Страница 2: ...ING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of...

Страница 3: ...http www supermicro com products for processor and memory support updates This product is intended to be installed and serviced by professional technicians Manual Organization Chapter 1 describes the...

Страница 4: ...ymbols for proper installation and to prevent damage done to the components or injury to yourself Important Important information given to ensure proper system installa tion or to relay safety precaut...

Страница 5: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...

Страница 6: ...5 ACPI Features 1 11 1 6 Power Supply 1 11 Chapter 2 Installation 2 1 Standardized Warning Statements 2 1 Battery Handling 2 1 Product Disposal 2 3 2 2 Static Sensitive Devices 2 4 Precautions 2 4 Unp...

Страница 7: ...24 CMOS Clear 2 25 VGA Enable 2 26 Watch Dog 2 26 Manufacturing Mode 2 27 BIOS Recovery Enable 2 27 SMB I2 C Bus to PCI Slots 2 28 BMC Enable Disable 2 28 I2 C Bus for VRM 2 29 Power Force On Enable...

Страница 8: ...4 33 4 8 Save Exit 4 35 Appendix A BIOS Error Beep Codes A 1 BIOS Error Beep Codes A 1 Appendix B Software Installation Instructions B 1 Installing Drivers B 1 B 2 Installing SuperDoctor 5 B 2 Appendi...

Страница 9: ...icro boards are designed with the utmost attention to detail to provide you with the highest standards in quality and performance Please check that the following items have all been included with your...

Страница 10: ...phics shown in this manual were based upon the latest PCB Revision available at the time of publishing of the manual The moth erboard you ve received may or may not look exactly the same as the graphi...

Страница 11: ...re for testing only DESIGNED IN USA 1 00 REV X10SRD F CPU 1 1 J3 SP1 JSTBY1 JPCIE1 JTPM1 SW1 S SATA SAS0 S SATA SAS1 I SATA5 I SATA4 JPCIE2 BT1 J5 JPG1 JPB1 JI2C2 JI2C1 JPME2 JPF1 JPF2 JBR1 JWD1 JVRM1...

Страница 12: ...S SGPIO2 JSD1 KVM IPMI_LAN FAN1 USB0 1 P1 DIMMD1 P1 DIMMC1 P1 DIMMB1 UID P1 DIMMA1 CPU1 SLOT1 PCI E 3 0 X8 CPU1 MICRO LP PCI E 3 0 X8 USB1 3 0 JUSB2 X10SRD F Quick Reference not drawn to scale USB0 1...

Страница 13: ...IPMI_LAN IPMI Dedicated LAN Port I SATA4 I SATA5 SATA 3 0 Ports supported by Intel PCH J5 HDD BP Selection JIPMB1 System Management Bus Header for the IPMI Slot JPCIE1 MicroLP PCI E 3 0 X8 Slot JPCIE2...

Страница 14: ...ork Connections One 1 dedicated RJ 45 I O Panel connector with Link and Activity LEDs for IPMI I O Devices SATA Connections SATA 3 0 Ports Two 2 SATA ports on Back Panel Two 2 SATA ports onboard SATA...

Страница 15: ...pset Tachometer Monitoring CPU Thermal Trip support Thermal Monitor 2 TM2 support System Management PECI Platform Environment Configuration Interface 2 0 support System resource alert via SuperDoctor...

Страница 16: ...or the actual specifications of each motherboard X10SRD F Motherboard Block Diagram LPC JPCIE1 PCIE 3 0 x16 DDR3 DIMM B1 DDR3 DIMM A1 DMI USB PROCESSOR QPI1 QPI0 PCI E x1 PCH DMI HEADER Vertical USB C...

Страница 17: ...2 Express chipset supports high speed Direct Media Interface DMI for chip to chip true isochronous communication providing up to 5 Gb s of software transparent data transfer rate on each read write di...

Страница 18: ...given or an error message is sent to the screen The user can adjust the voltage thresholds to define the sensitivity of the voltage monitor Fan Status Monitor with Firmware Control PC health monitorin...

Страница 19: ...ected power management ACPI also provides a generic system event mechanism for Plug and Play and an operating system independent interface for configuration control ACPI leverages the Plug and Play BI...

Страница 20: ...1 12 X10SRD F Motherboard User s Manual Notes...

Страница 21: ...omponents Read this section in its entirety before installing or configuring components in the Supermicro chassis Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefah...

Страница 22: ...xplosi n si la bater a se reemplaza de manera incorrecta Re emplazar la bater a exclusivamente con el mismo tipo o el equivalente recomen dado por el fabricante Desechar las bater as gastadas seg n la...

Страница 23: ...dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y regla mentos nacionales Attention L...

Страница 24: ...dges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their anti...

Страница 25: ...ded because they ground the motherboard to the chassis Make sure that the metal standoffs click in or are screwed in tightly Then use a screwdriver to secure the motherboard onto the motherboard tray...

Страница 26: ...the mounting holes on the motherboard tray 3 Install the motherboard carefully to avoid damaging motherboard components 4 Insert a Pan head 6 screw into a mounting hole on the motherboard and its matc...

Страница 27: ...iving a server board without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise contact your retailer immediately Refer to t...

Страница 28: ...ngs are provided for illustra tion purposes only OPEN1st WARNING Press down on Load Lever Open 1st OPEN1st WARNING 1 2 OPEN1st IMPORTANT 1 Before opening the LGA2011 socket remove the black IMPORTANT...

Страница 29: ...ts locking position 4 With the Close 1st lever fully retracted gently push down on the Open 1st lever to open the load plate Lift the load plate to open it completely OPEN1st WARNING OPEN1st WARNING 1...

Страница 30: ...the CPU inside the socket in one direc tion Make sure that it is properly inserted into the CPU socket before closing the load plate If it doesn t close properly do not force it as it may damage your...

Страница 31: ...e CPU to make sure that the CPU is properly installed 5 To close and lock the socket close the load plate with the CPU Lock the Close 1st lever first then lock the Open 1st lever second Use your thumb...

Страница 32: ...has already been applied 2 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard s and the Heatsink Bracket under neath 3 Screw in two diagona...

Страница 33: ...from the motherboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the CPU is...

Страница 34: ...System Memory CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage Memory Support The X10SRD F supports up to 512GB ECC 3DS LRDIMM 256GB ECC LRDIMM an...

Страница 35: ...nd Removing DIMMs 1 Position the DIMM module s bottom key so that it aligns with the receptive point on the slot 4 When the module is properly inserted the Lock Release tabs will automatically secure...

Страница 36: ...all DIMMs will run at the speed of the slowest DIMM The motherboard will support one DIMM module or three DIMM modules installed For best memory performance install DIMM modules in pairs Recommended...

Страница 37: ...D2 LED1 JUIDB1 S SGPIO1 S SGPIO2 JSD1 KVM IPMI_LAN FAN1 USB0 1 P1 DIMMD1 P1 DIMMC1 P1 DIMMB1 UID P1 DIMMA1 CPU1 SLOT1 PCI E 3 0 X8 CPU1 MICRO LP PCI E 3 0 X8 USB1 3 0 JUSB2 I O Port Location 2 6 Conne...

Страница 38: ...ype cables Power Button LED A Power Button SW1 and LED is lo cated right next to the IPMI port Push this button to turn on the motherboard When lit it indicates that this particular motherboard is tur...

Страница 39: ...Header This header is used to connect a Trusted Platform Module TPM that is available from a third party vendor A TPM is a security de vice that allows encryption and authentication of hard drives It...

Страница 40: ...itions for onboard power connectors Be sure to use the correct cable for each header or connector SATA DOM Power The SATA DOM Power on JSD1 is used to supply power to SATA Disk on Module DOM solid sta...

Страница 41: ...PCI E 3 0 X8 CPU1 MICRO LP PCI E 3 0 X8 USB1 3 0 JUSB2 A A S SGPIO1 B S SGPIO2 Serial_Link SGPIO Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 DATA Out 5 Load 6 Ground 7 Clock 8...

Страница 42: ...JUSB2 Internal Buzzer The Internal Buzzer located at SP1 can be used to provide audible alarms for various beep codes See the table on the right for pin defini tions Refer to the layout below for the...

Страница 43: ...LED2 LED1 JUIDB1 S SGPIO1 S SGPIO2 JSD1 KVM IPMI_LAN FAN1 USB0 1 P1 DIMMD1 P1 DIMMC1 P1 DIMMB1 UID P1 DIMMA1 CPU1 SLOT1 PCI E 3 0 X8 CPU1 MICRO LP PCI E 3 0 X8 USB1 3 0 JUSB2 A A Fan Header Fan Heade...

Страница 44: ...otherboard jumpers can be used to choose between optional settings Jumpers create shorts between two pins to change the function of the connector Pin 1 is identified with a square solder pad on the pr...

Страница 45: ...P1 DIMMA1 CPU1 SLOT1 PCI E 3 0 X8 CPU1 MICRO LP PCI E 3 0 X8 USB1 3 0 JUSB2 CMOS Clear JBT1 is used to clear CMOS Instead of pins this jumper consists of contact pads to pre vent accidental clearing...

Страница 46: ...nable JPG1 allows the user to enable the onboard VGA connector through the KVM Close Pins 1 2 to use this function The default setting is Enabled VGA Enable Disable Jumper Settings JPG1 Pin Definition...

Страница 47: ...overy A B Manufacturing Mode Close pins 2 and 3 of jumper JPME2 to bypass SPI flash security and force the system to operate in the Manufacturing Mode allowing the user to flash the system firmware fr...

Страница 48: ...SMB I2 C Bus to PCI Slots Jumpers JI2 C1 and JI2 C2 allow you to con nect the System Management Bus SMB to PCI E and PCI slots The default setting is set to Disabled See the table on the right for ju...

Страница 49: ...Jumpers JVRM1 and JVRM2 allow the BMC or the PCH to access CPU and memory VRM controllers See the table on the right for jumper settings VRM Pin Defintions Pin Definition 1 2 BMC Default 2 3 PCH A JV...

Страница 50: ...IMMC1 P1 DIMMB1 UID P1 DIMMA1 CPU1 SLOT1 PCI E 3 0 X8 CPU1 MICRO LP PCI E 3 0 X8 USB1 3 0 JUSB2 2 9 Onboard Indicators A IPMI LAN Port Back Panel Connectors LAN Link Speed LED Indicator LED Color Defi...

Страница 51: ...t ID LED LED Settings On Steady Unit ID switch is on A Unit ID LED B OVT Indicator OVT Indicator DESIGNED IN USA 1 00 REV X10SRD F CPU 1 1 J3 SP1 JSTBY1 JPCIE1 JTPM1 SW1 S SATA SAS0 S SATA SAS1 I SATA...

Страница 52: ...M1 LED2 LED1 JUIDB1 S SGPIO1 S SGPIO2 JSD1 KVM IPMI_LAN FAN1 USB0 1 P1 DIMMD1 P1 DIMMC1 P1 DIMMB1 UID P1 DIMMA1 CPU1 SLOT1 PCI E 3 0 X8 CPU1 MICRO LP PCI E 3 0 X8 USB1 3 0 JUSB2 A BMC Heartbeat LED A...

Страница 53: ...3 0 JUSB2 2 10 Serial ATA Connections A I SATA4 B I SATA5 C SAS0 D SAS1 A B SATA Connections Two SATA 3 0 connectors I SATA4 I SATA5 and two SAS 3 0 connectors SAS0 SAS1 are located on the motherboar...

Страница 54: ...2 34 X10SRD F Motherboard User s Manual Notes...

Страница 55: ...2 Make sure that there are no short circuits between the motherboard and chassis 3 Disconnect all ribbon wire cables from the motherboard including those for the keyboard and mouse Also be sure to re...

Страница 56: ...u use the memory modules of the same type and speed for all DIMMs in the system Do not use memory modules of differ ent sizes different speeds and different types on the same motherboard 3 Check for b...

Страница 57: ...be downloaded from our website at http www supermi cro com support bios Note Not all BIOS can be flashed Some cannot be flashed it depends on the boot block code of the BIOS 3 If you ve followed the i...

Страница 58: ...and the filename The BIOS ROM filename will bear the motherboard name i e X9SRD and build version as the extension For example X10SRD1 218 When completed your system will automatically reboot When th...

Страница 59: ...es motherboard Answer For the 1U passive heatsink ask for SNK P0047PS Question Why can t I recover the BIOS even when I ve followed the instructions in the user s manual for the motherboard Answer Ple...

Страница 60: ...1 2 above and continue below 2 Identify the battery s polarity The positive side should be facing up 3 Insert the battery into the battery holder and push it down until you hear a click to ensure that...

Страница 61: ...upermicro com RmaForm When you return the motherboard to the manufacturer the RMA number should be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shippi...

Страница 62: ...3 8 X10SRD F Motherboard User s Manual Notes...

Страница 63: ...ll the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area rese...

Страница 64: ...ot upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect special in...

Страница 65: ...s The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X10SRD F BIOS Versio...

Страница 66: ...s occurs revert to the default setting BOOT Feature Quiet Boot This option allows the bootup screen options to be modified between POST mes sages or the OEM logo Select Disabled to display the POST me...

Страница 67: ...the Watch Dog timer will allow the system to automatically reboot when a non recoverable error occurs that lasts for more than five minutes The options are Enabled and Disabled Power Button Function...

Страница 68: ...led and Enabled Hyper Threading ALL Set to Enabled to use the processor s Hyper Threading Technology feature The options are Enabled and Disabled Cores Enabled Set a numeric value to enable the number...

Страница 69: ...Enabled to activate the L1 Data Prefetcher based on sequential load history The options are Enable and Disable Direct Cache Access DCA Select Enabled to use Intel s DCA Direct Cache Access Technology...

Страница 70: ...mance Balanced Performance Balanced Power and Power Energy Efficient Turbo Use this feature to enable energy efficient turbo mode The options are Enable and Disable CPU P State Control EIST P States E...

Страница 71: ...are Enable and Disable Enhanced Halt State C1E Select Enabled to enable Enhanced Halt State support which will significantly reduce the CPU s power consumption by minimizing CPU s clock cycles and vo...

Страница 72: ...isable No Snoop Select Enable to support no snoop mode for each CB device The options are Disable and Enable Relaxed Ordering Select Enable to enable Relaxed Ordering support which will allow certain...

Страница 73: ...of Service require ments This feature is especially important for Virtualization Technology The options are Enable and Disable Memory Configuration Enforce POR Select Enable to enforce POR restrictio...

Страница 74: ...are Disabled and CLTT Closed Loop Thermal Throttling A7 Mode Select Enabled to support A7 Addressing Mode to improve memory perfor mance The options are Enable and Disable DIMM Information This item...

Страница 75: ...ol scrubbing Enter 0 for patrol scrubbing to be performed automatically The default setting is 24 Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors fo...

Страница 76: ...3 0 support The options are Disabled Enabled and Auto EHCI1 Select Enabled to enable EHCI Enhanced Host Controller Interface support on USB 2 0 connector 1 at least one USB 2 0 connector should be ena...

Страница 77: ...isabled SATA Port 0 Port 5 This item displays the information detected on the installed SATA drive on the particular SATA port Model number of drive and capacity Software Preserve Support Port 0 Port...

Страница 78: ...ller will put the link in a low power mode during extended periods of I O inactivity and will return the link to an active state when I O activity resumes The options are Enabled and Disabled SATA RAI...

Страница 79: ...e and Solid State Drive Server ME Management Engine Configuration This feature displays the following system ME configuration settings General ME Configuration Operational Firmware Version Recovery Fi...

Страница 80: ...SPM Support Use this item to set the Active State Power Management ASPM level for a PCI E device Select Auto for the system BIOS to automatically set the ASPM level based on the system configuration S...

Страница 81: ...the Interrupt Request address of a serial port specified by the user Change Port 1 Settings Change Port 2 Settings This feature specifies the base I O port address and the Interrupt Request address o...

Страница 82: ...n Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 3...

Страница 83: ...led and Enabled Legacy OS Redirection Resolution Use this item to select the number of rows and columns used in Console Redi rection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad...

Страница 84: ...o set the data transmission size for Console Redirection The options are 7 Bits and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even i...

Страница 85: ...and VT400 Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection after BIOS POST When set to Bootloader legacy Console Redirection is disabled before booting the...

Страница 86: ...flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data...

Страница 87: ...Error Logging Support Change this item to enable or disable runtime error logging The options are En abled and Disabled Memory Correction Error Threshold Change this item to define the system s memory...

Страница 88: ...ed MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item...

Страница 89: ...s IPMI Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI Status This item indicates the status of the IPMI firmware installed in your system System Event Log En...

Страница 90: ...Network Link Status This item displays the IPMI Network Link status The default setting is Shared LAN Update IPMI LAN Configuration This feature allows the user to decide if the BIOS should configure...

Страница 91: ...elongs to The value of each three digit number separated by dots should not exceed 255 Station MAC Address MAC addresses are 6 two digit hexadecimal numbers Base 16 0 9 A B C D E F separated by dots i...

Страница 92: ...up or upon entering the BIOS Setup utility The options are Setup and Always Administrator Password Use this feature to set the administrator password which is required to enter the BIOS setup utility...

Страница 93: ...keys set by the manufacturer The options are Yes and No Save All Secure Boot Variables This feature allows the user to decide if all secure boot variables should be saved Platform Key PK This feature...

Страница 94: ...the authorized time stamps Set New DBT Select Yes to load the DBT from the manufacturer s defaults Select No to load the DBT from a file The options are Yes and No Append DBT Select Yes to add the DBT...

Страница 95: ...ue of 65535 0xFFFF for the BIOS to wait indefinitely The default setting is 1 Boot Mode Select Use this item to select the type of device that the system is going to boot from The options are Legacy U...

Страница 96: ...e Boot Option Select the target boot device to delete Network Drive BBS Priorities Legacy Boot Order 1 This feature sets the system boot order of detected devices The options are the list of detected...

Страница 97: ...hanges and Reset When you have completed the system configuration changes select this option to leave the BIOS Setup Utility and reboot the computer so the new system con figuration parameters can tak...

Страница 98: ...ults from the Exit menu and press En ter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit...

Страница 99: ...oc curs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list corresp...

Страница 100: ...A 2 X10SRD F Motherboard User s Manual Notes...

Страница 101: ...p to the bottom one at a time After installing each item you must reboot the system before proceeding with the next item on the list Appendix B Software Installation Instructions B 1 Installing Driver...

Страница 102: ...tem voltages system power consumption fan speed and provides alerts via email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used wit...

Страница 103: ...off control to a computer system at bootup C 2 How to Recover the UEFI BIOS Image the Main BIOS Block A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image...

Страница 104: ...USB attached device follow the instruc tions below 1 Using a different machine copy the Super ROM binary image file into the disc root directory of a USB device or a writeable CD DVD Note If you canno...

Страница 105: ...want to start with BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays using the arrow key select the item Proceed with flas...

Страница 106: ...ng the message that BIOS update is completed unplug the AC power cable from the power supply to clear the CMOS and then plug the AC power cable into the power supply again to power on the system 10 Pr...

Страница 107: ...expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in su...