background image

2

USER’S MANUAL 

Revision 1.0

SuperServer

®

5019S-ML

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes 
no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update 
or to keep current the information in this manual, or to notify any person or organization of the updates. 

Please Note: 

For the most up-to-date version of this manual, please see our website at 

www.supermicro.com

.

Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual 
at any time and without notice. This product, including software and documentation, is the property of Supermicro and/
or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except 
as expressly permitted by the terms of said license.

IN NO EVENT WILL Super Micro Computer, Inc. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, 
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT 
OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER 
MICRO COMPUTER, INC. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED 
OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, 
INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.

Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the 
State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution 
of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product. 

FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, 
may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely 
to cause harmful interference, in which case you will be required to correct the interference at your own expense.

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only 
to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. 
See 

www.dtsc.ca.gov/hazardouswaste/perchlorate

”.

WARNING: Handling of lead solder materials used in this product may expose you to lead, a 

chemical known to the State of California to cause birth defects and other reproductive harm.

The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, 
nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical 

systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic 

property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products 
for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully 
indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and 
proceedings of any kind arising out of or related to such ultra-hazardous use or sale.

Manual Revision 1.0

Release Date: November 18, 2015

Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this 

document. Information in this document is subject to change without notice. Other products and companies referred 

to herein are trademarks or registered trademarks of their respective companies or mark holders.

Copyright © 2015 by Super Micro Computer, Inc. 
All rights reserved. 

Printed in the United States of America

Содержание superserver 5019S-ML

Страница 1: ...nce when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...

Страница 2: ...se check the Supermicro website for possible updates to the manual revision level Warnings Special attention should be given to the following symbols used in this manual Warning Indicates high voltage...

Страница 3: ...8 Rear I O Ports 48 4 4 Jumpers 51 Explanation of Jumpers 51 4 5 LED Indicators 54 Chapter 5 Software 5 1 OS Installation 56 Installing the Windows OS for a RAID System 56 Installing Windows to a Non...

Страница 4: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 5: ...arby Be sure to read the precautions and considerations noted in Appendix B Main Parts List Description Part Number Quantity Air Shroud MCP 310 19007 0N 1 Heatsink passive SNK P0046P 1 Fans FAN 0087L4...

Страница 6: ...to apply or remove power from the power supply to the server Turning off system power with this button removes the main power but maintains standby power To perform many maintenance tasks you must al...

Страница 7: ...R1 FAN2FAN1 JPI2 C1 FAN3 FANA USB8 9 JF1 USB4 5 I SATA0 I SATA1 LEDPWR JSTBY1 JWD1 USB10 I SATA2 I SATA3 I SATA4 I SATA5 I SATA6 I SATA7 JSD1 JSD2 JTPM1 LE3 J23 BT1 USB2 3 JIPMB1 JD1 JI2C1 SP1 JPB1 JB...

Страница 8: ...6Gb s I SGPIO 1 2 Serial Link General Purpose I O Headers IPMI LAN Dedicated IPMI Gigabit RJ45 LAN Port J23 M 2 Socket JD1 Speaker Power LED Indicator JF1 Front Panel Control Header JIPMB1 4 pin Exter...

Страница 9: ...5 4 RTL8211E VB CG 3 2 RJ45 SPI Temp Sensor EMC1402 1 2 at diff SMBUS TPM HEADER USB 3 0 BIOS SPI 5 6 7 RMII NCSI COM1 Connector COM2 Header VGA CONN BMC Boot Flash DDR3 3 PHASE for Vcore 80W IMVP 8 D...

Страница 10: ...on the bottom of the rack are extended to the floor so that the full weight of the rack rests on them In single rack installations stabilizers should be attached to the rack In multiple rack in stall...

Страница 11: ...of the rack two screws for each bracket Installing with a Rackmount Kit This is a guideline for installing the unit into a rack with the optional rack kit MCP 290 00004 03 You should also refer to the...

Страница 12: ...step is to install the server into the rack 1 Line up the rear of the chassis rails with the front of the rack rails 2 Slide the chassis rails into the rack rails keeping the pressure even on both sid...

Страница 13: ...o a Telco Rack Installing the Server into a Telco Rack If you are installing the 5019S ML into a Telco type rack follow the directions given on the previous pages for rack installation The only differ...

Страница 14: ...vable top cover which allows easy access to the inside of the chassis Removing the Top Cover 1 Disconnect the chassis from any power source if necessary see above 2 Remove the screws securing the cove...

Страница 15: ...mponents 5 With the processor inserted into the socket inspect the four corners of the CPU to make sure that it is properly installed and flush with the socket Figure 3 5 Installing Removing the Heats...

Страница 16: ...ocket 1 Unscrew and remove the heatsink screws from the motherboard in the sequence as show in the figure above 2 Hold and gently pivot the heatsink back and forth to loosen it from the CPU Do not use...

Страница 17: ...damage to the DIMMs or slots Release Tabs Notches Press both notches straight down into the memory slot Note Visit the product page on the Supermicro website for possible updates to memory support ww...

Страница 18: ...DVD ROM or SATA drives you will need to gain access to the inside of the server by removing the top cover of the chassis Note The DVD drive is optional and does not come pre installed in the system O...

Страница 19: ...ter fan operation Fan speed is controlled by IPMI Each fan in a set has its own separate tachometer Note It is very important that the chassis top cover is properly installed for the airflow to circul...

Страница 20: ...micro p n PWS 350 1H Accessing the Inside of the System Begin by removing power from the system as described in Section 3 1 1 Grasp the two handles on either side and pull the unit straight out until...

Страница 21: ...the power supply Failure to do so may void the manufacturer s warranty on your power supply and motherboard ATX Power 24 pin Connector Pin Definitions Pin Definition Pin Definition 13 3 3V 1 3 3V 14 1...

Страница 22: ...on Disk On Module Power Connector Two power connectors for SATA DOM Disk On Module devices are located at JSD1 JSD2 Connect appropriate cables here to provide power support for your Serial Link DOM de...

Страница 23: ...rusion Pin Definitions Pin Definition 1 Intrusion Input 2 Ground M 2 Slot The X11SSH F contains one M 2 socket at J23 M 2 was formerly Next Generation Form Factor NGFF and serves to replace mini PCI E...

Страница 24: ...er Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configured to function as a suspend button with a setting i...

Страница 25: ...finitions JF1 Pin Definition 13 3 3V Standby UID Switch 14 HDD Active Power LED The Power LED connection is located on pins 15 and 16 of JF1 Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Pow...

Страница 26: ...B7 3 0 10 UID Switch Back Panel USB 0 1 2 0 Pin Definitions Pin Definition Pin Definition 1 5V 5 5V 2 USB_N 6 USB_N 3 USB_P 7 USB_P 4 Ground 8 Ground Universal Serial Bus USB Ports There are two USB 2...

Страница 27: ...therboard layout page for jumper locations Note On a two pin jumper Closed means the jumper is on both pins and Open indicates the jumper is either on only one pin or has been completely removed Conne...

Страница 28: ...Definition Pins 1 2 Reset Pins 2 3 NMI Open Disabled BIOS Recovery Use jumper JBR1 to recover the BIOS settings on the motherboard The default setting is Normal BIOS Recovery Jumper Settings Jumper S...

Страница 29: ...te Definition Link left Green Solid Amber Solid 100 Mbps 1Gbps Activity Right Amber Blinking Active LAN3 LAN4 Front Panel Activity LEDs The front panel NIC Network Interface Connection activity LED in...

Страница 30: ...Windows OS Setup screen will display 3 From the Windows OS Setup screen press the Enter key The OS Setup will automatically load all device files and then continue with the Windows installation 4 Aft...

Страница 31: ...ith SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitor...

Страница 32: ...ult text messages built in We retain the option to include omit or change any of these text messages Settings printed in Bold are the default values A indicates a submenu Highlighting such an item and...

Страница 33: ...ake the system unstable When this occurs revert the setting to the manufacture default settings Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the...

Страница 34: ...is feature to set the power state after a power outage Select Stay Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Sel...

Страница 35: ...erage power limit PL1 override The default setting is Disabled Power Limit 2 Override Select Enabled to support rapid power limit PL2 override The default setting is Enabled Power Limit 2 Use this ite...

Страница 36: ...Code Version VT d VT d Select Enabled to enable Intel Virtualization Technology support for Direct I O VT d by reporting the I O device assignments to VMM through the DMAR ACPI Tables This feature off...

Страница 37: ...o select the scale used for the slot power limit value The options are 1 0x 0 1x 0 01x and 0 001x Program PCIe ASPM After OPROM PCIe ASPM the Active State Power Management for PCI Express slots is a p...

Страница 38: ...tive State Power Management ASPM level for the PCI E device installed on the slot specified Select Auto for the system BIOS to automatically set the ASPM level based on the system configuration Select...

Страница 39: ...rity Frozen Mode The options are Enabled and Disabled SATA Port 0 Port 7 This item displays the information detected on the installed SATA drive on the particular SATA port Port 0 Port 7 The status of...

Страница 40: ...UEFI Unified Extensible Firmware Interface for network stack support The options are Enabled and Disabled IPv4 PXE Support Select Enabled to enable IPv4 PXE boot support The options are Enabled and D...

Страница 41: ...items will become available COM1 Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer use...

Страница 42: ...remote computer used by the user COM2 Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII Character set Select VT100 to ad...

Страница 43: ...onsole Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 5760...

Страница 44: ...or both versions The default setting is Auto The following are information will be displayed TPM Enabled Status TPM Active Status TPM Owner Status TXT Support Intel TXT Trusted Execution Technology he...

Страница 45: ...he user to configure Intelligent Platform Management Interface IPMI settings The following IPMI information will be displayed IPMI Firmware Revision IPMI Status System Event Log Enabling Disabling Opt...

Страница 46: ...dress for this computer Mac addresses are 6 two digit hexadecimal numbers Router IP Address This item displays the Router IP address for this computer This should be in decimal and in dotted quad form...

Страница 47: ...atures Size Key Key Source Forbidden Signatures Size Key Key Source Authorized TimeStamps Size Key Key Source 6 7 Boot Settings This submenu allows the user to configure Boot settings for this system...

Страница 48: ...Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility an...

Страница 49: ...BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press Enter Use this feature to retrieve user defined settings that were saved...

Страница 50: ...o continue the boot up process The error messages normally appear on the screen Fatal errors are those which will not allow the system to continue the boot up procedure If a fatal error occurs you sho...

Страница 51: ...it den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unf llen vertraut Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen berset...

Страница 52: ...DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source Warnung Vor dem Anschlie en des Systems an die Stromquelle die I...

Страница 53: ...che installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 250V 20A Power Disconnection Warning Warnung Das System muss von allen Quellen der Energie und vom Netzanschluss...

Страница 54: ...dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Restricted Area Waarschuwi...

Страница 55: ...alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosion...

Страница 56: ...e unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Waarschuwing Deze eenheid kan mee...

Страница 57: ...enance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Comply with Local and National Electrical Codes Warnung Die Installation...

Страница 58: ...rtencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemmi...

Страница 59: ...nschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von...

Страница 60: ...appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij het...

Страница 61: ...mount 17 3 x 1 7 x 14 5 in 439 x 43 x 368 mm W x H x D System Cooling Two sets of 4 cm counter rotating PWM fans Power Supply Model PWS 350 1H AC Input Voltages 100 240 VAC Rated Input Current 4 2A 10...