Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 620U TNR ...
Страница 2: ...Class A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be require...
Страница 3: ... and utilities https www supermicro com wftp Product safety info https www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support supermicro com This manual may be periodically updated without notice Please check the Supermicro website for possible updates to the manual revision level Secure Data Deletion A secure data deletion too...
Страница 4: ...cator 14 Expansion Slots and Riser Cards 15 LAN Speed Indicator 15 Top View 16 1 3 System Architecture 17 Main Components 17 System Block Diagram 18 1 4 Motherboard Layout 19 Quick Reference 20 Motherboard Block Diagram 21 Chapter 2 Server Installation 2 1 Overview 22 2 2 Unpacking the System 22 2 3 Preparing for Setup 22 Choosing a Setup Location 22 Rack Precautions 23 Server Precautions 23 Rack ...
Страница 5: ...t 40 Removing the Processor Carrier Assembly from the PHM 41 Removing the Processor from the Carrier Assembly 42 3 4 Memory 43 Memory Support 43 Guidelines Regarding Mixing DIMMs 44 DDR4 Memory Population Guidelines 45 Optane PMem 200 Series 46 PMem Notes 47 Installing Memory 48 3 5 Motherboard Battery 49 3 6 Storage Drives 50 Installing Drives 50 Checking the Temperature of an NVMe Drive 52 Hot S...
Страница 6: ...Software 5 1 Microsoft Windows OS Installation 75 5 2 Driver Installation 77 5 3 SuperDoctor 5 78 5 4 BMC 79 BMC ADMIN User Password 79 Chapter 6 Optional Components 6 1 Storage Protocols Supported 80 6 2 Power Supply Modules 80 6 3 Cable Management Arm 81 6 4 TPM Security Module 83 6 5 Intel Virtual RAID on CPU VROC 84 Requirements and Restrictions 84 Supported SSDs and Operating Sytems 84 Additi...
Страница 7: ... 4 BIOS Error Beep POST Codes 97 Additional BIOS POST Codes 97 7 5 Crash Dump Using the BMC Dashboard 98 7 6 UEFI BIOS Recovery 99 Overview 99 Recovering the UEFI BIOS Image 99 Recovering the Main BIOS Block with a USB Device 99 7 7 CMOS Clear 104 7 8 BMC Reset 104 7 9 Where to Get Replacement Components 105 7 10 Reporting an Issue 105 Technical Support Procedures 105 Returning Merchandise for Ser...
Страница 8: ...B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Website www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 ...
Страница 9: ...ors Drive Support Twelve 3 5 SATA SAS NVMe hybrid drive bays Two SuperDOM disk on modules Expansion Slots Eight PCIe 4 0 Five x8 full height 10 5 One x16 full height 10 5 One x16 low profile One internal x8 low profile I O Ports LAN ports depend on Ultra Riser option One VGA ports rear One serial port rear Two USB 3 0 ports rear System Cooling Four 8 cm heavy duty fans with Optimal Fan Speed Contr...
Страница 10: ...x16 WIO Riser Cards Several customer choices are available for other riser cards See the Expansion Slots and Riser Cards section in this chapter for details Storage Protocols The storage drive bays can support SATA SAS and NVMe in any combination To enable SAS and NVMe additional hardware is required Once the supporting hardware is installed for a selection of bays drives of any storage protocol t...
Страница 11: ...cators Each drive carrier has two LED indicators an activity indicator and a status indicator For RAID configurations using a controller the meaning of the status indicator is described in the table below For OS RAID or non RAID configurations some LED indications are not supported such as hot spare For VROC configurations refer to the VROC section in this manual Drive Carrier LED Indicators Color...
Страница 12: ... Fault detected HDD LED Indicates activity on the storage drives when flashing NIC LED Indicates network activity on LANs when flashing Power Fail LED Indicates a power supply module has failed Information LED Alerts operator to several states as noted in the table below Control Panel Figure 1 2 Control Panel Power Button Power LED Information LED UID Button LED BMC Reset HDD NIC LED NIC LED Power...
Страница 13: ... solid with Power LED blinking green Fault detected Blue and red blinking at 10 Hz Recovery mode Blue solid UID has been activated locally to locate the server in a rack environment Blue blinking at 1Hz UID has been activated using the BMC to locate the server in a rack environment Blue blinking at 2Hz BMC is resetting Blue blinking at 4Hz BMC is setting factory defaults Blue blinking at 10Hz with...
Страница 14: ...rial port VGA Video port Power Supplies USB Ports BMC LAN VGA COM UID LED BMC Reset 1 0 4 3 5 6 8 7 2 Power Supply Indicator LEDs on the power supplies indicate the status of the module Power Supply Indicator LED Color and State Power Supply Condition Solid Green Indicates that the power supply is on Blinking Green Indicates that the power supply is plugged in and turned off by the system Blinking...
Страница 15: ...ll PCIe 4 0 Ultra Riser card AOC 2UR668G4 1 2 3 x16 FH 10 5 L CPU2 x16 FH 10 5 L CPU2 x8 in x16 Internal LP CPU1 AOC 2UR68G4 i2XT AOC 2UR68G4 i4XTS AOC 2UR68G4 m2TS 1 2 3 x16 FH 10 5 L CPU2 x8 in x16 FH 10 5 L CPU2 x8 in x16 Internal LP CPU2 Right facing RSC WR 6 4 x16 low profile CPU1 Left facing RSC W2 8888G4 5 6 7 8 x8 FH 10 5 L CPU2 x8 FH 10 5 L CPU2 x8 FH 10 5 L CPU1 x8 FH 10 5 L CPU1 RSC W2 ...
Страница 16: ...ous page SuperDOM ports Disk on Module port allows for flash cards to be mounted directly on the motherboard DIMM slots Dual in line memory module DIMMs slots Processors Dual Intel Xeon Scalable Processors with heatsinks SNK P0078P System fans Four 8 cm heavy duty PWM fans FAN 0209L4 4 System Fans SATADOM Ports Dual Processors Power Supply Modules DIMM Slots ...
Страница 17: ...ocations of the system electrical components and a block diagram of the overall system Main Components Figure 1 5 Main Component Locations Storage Backplane BPN NVME4 216N S24 manual Ultra Riser Card options Motherboard X12DPU 6 Riser Card Left facing Riser Card Right facing ...
Страница 18: ...R4 DIMM Slots 16 DDR4 DIMM Slots PCI E x16 Intel Xeon Scalable Processor CPU1 Intel C621A Intel Xeon Scalable Processor CPU2 2 USB 3 0 2 rear 4 NVME CPU2 6 NVME CPU1 PCI E x8 PCI E x16 Ultra Riser Slot 40 PCI E Lanes WIO LH Riser Slot 32 PCI E Lanes DMI PCI E x24 12 SATA WIO Riser Card 2 PCI E 4 0 x8 Slots CPU1 2 PCI E 4 0 x8 Slots CPU2 2 NVME via AOC CPU2 Options of Ultra Riser Card No NIC Riser ...
Страница 19: ... P2 DIMMD2 P2 DIMMD1 P2 DIMMB2 P2_NVMe10 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2_NVMe9 BP PWR2 BP PWR3 BP PWR4 NVME7 P1 DIMMC2 P1 DIMMD2 P1 DIMMC1 P1 DIMMD1 P1 DIMMA2 P1 DIMMA1 P1 DIMMB2 P1 DIMMB1 P1 DIMMF1 P1 DIMMF2 P1 DIMME1 P1 DIMME2 P1 DIMMH1 P1 DIMMH2 P1 DIMMG1 P1 DIMMG2 JPW4 BP PWR1 JPW3 JUID NVME8 P2_NVMe8 JGPW3 JSD1 JGPW4 GPU PWR3 GPU PWR1 GPU PWR2 GPU PWR4 JCOM1 JVGA1 BMC CODE BAR CODE SATA4 SAT...
Страница 20: ... VPP 2 JGPW1 JGPW2 JGPW3 JGPW4 GPU 8 pin power connectors power connectors for GPU use JPW1 JPW2 JPW3 JPW4 Backplane 8 pin power connectors for backplane devices JUIDB UID LED BMC Reset switch JVGA2 Front accessible VGA connection header optional PSU1 PSU2 Power Supply Unit 1 Power Supply Unit 2 for system use JSD1 JSD2 SATA DOM Disk_On_Module power connectors JTPM1 Trusted Platform Module connect...
Страница 21: ...IMM 2 1 DDR4 DIMM 2 1 DDR4 DIMM DDR4 2 1 VGA UART DDR4 DIMM 2 1 64GB s PCH SATA Gen3 4 7 S SATA5 S SATA4 sSATA Gen3 0 3 JS1 JS3 sSATA Gen3 4 5 DMI USB3 0 0 1 3 4 SPI LPC eSPI TPM Header HWM USB SPI MUX LPC eSPI PE PE 5 SPI FLASH 32MB BMC SPI FLASH 32MB BIOS BMC LAN RJ45 COM1 PHY RTL8211F VGA NCSI DDR4 SPI BMC AST2600 VCCP2 7 1 PHASE X12DPU 6 VR13HC VCCP2 12v 7 1 PHASE VCCP1 VR13HC VCCP1 12v 64GB s...
Страница 22: ... be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated It will also require a grounded AC power outlet nearby Be sure to read the precautions and considerations noted in Appendix A 2 3 Preparing for Setup The box in which the system was shipped should include the rackmount hardware needed to install it into th...
Страница 23: ... the electrical and general safety precautions in Appendix A Determine the placement of each component in the rack before you install the rails Install the heaviest server components at the bottom of the rack first and then work your way up Use a regulating uninterruptible power supply UPS to protect the server from power surges and voltage spikes and to keep your system operating in case of a pow...
Страница 24: ... be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelin...
Страница 25: ... installation instructions that came with the specific rack you are using Identifying the Rails The chassis package includes two rail assemblies Each assembly consists of three sections An inner rail that secures directly to the chassis an outer rail that secures to the rack and a middle rail which extends from the outer rail These assemblies are specifically designed for the left and right side o...
Страница 26: ...etely out of the rack when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails 1 Pull the inner rail out of the outer rail until it is fully extended as illustrated below 2 Press the locking tab down to release the inner rail 3 Pull the inner rail all the way out Inner Rail Locking Tab Middle Rail Outer Rail 1 2 3 ...
Страница 27: ...er rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the quick release bracket snaps into place securing the rail to the chassis 4 Optionally you can further secure the inner rail to the chassis with screws Figure 2 3 Inner Rails Installed on the Chassis Inn...
Страница 28: ...ail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square holes on the rear of the rack Take care that the proper holes are used so the rails are level If desired use screws to secure the rear of the outer rail to the rear of the rack Note The figure above is for illustrative purposes only Always install servers ...
Страница 29: ...2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws may be used to hold the front of the chassis to the rack Figure 2 5 Installing the Server into the Rack Note Keep the ball bea...
Страница 30: ...sistance Be sure to have sufficient assistance supporting the chassis when removing it from the rack Use a lift 1 If necessary loosen the thumb screws on the front of the chassis that hold it in the rack 2 Pull the chassis forward out the front of the rack until it stops 3 Press the release latches on each of the inner rails downward simultaneously and continue to pull the chassis forward and out ...
Страница 31: ... Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing non hot swap components or when replacing a non redundant power supply 1 Use the operating system to power down the system 2 After the system has completely shut down disconnect the AC power cord ...
Страница 32: ... These two screws are optional and will not impact functionality if they are not installed 2 Press the two release buttons and slide the cover toward the rear 3 Lift the top cover up Check that all ventilation openings on the top cover and the top of the chassis are clear and unobstructed Caution Except for short periods of time do not operate the server without the cover in place The chassis cove...
Страница 33: ...that the plastic protective cover is on the CPU socket and that none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure on the land grid array gold contacts Improper installation or socket misalignment can cause serious damage to the processor or the socket and may require manufacturer repairs Thermal grease is pre ap...
Страница 34: ...g down Locate the gold triangle at the corner of the processor and the corresponding hollowed triangle on the processor carrier as shown below These triangles indicate the location of pin 1 Latch Latch Processor Reverse Side Up Carrier Top Side Up CPU Key CPU Key Latch Latch Pin 1 Processor Pin 1 Carrier 2 Turn the processor over with the gold LGA up Locate the CPU keys on the processor and the fo...
Страница 35: ...d of the processor under latch 1 on the carrier and then press the other end down until it snaps into latch 2 and is properly seated on the carrier Processor Carrier Assembly Top View Processor Carrier Assembly Underside view 3 Locate the lever on the carrier and if necessary press it down as shown below 4 Align the CPU keys on the processor A B with those on the carrier a b as shown below Lever ...
Страница 36: ...n the heatsink over with the thermal grease facing up Note the two triangle cutouts A B located at the diagonal corners of the heatsink as shown in the drawing below 2 On the processor carrier assembly find pin 1 as noted by the triangles Hold the processor carrier assembly over so that the gold LGA is facing up 3 Align clip a pin 1 on the carrier assembly with the triangular cutout A on the heats...
Страница 37: ...and Component Installation Installing the PHM into the CPU Socket 1 Remove the plastic protective cover from the CPU socket Gently squeeze the grip tabs then pull the cover off CPU Socket with Plastic Protective Cover Grip Tabs ...
Страница 38: ...fasteners a b c d on the CPU socket 3 Locate four PEEK nuts A B C D and four rotating wires 1 2 3 4 on the heatsink as shown below 4 Check that the rotating wires 1 2 3 4 are in the unlatched position as shown Heatsink A B C D Peek Nut 1 2 3 4 Rotating Wire a b c d Threaded Fastener Peek Nut Unlatched latched Rotating Wire B D Rotating Wire2 Rotating Wire 4 Rotating Wire 3 Peek Nut A C Rotating Wi...
Страница 39: ...tsink on the CPU socket making sure that each nut is properly aligned with its corresponding threaded fastener Latched State Top View 7 Press all four rotating wires outward to latch the PHM onto the CPU socket 8 With a t30 bit screwdriver tighten all PEEK nuts in the sequence of A B C and D with even pressure not greater than 12 lbf in a b c d Threaded Fastener on the CPU socket A B C D a b c d A...
Страница 40: ... CPU Socket Be sure the system is shut down and all AC power cords are unplugged 1 Use a t30 bit screwdriver to loosen the four PEEK nuts on the heatsink in the sequence of A B C and D 2 Press the four rotating wires inward to unlatch the PHM as shown below 3 Gently lift the PHM upward to remove it from the CPU socket A B C D Peek Nut ...
Страница 41: ...or Carrier Assembly from the PHM Detach the four plastic clips a b c d on the processor carrier assembly from the four corners of the heatsink A B C D as shown below and lift off the processor carrier assembly Processor Carrier Assembly Heatsink c a b d A C D B Pin 1 Pin 1 ...
Страница 42: ... the Carrier Assembly Unlock the lever from its locked position and push it upwards to disengage the processor from the carrier as shown below right Carefully remove the processor from the carrier Processor Carrier Assembly Lever Note Handle the processor with care to avoid damage ...
Страница 43: ...E IPMI CODE X12DPU 6 FAN2 NVME4 NVME5 NVME6 NVME9 NVME1 SXB3_3 SXB2 JTPM1 JNCSI1 BT1 FAN7 FAN6 FAN5 FAN4 FAN3 FAN2 T SGPIO3 JPW2 JPW1 JGPW1 JGPW2 JRK1 JLAN1 JBT1 JUIDB2 JUSB3 SXB3_1 SXB1_1 SXB1_3 PSU1 SXB3_2 SXB1_2 JS2 JS1 JS3 JWD1 JIPMB1 SP1 JSD2 LEDM1 BMC BMC FW1 PSU2 PCH LE2 BIOS1 BIOS2 BMC FW2 PW Supply2 PW Supply1 JF1 FP CTRL JL1 JF2 JNVI2C3 JF3 FAN8 NVME3 NVME10 FAN1 JNVI2C4 JVGA2 Front VGA ...
Страница 44: ...ts Mixing of non 3DS and 3DS LRDIMM is not allowed in the same channel across different channels and across different sockets Mixing of PMem modules and RDIMMs is supported Mixing DDR4 and PMem memory operating frequencies is not validated within a socket or across sockets If DIMMs of different frequencies are mixed in the same channel all DIMs will run at the highest common frequency Always popul...
Страница 45: ... B1 C1 D1 E1 F1 G1 H1 CPU2 A1 B1 C1 D1 E1 F1 G1 H1 2 CPUs 18 DIMMs CPU1 A1 A2 B1 C1 C2 D1 E1 E2 F1 G1 G2 H1 CPU2 A1 B1 C1 E1 F1 G1 2 CPUs 20 DIMMs CPU1 A1 A2 B1 C1 C2 D1 E1 E2 F1 G1 G2 H1 CPU2 A1 B1 C1 D1 E1 F1 G1 H1 2 CPUs 22 DIMMs CPU1 A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 CPU2 A1 B1 C1 E1 F1 G1 2 CPUs 24 DIMMs CPU1 A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 CPU2 A1 B1 C1 D1 E1 F1...
Страница 46: ...4 DDR4 DDR4 DDR4 DDR4 DDR4 PM DDR4 DDR4 PM DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 PM DDR4 DDR4 DDR4 DDR4 DDR4 8 DDR4 4 PMem AD MM 1 x4 DDR4 DDR4 PM DDR4 DDR4 PM PM DDR4 DDR4 PM DDR4 DDR4 2 x2 DDR4 DDR4 PM DDR4 PM DDR4 DDR4 PM DDR4 PM DDR4 DDR4 1 x4 DDR4 PM DDR4 DDR4 DDR4 PM PM DDR4 DDR4 DDR4 PM DDR4 2 x2 DDR4 PM DDR4 DDR4 PM DDR4 DDR4 PM DDR4 DDR4 PM DDR4 8 DDR4 8 PMem AD MM One x8 DDR4...
Страница 47: ...ptimized PMem to DRAM cache ratio in MM and MM AD modes For each individual population different PMem rearrangements among channels are permitted so long as the configuration does not break X12 DP Memory population rules Ensure the same DDR4 DIMM type and capacity are used for each DDR4 PMem popu lation If the system detects an unvalidated config then the system issues a BIOS warning The CLI funct...
Страница 48: ... power from the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release Tabs 2 Align the key of the DIMM with the receptive point on the memory slot and with your thumbs on both ends of the module press it straight down into the slot until the module snaps into place 3 Pr...
Страница 49: ...n the motherboard Replacing the Battery Begin by removing power from the system 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the holder 2 To insert a new battery slide one edge under the lip of the holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully D...
Страница 50: ...ives 3 6 Storage Drives The system supports twelve hot swap 3 5 hybrid storage drive bays For compatible drives see the X12DPU 6 motherboard page The drives are mounted in tool less drive carriers that simplify their removal from the chassis These carriers also help promote proper airflow Note Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For informati...
Страница 51: ...tion the drive above the carrier with the PCB side facing down and the connector end toward the rear of the carrier 3 Tilt the drive to insert it onto the two posts on the left inside of the carrier 4 Push the right side of the drive fully into the carrier and allow the two spring locking clasps to secure the drive 5 Insert the drive carrier into its bay keeping the release button on the right Whe...
Страница 52: ...o a Carrier Checking the Temperature of an NVMe Drive There are two ways to check using the BMC Dashboard Checking a Drive BMC Dashboard Server Health NVMe SSD Shows the temperatures of all NVMe drives BMC Dashboard Server Health Sensor Reading NVME_SSD Shows the single highest temperature among all the NVMe drives ...
Страница 53: ...rs support NVMe surprise hot swap For even better data security NVMe orderly hot swap is recommended NVMe drives can be ejected and replaced remotely using the BMC Dashboard Note If you are using VROC see the VROC section in this manual instead Ejecting a Drive 1 BMC Dashboard Server Health NVMe SSD 2 Select Device Group and Slot and click Eject After ejecting the drive Status LED indicator turns ...
Страница 54: ...e model Failed fans can be identified through the BMC Changing a System Fan 1 Determine which fan has failed using the BMC or if necessary open the chassis while the system is running Never run the server for long without the chassis cover 2 Push the release tab and pull the failed fan from the chassis Fans can be replaced while the system is running 3 Replace the failed fan with an identical fan ...
Страница 55: ...ure 3 11 Installing the Standard Air Shrouds Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency They do not require screws to install Installing the Standard Air Shrouds Position the air shrouds as illustrated in the figure below Shrouds ...
Страница 56: ...When illuminated indicates that the power supply is on Blinking Green When blinking indicates that the power supply is plugged in and turned off by the system Blinking Amber When blinking indicates that the power supply has a warning condition and continues to operate Solid Amber When illuminated indicates that the power supply is plugged in and is in an abnormal state The system might need servic...
Страница 57: ...0 5 L CPU2 x16 FH 10 5 L CPU2 x8 in x16 Internal LP CPU1 AOC 2UR68G4 i2XT AOC 2UR68G4 i4XTS AOC 2UR68G4 m2TS 1 2 3 x16 FH 10 5 L CPU2 x8 in x16 FH 10 5 L CPU2 x8 in x16 Internal LP CPU2 Right facing RSC WR 6 4 x16 low profile CPU1 Left facing RSC W2 8888G4 5 6 7 8 x8 FH 10 5 L CPU2 x8 FH 10 5 L CPU2 x8 FH 10 5 L CPU1 x8 FH 10 5 L CPU1 RSC W2 688G4 5 7 8 x16 FH 10 5 L CPU2 x8 in x16 FH 10 5 L CPU1 ...
Страница 58: ...stic flip lever with an arrow on it Flip open the appropriate lever to release the bracket then pull the bracket out of the chassis 3 Insert the expansion card s into the riser card slot s while aligning the rear PCI shield 4 Replace the riser card into the motherboard expansion slot while aligning the bracket into the chassis Flip the black plastic lever back in place making sure it snaps closed ...
Страница 59: ...ary remove the full height expansion card to access the low profile riser card slot pictured above 3 Insert the expansion card into the riser card slot while aligning the rear PCI shield into the chassis Add the screw to secure the PCI shield 4 Replace the full height expansion card above the low profile card if necessary then replace the chassis cover Installing the Low Profile Center Expansion C...
Страница 60: ...also offers another internal low profile card slot 3 Installation is pictured below See previous procedures for details to access the riser card and bracket View from Rear of Chassis View from Front of Chassis Internal Expansion Card Thumb Screw to Secure Bracket Figure 3 17 Bracket for Mounting an Internal Expansion Card on the Ultra Riser Card four port Ultra card shown in this example Mounting ...
Страница 61: ...sion Cards with Optional Storage Drives This server supports an option to add two storage drives in place of expansion cards Optional Cage for Two Storage Drives View from Front of Chassis View from Rear of Chassis Removing the Ultra Riser Card To remove the Ultra riser card from the motherboard remove one screw and lift carefully with two hands ...
Страница 62: ...flow through the system SAS cable routing depends on the model and position of the SAS controller card so routing is not shown here Figure 3 19 Storage Backplane BPN SAS3 LA26A N12 manual Online Cable Matrix Backplane Power Cable CBL PWEX 0923 Front Panel Control Cable CBL 0335L Optional NVMe Cable CBL KIT 620U TNR 12 12N SATA Cable CBL SAST 1241F 100 CBL SAST 1250F 100 Optional SAS Cables not sho...
Страница 63: ...nector Two proprietary main power headers are located at PSU1 and PSU2 Connect appropriate power supply units to these two headers to provide adequate power to your system Important To provide adequate power to the motherboard connect the both main power connectors and 8 pin power connectors to the power supply Failure to do so may void the manufacturer s warranty on your power supply and motherbo...
Страница 64: ...n Definition 1 Ground Black 2 12V Red 3 Tachometer 4 PWM Control SGPIO Header A Serial General Purpose Input Output header T SGPIO3 is used to communicate with the enclosure management chip on the backplane SGPIO Header Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 DATA Out 5 Load 6 Ground 7 Clock 8 NC NC No Connection Disk On Module Power Connector Two power connectors for SA...
Страница 65: ...MISO 5 SPI_PCH_CLK 6 Ground 7 SPI_PCH_MOSI 8 N A 9 JTPM1_P3V3A 10 IRQ_TPM_SPIN_N Internal Speaker Buzzer The Internal Speaker Buzzer SP1 is used to provide audible indications for various beep codes Internal Buzzer Pin Definitions Pin Definition 1 Pos Beep In 2 Neg Alarm Speaker NVMe SMBus Headers NVMe SMBus I2 C headers JNVI2 C3 4 used for PCI E SMBus clock and data connections provide hot plug s...
Страница 66: ...board may look different 4 pin BMC External I2 C Header A System Management Bus header for the BMC is located at JIPMB1 Connect a cable to this header to use the IPMB I2 C connection on your system External I2 C Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard Attach the appropriate cable...
Страница 67: ...r Button Data signal Ground Key Power On LED Control signal HDD LED Activity signal NIC1 LED Ground NIC2 LED Ground OH Fan Fail LED Ground Power Fail LED Ground Ground Ground 2 1 20 19 Power Button The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configured to function as a suspend button with a sett...
Страница 68: ...e LED 8 OH Fan Fail LED NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Controller LED connection for LAN port 1 is located on pins 11 and 12 of JF1 and the LED connection for LAN port 2 is on pins 9 and 10 Attach the NIC LED cables here to display network activity LAN1 LAN2 LED Pin Definitions JF1 Pin Definition 9 NIC2 Activity LED 10 NIC2 Link LED 11 NIC1 Activity LED 12 NIC1 Link LED HDD LED UID ...
Страница 69: ...nnection is located on pins 15 and 16 of JF1 Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Power LED NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 NMI Button Pin Definitions JF1 Pin Definition 19 Control 20 Ground ...
Страница 70: ...provided by the Ultra riser card depending on the option you purchased Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch and a UID LED indicator are located on the rear of the system When you press the UID switch both front and rear UID LED indicators are toggled on or off The UID indicators provide easy identification of a system in a rack Note the UID can also be triggered us...
Страница 71: ... can reboot the system when a software application hangs Jumping pins 1 2 will cause Watch Dog to reset the system if an application hangs Jumping pins 2 3 will generate a non maskable interrupt signal for the application that hangs Watchdog must also be enabled in BIOS The default setting is Reset Note When Watchdog is enabled the user must write their own application software to disable it Watch...
Страница 72: ...his jumper is set to Disabled both rear VGA port located at I O back panel and the optional front accessible VGA header located at JVGA2 are disabled The default setting is on pins 1 2 to enable the connection for VGA support VGA Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled ...
Страница 73: ...C is functioning normally 4 5 LED Indicators Network LAN LEDs The Ethernet ports each have two LEDs One LED indicates activity when flashing green The other may be green amber or off to indicate the speed of the connection Speeds are noted in Chapter 1 Dedicated BMC LAN LEDs A dedicated BMC LAN port is also included on the motherboard The amber LED on the right of the BMC LAN port indicates activi...
Страница 74: ... do not require external power cables Supermicro SuperDOMs are compatible with regular SATA HDDs or SATA DOMs that need external power cables NVMe Connectors Five NVMe connectors P1_NVMe1 3 4 5 6 supported by Processor 1 provide five NVMe connections In addition four NVMe connectors P2_NVMe7 8 9 10 supported by Processor 2 also provide four NVMe connections on the motherboard Use these NVMe connec...
Страница 75: ... supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive or the BMC KVM console 2 Retrieve the proper RST RSTe driver Go to the Supermicro web page for your motherboard and click on Download the Latest Drivers and Utilities select the proper driver and cop...
Страница 76: ...river browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the SATA sSATA AHCI driver indicated then choose the storage drive on which you want to install it 5 Once all devices are specified continue with the installation 6 After the Windows OS installation has c...
Страница 77: ...ISO file if preferred Another option is to go to the Supermicro website On the product page for your motherboard Download the Latest Drivers and Utilities Insert the flash drive or disk and the screenshot shown below should appear Figure 5 3 Driver Tool Installation Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the ri...
Страница 78: ...Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or the BMC SuperDoctor 5 Management Server monitors HTTP FTP and SMTP services to op...
Страница 79: ...ntation and information on BMC visit our website at www supermicro com en solutions management software bmc resources BMC ADMIN User Password For security each system is assigned a unique default BMC password for the ADMIN user This can be found on a sticker on the chassis and a sticker on the motherboard The sticker also displays the BMC MAC address Figure 5 5 BMC Password Label The sticker can b...
Страница 80: ...quired Once the supporting hardware is installed for a selection of bays drives of any storage protocol type can be inserted SATA The default configuration supports up to twelve SATA drives SAS An add on controller card and cables can support up to twelve SAS drives NVMe The motherboard supports up to ten NVMe drives A retimer card is required to add support for an additional two NVMe drives Addit...
Страница 81: ...e front of the rack for maintenance The CMA attaches to the rack mounting rails by means of four connectors They are labeled on the connectors 1 2 3 and 4 Installing the Cable Management Arm 1 Slide CMA connector 1 forward onto the two posts on the rear of the right inner rail right side when viewed from the front It snaps into place 2 Slide CMA connector 2 forward onto the two posts on the rear o...
Страница 82: ...er rail and push it forward It snaps into place 5 Route the cables through the holding brackets leaving enough slack 1 2 1 4 3 Removing the Cable Management Arm 1 Remove cables from the CMA 2 For CMA connector 4 pull the metal release tab toward the center of the rack and slide the connector toward the rear to release it 3 For CMA connectors 3 2 and 1 depress the front edge of the yellow plastic r...
Страница 83: ...d to connect a Trusted Platform Module TPM A TPM is a security device that supports encryption and authentication in hard drives It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system Details and installation procedures are at http www supermicro com manuals other TPM pdf AOM TPM 9670V AOM TPM 9671V ...
Страница 84: ...Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise Intel RSTe Driver for Windows To enable Intel VROC a hardware key must be inserted on the motherboard and the ap propriate processor s Virtual Management Devices must be enabled in the BIOS setup It is pos...
Страница 85: ...ions are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd party SSDs AOC VROCPREMOD 951606 Intel SSD only RAID 0 1 5 10 Supports Intel SSDs only AOC VROCINTMOD 956822 Additional Information Additional information is available on the product page for the Supermicro add on card a...
Страница 86: ...ns 2 Switch to Advanced Chipset Configuration North Bridge IIO Configuration Intel VMD Technology Figure 6 7 BIOS Selecting VMD Mode You can select a mode The default is Auto The VMD switch enables VMD mode for all NVMe ports despite the presence of the VROC key The Manual switch allows the user to choose devices on which to enable VMD The onboard M 2 NVMe from PCH is located in the CPU1 section T...
Страница 87: ...Optional Components Figure 6 8 BIOS Manual Mode Example your server may look different 3 Select the desired PStack to Enable or Disable the corresponding Intel VMD controller Figure 6 9 BIOS Enabling VMD for Pstack0 ...
Страница 88: ...Capability can also be Enabled or Disabled Figure 6 10 BIOS Enabling VMD Functionality per Slot 5 Repeat steps 3 and 4 for each PStack on each CPU to be enabled or disabled In this example we enabled CPU1 Slot1 Figure 6 11 and CPU2 Slot5 Figure 6 12 four U 2 form factor SSDs as well as CPU1 M 2 C 1 and CPU1 M2 C 2 two M 2 form factor SSDs Figure 6 11 BIOS Enabling CPU1 Example ...
Страница 89: ... without first deleting the associated existing RAID volume can lead to unexpected behavior This action is strongly not recommended Note The effects of physically changing or swapping a CPU on the VMD controller enablement has not yet been thoroughly tested or documented 7 Switch to Advanced Intel R Virtual RAID on CPU All Intel VMD Controllers Create RAID Volume 8 Set Name 9 Set RAID Level ...
Страница 90: ...4 disks RAID1 Select only two disks RAID5 Select at least three 3 24 disks RAID10 Select only four disks 12 Select Strip Size Default 64KB 13 Select Create Volume 14 If another RAID is needed start again at step 9 15 Press F4 to save and reboot Figure 6 13 Created Volume without enabling RAID spanned over VMD controller Figure 6 14 Created Volume with enabling RAID spanned over VMD controller ...
Страница 91: ...device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article 2151404 2 https docs vmware com en VMware vSphere 6 5 com vmware vsphere storage doc GUID 1B56EF97 F60E 4F21 82A7 8F2A7294604D html 3 https docs vmware com en VMware vSphere 6 5 com vmware vsphere storage ...
Страница 92: ...c FAQs RMA warranty and other service extensions Direct Links for the 620U TNR System Web SYS 620U TNR specifications page X12DPU 6 motherboard page for links to the Quick Reference Guide User Manual validated storage drives etc BPN SAS3 LA26A N12 Backplane Manual Direct Links for General Support and Information Frequently Asked Questions TPM User Guide General Memory Configuration Guide X12 BMC U...
Страница 93: ...r recent security notices Supermicro Phone and Addresses Direct Links continued 7 2 BMC Interface The system supports a Baseboard Management Controller BMC interface It provides remote access monitoring and management There are several BIOS settings related to the BMC For general documentation and information on the BMC please visit our website at www supermicro com manuals other BMC_Users_Guide_X...
Страница 94: ... VROC BATTERY SXB3B SXB3A SXB3C CPU2_PORT0C CPU2_PORT1A CPU2_PORT1C CPU2_PORT0A CPU1_PORT2A P2_NVMe7 P2 DIMMF2 P2 DIMMF1 P2 DIMMH1 P2 DIMME2 P2 DIMME1 P2 DIMMG1 P2 DIMMH2 P2 DIMMG2 P2 DIMMC1 P2 DIMMC2 P2 DIMMD2 P2 DIMMD1 P2 DIMMB2 P2_NVMe10 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2_NVMe9 BP PWR2 BP PWR3 BP PWR4 NVME7 P1 DIMMC2 P1 DIMMD2 P1 DIMMC1 P1 DIMMD1 P1 DIMMA2 P1 DIMMA1 P1 DIMMB2 P1 DIMMB1 P1 DIMMF1 ...
Страница 95: ...ecommended that you use the same memory type and speed for all DIMMs in the system See Section 3 3 for memory details 3 Check for bad DIMM modules or slots by swapping modules between slots and noting the results 4 Check the power supply voltage 115V 230V switch Losing the System Setup Configuration 1 Make sure that you are using a high quality power supply A poor quality power supply may cause th...
Страница 96: ...e before or during OS installation check the following 1 Source of installation Make sure that the devices used for installation are working properly including boot devices such as CD 2 Cable connection Check to make sure that all cables are connected and working properly 3 Using the minimum configuration for troubleshooting Remove all unnecessary components starting with add on cards first and us...
Страница 97: ...onding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No memory detected in system 5 long 2 short Display memory read write error Video adapter missing or with faulty memory 1 long continuous System OH System overheat condition Additional BIOS POST Codes The AMI BI...
Страница 98: ...You can download a crash dump of status information using the BMC Dashboard The BMC manual is available at www supermicro com manuals other BMC_Users_Guide_X12_H12 pdf Check Error Log 1 Access the BMC web interface 2 Click the Server Health tab then Event Log to verify an IERR error Figure 7 4 BMC Event Log In the event of an IERR the BMC executes a crash dump You must download the crash dump and ...
Страница 99: ...ted When the system power is turned on the recovery block codes execute first Once this process is complete the main BIOS code will continue with system initialization and the remaining POST Power On Self Test routines Note 1 Follow the BIOS recovery instructions below for BIOS recovery when the main BIOS block crashes Note 2 When the BIOS recovery block crashes you will need to follow the procedu...
Страница 100: ...the BIOS binary image into a USB flash device and rename it Super ROM for the BIOS recovery use Note 2 Before recovering the main BIOS image confirm that the Super ROM binary image file you download is the same version or a close version meant for your motherboard 2 Insert the USB device that contains the new BIOS image Super ROM into your USB drive and reset the system when the following screen a...
Страница 101: ...as shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt the BIOS flashing process until it has completed 5 After the BIOS recovery process is complete press any key to reboot the system 6 Using a different system extract the BIOS package into a USB flas...
Страница 102: ...UEFI Shell prompt appears type fs to change the device directory path Go to the directory that contains the BIOS package you extracted earlier from Step 6 Enter flash nsh BIOSname at the prompt to start the BIOS update process 7 Press Del continuously during system boot to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot ...
Страница 103: ... complete When you see the screen above unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously to enter the BIOS Setup utility 11 Press F3 to load the default settings 12 After loading the default settings press F4 to save the settings and exit the BIOS Setup utility ...
Страница 104: ...he system Notes Clearing CMOS will also clear all passwords Do not use the PW_ON connector to clear CMOS JBT1 contact pads 7 8 BMC Reset The BMC can be reset using the UID button Reset Press and hold the button After six seconds the LED blinks at 2Hz The BMC resets and the reset duration is 250 ms Then the BMC starts to boot Restore factory default configuration Hold the button for twelve seconds ...
Страница 105: ...e boot block code 3 If you still cannot resolve the problem include the following information when contacting us for technical support System motherboard and chassis model numbers and PCB revision number BIOS release date version this can be seen on the initial display when your system first boots up System configuration An example of a Technical Support form is posted on our website Distributors ...
Страница 106: ...lure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems Vendor Support Filing System For issues related to Intel use the Intel IPS filing system https www intel com content www us en design support ips training welcome html For issues related to Red Hat Enterprise Linux since it is a subscription...
Страница 107: ...com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Website www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan R...
Страница 108: ...uring components in the Supermicro chassis These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Warning Definition 警告の定義 この警告サインは危険を意味します 人身事故につながる可能性がありますので いずれの機器でも動作させる前に 電気回路に含まれる危険性に注意して 標準的な事故防止策に精通して下さい 此警告符号代表危险 您正处于可能受到严重伤害的工作环境中 在您使用设备开始工作之前 必须充分意识到触电 的危险 并熟练掌握防止事故发生的标准工作程序 请根据每项警告结尾的声明号码找到此设 备的安全性警告说明的翻译文本 此警告符號代表危險 您正處於可能身體可能會...
Страница 109: ...l número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés aux cir...
Страница 110: ... risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい 警告 将此系统连接电源前 请先阅读安装说明...
Страница 111: ...내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit サーキッ ト ブレーカー この製品は 短絡 過電流 保護装置がある建物での設置を前提としています 保護装置の定格が250 V 20 Aを超えないこ とを確認下さい 警告 此产品的短路 过载电流 保护由建筑物的供电系统提供 确保短路保护设备的额定电流不大于 250V 20A 警告 此產品的短路 過載電流 保護由建築物的供電系統提供 確保短路保護設備的額定電流不大於 250V 20A Warning This product relies on the building s installation for short circuit overcurrent protectio...
Страница 112: ...ension ce produit dépend de l installation électrique du local Vérifiez que le courant nominal du dispositif de protection n est pas supérieur à 250 V 20 A 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록 해야 합니다 Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde apara...
Страница 113: ...r zu entfernen Advertencia El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d accéder à ...
Страница 114: ...ied personnel should be allowed to install replace or service this equipment 機器の設置 トレーニングを受け認定された人だけがこの装置の設置 交換 またはサービスを許可されていま す 警告 只有经过培训且具有资格的人员才能进行此设备的安装 更换和维修 警告 只有經過受訓且具資格人員才可安裝 更換與維修此設備 Warnung Das Installieren Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem qualifiziertem Personal gestattet werden امداد وحدة من انكهرباء سهك انت ز وإ انطاقت مصادر جميع من اننظاو فصم يجب قبم ان...
Страница 115: ...rtencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special too...
Страница 116: ...ès réservés L accès à une zone d accès réservé n est possible qu en utilisant un outil spécial un mécanisme de verrouillage et une clé ou tout autre moyen de sécurité 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkrege...
Страница 117: ... incorrecta Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante 電池の取り扱い 電池交換が正しく行われなかった場合 破裂の危険性があります 交換する電池はメーカーが推 奨する型 または同等のものを使用下さい 使用済電池は製造元の指示に従って処分して下さい 警告 电池更换不当会有爆炸危险 请只使用同类电池或制造商推荐的功能相当的电池更换原有电 池 请按制造商的说明处理废旧电池 警告 電池更換不當會有爆炸危險 請使用製造商建議之相同或功能相當的電池更換原有電池 請按 照製造商的說明指示處理廢棄舊...
Страница 118: ...upplies Warning This unit might have more than one power supply connection All connec tions must be removed to de energize the unit 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります ユニッ トの電源を切るためには すべての接続を取り外さなければなりません 警告 此部件连接的电源可能不止一个 必须将所有电源断开才能停止给该部件供电 警告 此裝置連接的電源可能不只一個 必須切斷所有電源才能停止對該裝置的供電 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugeführt wir...
Страница 119: ...exión para fuentes de alimentación Para cortar por completo el suministro de energía deben desconectarse todas las conexiones Attention Cette unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées אחד מספק יותר קיים אם אזהרה לרוקן מנת על החיבורים כל את להסיר יש ספק של אחד ...
Страница 120: ... bei der Wartung Advertencia Cuando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use cauti...
Страница 121: ...에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud Attention L équipement doit être installé conformément aux normes électriques nationales et locales 警告 设备安装必须符合本地与本国电气法规 警告 設備安裝必須符合本地與本國電氣法規 Warning Installation of the equipment must comply with loc...
Страница 122: ...有國家的法律和規章進行 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled according to all national laws and regulations Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales הארצי החשמל חוקי תיאום אזהרה והארציים המקומיים החשמל לחוקי תואמת להי...
Страница 123: ...eep away from moving fan blades The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing ファン ホッ トスワップの警告 警告 回転部品に注意 運転中は回転部 羽根 に触れないでく ださい シャーシから冷却ファン装 置を取り外した際 ファンがまだ回転している可能性があります ファンの開口部に 指 ドライバ ー およびその他のものを近づけないで下さい 警告 警告 危险的可移动性零件 请务必与转动的风扇叶片保持距离 当您从机架移除风扇装置 风扇可能仍在转动 小心不要将...
Страница 124: ...enez garde à ce que doigts tournevis et autres objets soient éloignés du logement du bloc ventilateur 경고 움직이는 위험한 부품 회전하는 송풍 날개에 접근하지 마세요 섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다 팬 조림품 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버 다른 물체들이 가까이 하지 않도록 배치해 주십시오 Waarschuwing Gevaarlijk bewegende onderdelen Houd voldoende afstand tot de bewegende ventilatorbladen Het is mogelijk dat de ventilator nog draait tijdens he...
Страница 125: ...下さい 他のケー ブルやアダプタを使用すると故障や火災の原因になるこ とがあります 電気用品安全法は ULまたはCSA認定のケーブル UL CSAマークがコードに表記 を Supermicro が指定する製品以外に使用するこ とを禁止しています 警告 安装此产品时 请使用本身提供的或指定的或采购的连接线 电源线和电源适配器 包含遵照当 地法规和安全要求的合规的电源线尺寸和插头 使用其它线材或适配器可能会引起故障或火灾 除了Supermicro所指定的产品 电气用品和材料安全法律规定禁止 使用未经UL或CSA认证的线材 线材上会显示UL CSA符号 警告 安裝此產品時 請使用本身提供的或指定的或採購的連接線 電源線和電源適配器 包含遵照當 地法規和安全要求的合規的電源線尺寸和插頭 使用其它線材或適配器可能會引起故障或火災 除了Supermicro所指定的產品 電氣用品和材料安全法律規定禁止 ...
Страница 126: ... שמתשהל םילבכב םיכמסומה ב UL וא ב CSA רשאכ עיפומ םהילע דוק לש UL CSA רובע לכ רצומ ילמשח רחא אלא קר רצומב רשא םאתוה י ע Supermicro דבלב دنع بيكرت جتنملا مق مادختساب تاليصوتلا ةرفوتملا وأ ةددحملا وأ مق ءارشب تالباكلا ةيئابرهكلا تالوحمو رايتلا ددرتملا عم مازتلالا نيناوقب تابلطتمو ةمالسلا ةيلحملا امب يف كلذ مجح لصوملا سباقلاو ميلسلا مادختسا يأ تالباك تالوحمو ىرخأ دق ببستي يف لطع وأ قيرح رظحي نوناق ةما...
Страница 127: ...n van het Product uitsluitend gebruik maken van de geleverde Kabels of een andere geschikte aan te schaffen Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing of brand veroorzaken Wetgeving voor Elektrische apparatuur en Materiaalveiligheid verbied h...
Страница 128: ...tel Xeon Scalable 83xx 63xx 53xx 4315 Series only Storage Drives Twelve hot swap 3 5 bays for SAS SATA NVMe SAS with additional parts Two SuperDOM Disk on Module headers PCI Expansion Slots Five PCIe 4 0 x8 One PCIe 4 0 x16 One PCIe 4 0 low profile x16 One PCIe 4 0 low profile internal x8 Input Output Network Two to four LAN ports varies by Ultra Riser Card BMC Dedicated LAN port USB Two USB 3 0 p...
Страница 129: ...32 AS NZS CISPR 32 BS EN55032 BS EN55035 CISPR 32 CISPR 24 CISPR 35 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 8 BS EN 61000 4 11 Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Product Safety 2014 35 EU LVD Directive UL CSA 62368 1 USA and Canada Electric...