the following items will display Create Goal Configuration for Us...

Страница 113: ...Persistent Memory Configuration menu Namespaces This subsection allows the user to select a namespace to view the following information on the selected namespace Namespace ID Name Heath Status 0x0000...

Страница 114: ...ing to use the maximum memory capacity currently available as system memory capacity Select Manual to enter the system memory capacity manually The options are Remaining and Manual Units Use this feat...

Страница 115: ...the following items will display Choose Diagnostics Type Quick Diagnostics Select Enabled for the quick diagnostics test to be performed on the DCPMM module installed in the system when needed The op...

Страница 116: ...n the screen The options are Handle and UID Capacity Units This feature allows the user to view and to set the default capacity unit of the selected DCPMM to be displayed on the screen The options are...

Страница 117: ...ging during system boot The options are Enabled and Disabled Erasing Settings Erase Event Log Select No to keep the event log without erasing it upon next system bootup Select Yes Next Reset to erase...

Страница 118: ...255 The default setting is 1 METW Multiple Event Count Time Window This feature is used to determine how long in minutes should the multiple event counter wait before generating a new event log Enter...

Страница 119: ...I Status This feature indicates the status of IPMI used in your system System Event Log Enabling Disabling Options SEL Components Select Enabled to enable all system event logging upon system boot The...

Страница 120: ...it to the system manually in the field If DHCP is selected AMI BIOS will search for a DHCP Dynamic Host Configuration Protocol server attached to the network and request the next available IP address...

Страница 121: ...manually in the field If DHCP is selected AMI BIOS will search for a DHCP Dynamic Host Configuration Protocol server attached to the network and request the next available IP address for this computer...

Страница 122: ...ngth of the password should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the passw...

Страница 123: ...ons are Enabled and Disabled Key Management Vendor Keys Provision Factory Defaults Select Yes to install manufacturer default keys for system security use The options are Enabled and Disabled Restore...

Страница 124: ...y Exchange Keys Authorized Signatures This feature allows the user to enter and configure a set of values to be used as Authorized Signatures for the system These values also indicate the sizes keys n...

Страница 125: ...natures This feature allows the user to set and save the authorized signatures used for OS recovery Select Update to update your OS Recovery Signatures Select Append to append your OS Recovery Signatu...

Страница 126: ...ed Fixed Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boot Press Enter on each item sequentially to select devices When the item above Boot...

Страница 127: ...Option Use this feature to select a boot device to delete from the boot priority list Delete Boot Option Use this feature to remove an EFI boot option from the boot priority list Add New Driver Optio...

Страница 128: ...te from the boot priority list Delete Drive Option Select the target boot driver to delete from the boot priority list Hard Disk Drive BBS Priorities Boot Option 1 5 USB Key Drive BBS Priorities Boot...

Страница 129: ...r Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configuration parameters...

Страница 130: ...from the Exit menu and press Enter This enables the user to save all changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu...

Страница 131: ...micro com support manuals AMI UEFI BIOS POST Codes User s Guide When UEFI BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot pro...

Страница 132: ...site at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB...

Страница 133: ...river browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the...

Страница 134: ...red Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash driv...

Страница 135: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can...

Страница 136: ...com products nfo IPMI cfm B 5 Logging into the BMC Baseboard Management Controller Supermicro ships standard products with a unique password for the BMC user This password can be found on a label on t...

Страница 137: ...alling or configuring components These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Battery Handling Warnung Bei Einsetzen einer falschen...

Страница 138: ...evaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fab...

Страница 139: ...tos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent...

Страница 140: ...ecovering the UEFI BIOS Image A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image The recovery block contains critical BIOS codes including memory detectio...

Страница 141: ...UEFI BIOS recovery using a USB attached device follow the instructions below 1 Please use a different machine to download the BIOS package for your motherboard or your system from the product page ava...

Страница 142: ...nt to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 6 When the screen as shown above displays use the arrow keys to select the item Proceed with flash...

Страница 143: ...menu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in EFI Shell Press F4 to save the settings and exit the BIOS Setup utility 7 After the BIOS recovery process...

Страница 144: ...y that contains the BIOS package you extracted earlier from Step 1 Enter flash nsh BIOSname at the prompt to start the BIOS update process Note Do not interrupt this process until the BIOS flashing is...

Страница 145: ...cro For the lat est updates please contact us or refer to our website at https www supermicro com Note 2 Depending on the version of driver utility package it may or may not have exactly the same as t...

Страница 146: ...at can be configured for VMD support on the screen 8 From the available PCI slots displayed on the screen select a PCI slot you want to use for a VMD device by highlighting it 9 Select the option Enab...

Страница 147: ...rollers has become available Note 1 The license and header on the motherboard for Intel VROC hardware key are required Also be sure the version of Intel Rapid Storage Technology enterprise Intel RSTe...

Страница 148: ...16 PCIe Intel VMD x16 PCIe Intel VMD x16 PCIe NVMe Device NVMe Device NVMe Device NVMe Device Processor Intel VMD x16 PCIe Intel VMD x16 PCIe Intel VMD x16 PCIe NVMe Device NVMe Device NVMe Device NVM...

Страница 149: ...ill appear Please carefully follow the instructions listed in this section to configure RAID settings for your devices as desired To Create a RAID Volume Use the arrow keys to select Create RAID Volum...

Страница 150: ...above displays enter a unique name for the RAID volume To Enter a Name for the RAID Volume From the Create RAID Volume submenu as shown on the previous screen use the arrow keys to select Name and pr...

Страница 151: ...es connected to the system Note 2 For RAID0 RAID1 RAID5 RAID10 the minimum number of NVMe devices required is two two three four respectively Note 3 Use Intel VROC Standard hardware key to support RAI...

Страница 152: ...ID spanned over VMD Controllers and press Enter The following screen will display Note For a bootable RAID volume do not cross VMD domains Enter a desired setting for your RAID volume in the pop up me...

Страница 153: ...ID Volumes From the Create RAID Volume submenu use the arrow keys to highlight Select Disk and press Enter The following screen will display The options are not selected and X selected Set the feature...

Страница 154: ...Strip Size and press Enter The following screen will display Note For RAID5 the options are 4KB 8KB 16KB 32KB 64KB and 128KB For RAID10 the options are 4KB 8KB 16KB 32KB and 64KB From the pop up menu...

Страница 155: ...Capacity GB for the RAID Volume From the Create RAID Volume submenu use the arrow keys to select Capacity GB and press Enter The following screen will display Enter the desired RAID capacity in GB in...

Страница 156: ...mes To finalize your RAID volume configuration select Create Volume from the Create RAID Volume submenu as shown on the screen below After selecting Create Volume press Enter The following screen will...

Страница 157: ...lume information use the arrow keys to select the desired RAID volume as shown below To Display RAID VOLUME Information When the screen above appears press Enter The RAID VOLUME INFO menu will appear...

Страница 158: ...RAID VOLUME INFO menu use the arrow keys to select Delete and press Enter to delete the RAID volume you have selected The following screen will appear to confirm if you want to delete the RAID Volume...

Страница 159: ...7 select the desired NVMe device from the list of RAID Member Disks and press Enter as shown below Select Reset to Non RAID from the screen below and press Enter to remove RAID data from the selected...

Страница 160: ...When the following screen displays select a non RAID physical disk to turn on the disk locator LED to locate a selected device You can also select a RAID member disk to locate the selected device When...

Страница 161: ...ection to access the All Intel VMD Controllers menu When the following screen appears select a desired NVMe device from the list of Non RAID Physical Disks After a NVMe device is selected press Enter...

Страница 162: ...want the selected device to be used as a spare device The options are Yes and No Note A spare disk is used for automatic RAID volume rebuilds when status of failed missing or at risk is detected on th...

Страница 163: ...n the E 1 section to access the All Intel VMD Controllers menu When the following screen appears select a desired NVMe device from the list of Non RAID Physical Disks for use as a journaling drive Aft...

Страница 164: ...volume The use of journaling drive that contains partial parity logging PPL can reduce the potential data loss Refer to the following illustration for the use of journaling drive Disk1 Journaling Dri...

Страница 165: ...a parity based RAID Press Enter and the following screen will appear Step 2 Use the arrow keys to select RWH Policy RWH is a scenario related to a power drive failure crash Step 1 Refer to the instruc...

Страница 166: ...he result of XOR calculation of old data and old parity PPL is a feature available for RAID5 volumes While a power drive failure crash occurring PPL information helps rebuild the RAID volume and re du...

Страница 167: ...feature RWH Policy to Journaling Drive Press Enter and the RWH JD feature will become available as shown below RWH JD Use the arrow keys to select RWH JD Press Enter and the following screen will appe...

Страница 168: ...ct use the arrow keys to select Change RWH settings and press Enter Your computer will return to the main screen of All Intel VMD Controllers as shown below Step 4 Use the arrow keys and press Enter t...

Страница 169: ...instructions on how to enable the secure boot features The F 4 section states Key Management settings F 1 Boot mode select Feature Press Del during system boot to enter the BIOS Setup utility Navigate...

Страница 170: ...ard and Custom Select Standard to load manufacturer s default secure variables Select Custom to change the image execution policy and to manage secure boot keys CSM Support Select Enabled to support t...

Страница 171: ...have the secure boot support be sure to follow the steps below Step 1 Step 4 Step 1 Set Secure Boot Mode to Standard Press Yes to install factory default keys as needed Note The Key Management menu w...

Страница 172: ...settings and exit the BIOS Setup utility Step 3 Press Del during system boot to enter the BIOS Setup utility Navigate to the Security tab and enter the Secure Boot menu Set CSM Support to Disabled Fo...

Страница 173: ...rver are allowed Step 4 Press Del during system boot to enter the BIOS Setup utility Navigate to the Security tab and enter the Secure Boot menu Set Secure Boot to Enabled For the changes to take effe...

Страница 174: ...Secure Boot Mode is set to Custom allows the secure boot keys to be installed via the external device and be involved in the secure boot process Provision Factory Defaults This feature is to provision...

Страница 175: ...ult secure boot keys and key variables Also it will reset the system to the User mode The options are Yes and No Reset To Setup Mode available when the System Mode is in User mode Select and press Yes...

Страница 176: ...eature to export NVRAM content of secure boot variables to files in a root folder on a file system device Enroll Efi Image This feature is to enroll SHA256 hash of the binary into the Authorized Signa...

Страница 177: ...ble when the system is not in Device Guard Ready Select and press Yes to remove Microsoft UEFI CA certificate from the DB The options are Yes and No Restore DB defaults Select and press Yes to restore...

Страница 178: ...port Update and Delete Select Details to display detailed information of PK Select Export to save the current PKs to a FAT formatted USB flash drive Select Update to load the factory defaults or load...

Страница 179: ...9 Note Refer to the right panel of the screen for the file formats accepted Export Use the arrow keys to select Export It is to save the current PKs to a FAT for matted USB flash drive Press Enter and...

Страница 180: ...er X11DPT B User s Manual 180 Press Enter and the following screen will appear Update Use the arrow keys to select Update It is to load the factory defaults or load PKs from a file on the external dev...

Страница 181: ...ndix F Secure Boot Settings 181 To load the factory defaults navigate to Yes and press Enter The following screen will appear To load PKs from a file on the external device navigate to No and press En...

Страница 182: ...Super X11DPT B User s Manual 182 When the following screen appears select the USB flash drive that contains the desired file...

Страница 183: ...ndix F Secure Boot Settings 183 Delete Use the arrow keys to select Delete and press Enter to clear the current PKs and reset the system to the Setup mode Press Enter and the following screen will app...

Страница 184: ...ed information of KEKs Select Export to save the current KEKs to a FAT formatted USB flash drive Select Update to load the factory defaults or load KEKs from a file on the external device Select Appen...

Страница 185: ...en will appear To load the factory defaults navigate to Yes and press Enter The following screen will appear To load KEKs from a file on the external device navigate to No and press Enter Refer to pag...

Страница 186: ...er s Manual 186 Delete Use the arrow keys to select Delete and press Enter Navigate to Yes and press Enter to clear the current KEKs Navigate to No and press Enter to delete only one certificate from...

Страница 187: ...Export to save the cur rent DB to a FAT formatted USB flash drive Select Update to load the factory defaults or load DB from a file on the external device Select Append to add variables to the exist i...

Страница 188: ...elect Export to save the current DBX to a FAT formatted USB flash drive Select Update to load the factory defaults or load DBX from a file on the external device Select Append to add variables to the...

Страница 189: ...rt to save the cur rent DBT to a FAT formatted USB flash drive Select Update to load the factory defaults or load DBT from a file on the external device Select Append to add variables to the existing...

Страница 190: ...o save the current DBR to a FAT formatted USB flash drive Select Update to load the factory defaults or load DBR from a file on the external device Select Append to add variables to the exist ing DBR...

Страница 191: ...oup of storage devices or an intermediate device attached to storage devices The iSCSI initiator and iSCSI target must connect to an IP network To have iSCSI settings available refer to instructions s...

Страница 192: ...tionally these features will become unavailable except Onboard LAN1 Option ROM Onboard LAN1 Option ROM Use the arrow keys to select Onboard LAN1 Option ROM and press Enter The options are Disabled Leg...

Страница 193: ...select iSCSI Configuration and press Enter to access the menu items Ipv4 PXE Support Ipv6 PXE Support To enable Ipv4 Ipv6 PXE boot support use the arrow keys to select and set Ipv4 PXE Support Ipv6 PX...

Страница 194: ...User s Manual 194 G 2 Configuring iSCSI Settings iSCSI Initiator Name Use this feature to enter the unique initiator name in iSCSI qualified name IQN format Add an Attempt Use the arrow keys to select...

Страница 195: ...e This feature displays the iSCSI attempt name Press Enter and the following screen will appear Press Enter and the following screen will appear Use the arrow keys to select the desired media access c...

Страница 196: ...IO is a feature that allows the system to route I O through the available paths if the active path fails be sure to have more than one physical path connected to the system Internet Protocol Use this...

Страница 197: ...o enter the number of logon sessions allowed for the iSCSI initiator to restart with the iSCSI target if the first logon connection fails Connection Establishing Timeout Use this feature to set the lo...

Страница 198: ...value is derived from the last three bytes of the OUI format ISID Also only the last three bytes of the ISID are configurable OUI format ISID This feature displays the default ISID in OUI format The...

Страница 199: ...ter the desired iSCSI initiator IP address Enable DHCP Use this feature to disable enable dynamic host configuration protocol DHCP server service for the iSCSI initiator The options are Disabled and E...

Страница 200: ...r Subnet Mask available when Enable DHCP is set to Disabled Use this feature to enter the desired iSCSI initiator subnet mask Gateway available when Enable DHCP is set to Disabled Use this feature to...

Страница 201: ...DHCP server service for the iSCSI target The options are Disabled and Enabled Note 1 Set the feature Get target info via DHCP to Disabled if you would like to specify the iSCSI target name IP address...

Страница 202: ...B User s Manual 202 Target Address Use this feature to enter the desired iSCSI target IP address Target Port This feature displays the iSCSI target port Boot LUN Use this feature to enter the LUN ID...

Страница 203: ...o set the CHAP type The options are One way and Mutual Note Challenge handshake authentication protocol CHAP is a protocol used to verify the identity of the peer of a connection Note 1 If one way uni...

Страница 204: ...hentication Type is set to CHAP Use this feature to enter the CHAP name authenticated by the iSCSI target CHAP Secret available when Authentication Type is set to CHAP Use this feature to enter the CH...

Страница 205: ...figuring iSCSI Settings 205 CHAP Status This feature displays the CHAP status Reverse CHAP Name available when CHAP Type is set to Mutual Use this feature to enter the CHAP name authenticated by the i...

Страница 206: ...ret available when CHAP Type is set to Mutual Use this feature to enter the CHAP secret 12 16 characters authenticated by the iSCSI initiator Reverse CHAP Status available when CHAP Type is set to Mut...

Страница 207: ...se the arrow keys to select Save Changes and press Enter to save settings shown on the screen Note For the changes to take effect save settings and restart the system Back to Previous Page Use the arr...

Страница 208: ...B User s Manual 208 The user will be returned to the main screen of iSCSI Configuration as shown below Delete Attempts Use the arrow keys to select Delete Attempts Press Enter and the following screen...

Страница 209: ...onfiguring iSCSI Settings 209 Attempt 1 Use the feature to disable enable Attempt 1 The options are Disabled and Enabled Attempt 2 Use the feature to disable enable Attempt 2 The options are Disabled...

Страница 210: ...anual 210 Commit Changes and Exit Press Enter to save changes and return to the main screen of iSCSI Configuration Discard Changes and Exit Press Enter to return to the main screen of iSCSI Configurat...

Страница 211: ...Appendix G Configuring iSCSI Settings 211 Change Attempt Order Use the arrow keys to select Change Attempt Order Press Enter and the following screen will appear...

Страница 212: ...Use arrow keys to select the desired Attempt then keys to move up down the selected Attempt For instance move up the selected Attempt by using key Move down the selected Attempt by using key Commit C...

Страница 213: ...Appendix G Configuring iSCSI Settings 213 Discard Changes and Exit Press Enter to return to the main screen of iSCSI Configuration without any change...

Страница 214: ...tel LAN devices via the BIOS Setup utility supported by the Unified Extensible Firmware Interface UEFI driver H 1 Network Interface Card NIC Settings Press Del during system boot to enter the BIOS Set...

Страница 215: ...N device s will become available for configuration as shown below Note If Onboard LAN1 Option ROM is set to EFI all features for onboard LAN op tion ROM will be set to EFI by the EFI driver Additional...

Страница 216: ...User s Manual 216 Use the arrow keys to select the desired onboard LAN device as shown below Press Enter and the following screen will appear It displays the detailed information for the selected onbo...

Страница 217: ...ng Network Interface Card NIC Settings 217 Blink LEDs This feature allows the user to set the LED blink duration in seconds The valid range is 0 15 seconds NIC Configuration Use the arrow keys to sele...

Страница 218: ...nd the following screen will appear Wake on LAN Use the arrow keys to select Wake On LAN and press Enter The following screen will appear The options are Disabled and Enabled Set this feature to suppo...

Отзывы: