Страница 2: ...lass A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...
Страница 3: ...s and utilities https www supermicro com wftp Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support sup...
Страница 4: ...17 Chapter 2 Server Installation 2 1 Overview 18 2 2 Preparing for Setup 18 Choosing a Setup Location 18 Rack Precautions 18 Server Precautions 19 Rack Mounting Considerations 19 Ambient Operating Tem...
Страница 5: ...ystem Fans 35 Checking the Server Air Flow 37 Overheating 37 Power Supply 38 Connecting Cables 39 Power Supply Cables 39 SATA Cables 39 Fan Cables 39 Front Control Panel Cables 39 Chapter 4 Motherboar...
Страница 6: ...arting the Setup Utility 60 6 2 Main Setup 61 6 3 Advanced 63 6 4 Event Logs 85 6 5 IPMI 87 6 6 Security 90 6 7 Boot 94 6 8 Save Exit 96 Appendix A BIOS Codes Appendix B Standardized Warning Statement...
Страница 7: ...Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technic...
Страница 8: ...r is based on the A2SDV 16C TLN5F motherboard and the CSE 505 203B chassis In addition to the motherboard and chassis several important parts that are included with the system are listed below Main Pa...
Страница 9: ...d ECC non ECC UDIMM DDR4 2400MHz in four DIMM slots Chipset System on Chip Expansion Slots One PCIe 3 0 x8 slot M 2 one M Key and one B Key M Key Form Factor 2242 2280 Interface PCIe 3 0 x2 SATA B Key...
Страница 10: ...cates power is being supplied to the system power supply This LED should normally be illuminated when the system is operating 6 Reset Button The reset button is used to reboot the system Press the but...
Страница 11: ...ures Item Feature Description 1 Bracket Ear Secures the chassis into the rack 2 Control Panel Front control panel with LEDs and buttons see the previous page 3 I O Ports Input output ports see details...
Страница 12: ...al Figure 1 3 Server Rear View Rear Features The illustrations below show the features included on the rear of the chassis Server Rear Features Item Feature Description 1 Fan Internal fans 2 Power Sup...
Страница 13: ...B ON PWR JF1 RST X OH FF 2 NIC NIC 1 LED HDD LED X PWR NMI ALWAYS POPULATE DIMMx1 FIRST CPU SLOT6 PCI E 3 0 X8 CPU SLOT7 PCI E 3 0 X8 VGA KEY M PCIE3 SATA3 KEY B SATA3 USB3 COM1 LAN1 IPMI_LAN LAN5 CPU...
Страница 14: ...rtbeat Blinking Green BMC Normal UIDLED1 UID LED Solid Blue Unit Identified Connector Description BT1 Onboard Battery COM1 COM Port on the I O back panel COM2 COM Header FAN1 FAN4 FANA FANB System Fan...
Страница 15: ...Platform Module TPM Port 80 Connector JUIDB1 Unit ID Button LAN1 LAN5 LAN1 Gigabit Ethernet RJ45 Port LAN2 LAN5 10Gigabit Ethernet RJ45 Ports SLOT6 SLOT7 PCIe 3 0 x8 Slots use SLOT 6 or SLOT 7 only se...
Страница 16: ...anual Figure 1 5 Chipset System Block Diagram Note This is a general block diagram and may not exactly represent the features on your motherboard See the System Specifications appendix for the actual...
Страница 17: ...ng uninterruptible power supply UPS to protect the server from power surges voltage spikes and to keep your system operating in case of a power failure Review the electrical and general safety precaut...
Страница 18: ...Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave enough...
Страница 19: ...in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep the front door of the rack and all covers panels on the servers closed...
Страница 20: ...connections to the branch circuit i e the use of power strips etc All power cords must be plugged into sockets that have an earth ground To prevent bodily injury when mounting or servicing this unit...
Страница 21: ...rack unit you are using 1 Gather the four mounting screws shipped with the system 2 Align the mounting holes of the chassis with the thru holes of the rack 3 Insert the mounting screws into the thru h...
Страница 22: ...Telco Two Post Style Rack To install the system into a Telco style two post rack use two L shaped brackets on either side of the chassis four total 1 Determine how far the server will extend out the f...
Страница 23: ...umbers given Installation or replacement of most components require that power first be removed from the system Please follow the procedures given in each section 3 1 Removing Power Use the following...
Страница 24: ...own the system as described in Section 3 1 2 Remove one screw from the chassis rear and two screws from each chassis side 3 Lift the cover up and off the chassis Caution Except for short periods of ti...
Страница 25: ...performance Refer to the table on the next page for the recommended DIMM population order ESD Precautions Electrostatic Discharge ESD can damage electronic com ponents including memory modules To avo...
Страница 26: ...ollow the table below when populating memory Memory Population Balanced DIMMA1 DIMMB1 DIMMA2 DIMMB2 Total System Memory 4GB 4GB 8GB 4GB 4GB 4GB 4GB 16GB 8GB 8GB 16GB 8GB 8GB 8GB 8GB 32GB 16GB 16GB 32G...
Страница 27: ...MM modules in pairs to activate memory interleav ing BAR CODE COM2 DESIGNED IN USA A2SDV 16C TLN5F REV 1 1 JIPMB1 JMD2 JMD1 JTGLED1 JPW1 JPI2C1 JSD1 SRW2 SRW3 SRW4 SRW1 JUIDB JPL1 1 JWD1 JPG1 JBR1 JPM...
Страница 28: ...th ends of the DIMM slot to unlock it Side Notches Release Tabs 3 Identify the notches on the side and bottom of the DIMM module 4 Align the bottom notch on DIMM module with the receptive point in the...
Страница 29: ...tall an M 2 card first locate the connector and the standoff on the motherboard 1 Remove the screw from the standoff and set aside 2 Remove the old M 2 card 3 Insert a new M 2 card into the slot 4 Ali...
Страница 30: ...JPV1 FANB JTPM1 JNCSI1 JL1 JRT4 1 JRT3 I SATA1 I SATA0 UIDLED1 CM CODE LEDBMC eUSB ON PWR JF1 RST X OH FF 2 NIC NIC 1 LED HDD LED X PWR NMI ALWAYS POPULATE DIMMx1 FIRST CPU SLOT6 PCI E 3 0 X8 CPU SLO...
Страница 31: ...h the regulations set up by your local hazardous waste management agency to dispose of your used battery properly Figure 3 6 Installing the Onboard Battery Motherboard Battery Caution There is a dange...
Страница 32: ...stall a PCIe x8 card Note Install the expansion card after installing the 2 5 disk drives Assemble the PCIe Expansion Card Riser Card and Brackets 1 Remove power as described in Section 3 1 and remove...
Страница 33: ...t the expansion card into the riser card 2 Insert the riser card and PCI card assembly into the motherboard 3 Secure the PCI slot bracket to the chassis with the clip Figure 3 8 Assemble the PCIe Expa...
Страница 34: ...power as described in Section 3 1 and remove the chassis cover 2 If necessary remove the PCI expansion card from the chassis 3 Remove the drive brackets from the chassis 4 Insert the SSDs into the dri...
Страница 35: ...g fans will ramp up to full speed the overheat fan fail LED on the control panel will blink on and off Replace any failed fan at your earliest convenience with the same type and model Replacing a Syst...
Страница 36: ...ual 36 6 Install a new fan into the drive tray 7 Connect the fan to the motherboard 8 Reinstall the chassis cover 9 Reconnect the power cord and power up the system 10 Check that the overheat fan fail...
Страница 37: ...y system heat status See Control Panel in Chapter 1 for details Overheating There are several possible responses if the system overheats If the server overheats 1 Use the overheat fan fail LED to dete...
Страница 38: ...cribed in Section 3 2 2 Disconnect all wiring from the power supply 3 Remove two screws holding the power supply to the chassis rear From the underside of the chassis remove two screws holding the pow...
Страница 39: ...nect it in the same configuration Power Supply Cables An ATX 24 pin power cable JPW1 supplies 12V power to the motherboard SATA Cables Two Y split SATA power cables connect the SATA drives to the powe...
Страница 40: ...e system 4 1 Power Connections Main ATX Power Supply Connector The primary power supply connector JPW1 meets the ATX SSI EPS 12V specification ATX Power 24 pin Connector Pin Definitions Pin Definition...
Страница 41: ...fan headers FAN1 FAN4 FANA FANB These headers are backwards compatible with the traditional 3 pin fans However fan speed control is available for 4 pin fans only by Thermal Management via the IPMI 2 0...
Страница 42: ...2 8 GP5 GPP_F3 9 GP6 GPP_F0 10 GP7 GPP_F4 Disk On Module Power Connector The Disk On Module DOM power connector at JSD1 provides 5V power to a solid state DOM storage device connected to one of the SA...
Страница 43: ...pin definitions External I2 C Header Pin Definitions Pin Definition 1 Data 2 GND 3 Clock 4 NC TPM Port 80 Header The JTPM1 header is used to connect a Trusted Platform Module TPM Port 80 which is avai...
Страница 44: ...er to the tables below for pin definitions SATA 3 0 Port Pin Definitions Pin Signal 1 Ground 2 SATA_TXP 3 SATA_TXN 4 Ground 5 SATA_RXN 6 SATA_RXP 7 Ground M 2 Connection TheA2SDV 16C TLN5F has two M 2...
Страница 45: ...LAN2 Active LED Reset Button HDD LED PWR LED Reset PWR 3 3V Stby 2 5V Stby Ground 2 5V Stby Ground LAN3 Active LED Power Fail LED UID 3 3V NMI 3 3V X X 1 2 19 20 3 3V Power Button The Power Button con...
Страница 46: ...vides warnings of overheat or fan failure Refer to the tables below for pin definitions OH Fan Fail Indicator Status State Definition Off Normal On Overheat Flashing Fan Fail OH Fan Fail LED Pin Defin...
Страница 47: ...fer to the table below for pin definitions Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 PWR LED NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 Refer...
Страница 48: ...1 VGA 4 LAN1 IPMI 8 LAN2 1 9 8 7 6 5 4 3 2 10 11 VGA Port A VGA video port is located near LAN ports 4 5 on the I O back panel Use this connection for a VGA display COM Port and Header The motherboard...
Страница 49: ...USB_P 6 USB_P 7 Ground 8 Ground 9 Key 10 NC Type A USB 3 0 Pin Definitions Pin Definition 1 VBUS 2 D 3 D 4 Ground 5 StdA_SSRX 6 StdA_SSRX 7 GND_DRAIN 8 StdA_SSTX 9 StdA_SSTX Unit Identifier Button UI...
Страница 50: ...d Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clear...
Страница 51: ...ce the system to operate in the manufacturing mode which will allow the user to flash the system firmware from a host server for system setting modifications Refer to the table below for jumper settin...
Страница 52: ...etting is Disabled SMBus to PCI Slots Jumper Settings JI2 C1 Setting JI2 C2 Setting Definition JI2 C1 Pins 1 2 JI2 C2 Pins 1 2 Enabled Default JI2 C1 Pins 2 3 JI2 C2 Pins 2 3 Disabled PCIe Slot Select...
Страница 53: ...oftware to disable it Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset Default Pins 2 3 NMI Open Disabled IPMI Shared LAN Port Selection JNCSI1 is used to set a specific LAN port for...
Страница 54: ...ve Activity LED Link LED 10G Link LED LAN2 3 4 5 LED Color Definition Off No Connection 10 Mbps 100 Mbps Amber 1 Gbps Green 10 Gbps BMC Heartbeat LED LEDBMC is the BMC heartbeat LED When the LED is bl...
Страница 55: ...r website at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a...
Страница 56: ...ad the driver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID cho...
Страница 57: ...nother option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...
Страница 58: ...nagement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server...
Страница 59: ...For general documentation and information on IPMI please visit our website at http www supermicro com products nfo IPMI cfm BMC ADMIN User Password For security each system is assigned a unique defaul...
Страница 60: ...sed such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options...
Страница 61: ...ht System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time...
Страница 62: ...9A FN5T User s Manual Memory Information Total Memory This item displays the total size of memory available in the system Memory Speed This item displays the default speed of the memory modules instal...
Страница 63: ...re Quiet Boot Use this feature to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead...
Страница 64: ...the power state after a power outage Select Power Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Select Last State t...
Страница 65: ...ckage C State limit Use this item to set the limit on the C State package register The options are No Pkg C State No S0Ix and No Limit The feature above is not available when CPU C State is disabled M...
Страница 66: ...e legacy operating systems that cannot support processors with extended CPUID functions The options are Disable and Enable Execute Disable Bit Set to Enable for Execute Disable Bit support which will...
Страница 67: ...he setting PL1 Power Level Use this feature to define the Running Average Power Limit RAPL power limit 1 in Watts The default setting is 31 Use the or keys to define the setting PL2 Power Level Use th...
Страница 68: ...ature to set the maximum memory frequency for onboard memory modules The options are DDR 1600 DDR 1867 DDR 2133 and DDR 2400 MMIO Size BMBOUND Base Use this feature to select the memory mapped IO size...
Страница 69: ...he memory refresh rate The options are 1x 2x and 1x 2x 4x CKE Power Down Clock enable CKE Power Down controls the low power down for the memory The options are Disabled Active Power Down and Precharge...
Страница 70: ...should be claimed by the XHCI driver The settings are Enabled and Disabled Port 60 64 Emulation Select Enabled for I O port 60h 64h emulation support which in turn will provide complete legacy USB ke...
Страница 71: ...t to Enabled SATA 0 ALPM will be available for configuration SATA 1 ALPM Use this feature to enable or disable Aggressive Link Power Management The options are Enabled and Disabled SATA 1 SGPIO LED Us...
Страница 72: ...lue of an edge detect or the value of an image binary pixel of a device is from 0 to 1 select Enabled to allow the PCH to start a COMRESET initialization sequence on this device The options are Enable...
Страница 73: ...options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes Maximum Read Request Select Auto for the system BIOS to automatically set the maximum size for a read request for a...
Страница 74: ...oard Network Stack Select Enabled to enable PXE Preboot Execution Environment or UEFI Unified Extensible Firmware Interface for network stack support The options are Enabled and Disabled If Network St...
Страница 75: ...F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Configuration COM2 Serial Port 2 Select Enabled to ena...
Страница 76: ...e or more bytes The options are VT100 VT100 VT UTF8 and ANSI COM1 Bits Per second Use this item to set the transmission speed for a serial port used in Console Redirection Make sure that the same spee...
Страница 77: ...d COM1 Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled COM1 Resolution 100x31 Select Enabl...
Страница 78: ...er of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data bits in transmissio...
Страница 79: ...e allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Mgmt Port The feature selects a serial port in...
Страница 80: ...e system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitoring The options are Disabled and Enabled Trusted Computin...
Страница 81: ...atus TPM Owner Status The features from here to Device Select on the next page are displayed if a TPM 2 0 module is detected TPM20 Device Found Vendor IFX Firmware Version 5 51 Configuration Security...
Страница 82: ...em to disable or enable storage hierarchy for cryptographic protection The options are Disabled and Enabled Endorsement Hierarchy Use this item to disable or enable endorsement hierarchy for privacy c...
Страница 83: ...el Ethernet Connection X553 X557 AT 10GBASE T 00 25 These features display the following information NIC Configuration Link Speed Use this feature to change the link speed and duplex for the current p...
Страница 84: ...ddress This item displays the PCI address for this computer PCI addresses are three two digit hexadecimal numbers Link Status This item displays the connection status MAC Address This item displays th...
Страница 85: ...ature to enable or disable PCIe error logging suport The options are Disabled and Enabled Memory ELog Support Use this feature to enable or disable memory error logging suport The options are Disabled...
Страница 86: ...Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Enabled and Disabled MECI Multiple Event Count Increment Enter the increment value for the mu...
Страница 87: ...in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings Erase SEL Select...
Страница 88: ...e feature above is set to Yes Configuration Address Source and VLAN will become available for configuration Configuration Address Source Use this feature to select the source of the IP address for thi...
Страница 89: ...PMI VLAN function The options are Disable and Enable IPMI Function Support Use this feature to enable IPMI support The options are Disabled and Enabled When this feature is disabled the system powers...
Страница 90: ...he BIOS Setup utility The options are Setup and Always Administrator Password Use this feature to set the administrator password which is required to enter the BIOS setup utility The length of the pas...
Страница 91: ...Factory Keys Select Yes to restore all factory keys to the default settings The options are Yes and No Key Management This submenu allows the user to configure the following Key Management settings P...
Страница 92: ...atabase from the manufacturer s defaults to the existing DB Select No to load the DB from a file The options are Yes and No Forbidden Signatures Set New Select Yes to load the DBX from the manufacture...
Страница 93: ...EFI CERT RSA2048 bin d EFI SERT SHA256 bin 2 EFI Time Based Authenticated Variable Set New Select Yes to load the OSRecovery Signature from the manufacturer s defaults Select No to load the OSRecovery...
Страница 94: ...evices in the system The options are LEGACY UEFI and DUAL Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system boots from Press Enter on each entry from to...
Страница 95: ...etected devices The options are the list of detected boot device s and Disable UEFI Network Drive BBS Priorities Boot Option This feature sets the system boot order of detected devices The options are...
Страница 96: ...nd Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press...
Страница 97: ...tore User Defaults from the Exit menu and press Enter Use this feature to retrieve user defined settings that were saved previously Boot Override This feature allows the user to override the Boot Opti...
Страница 98: ...ith your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The table below lists some common errors and their corresponding beep co...
Страница 99: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...
Страница 100: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar e...
Страница 101: ...erken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aa...
Страница 102: ...taci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het syste...
Страница 103: ...ientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l i...
Страница 104: ...gungsteilmodulen entfernt wird bevor es auf den Chassisinnenraum zur ckgreift um Systemsbestandteile anzubringen oder zu entfernen Advertencia El sistema debe ser disconnected de todas las fuentes de...
Страница 105: ...mkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment...
Страница 106: ...tion Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation in...
Страница 107: ...so a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...
Страница 108: ...lable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrec...
Страница 109: ...nt aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All...
Страница 110: ...oos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attenti...
Страница 111: ...Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques...
Страница 112: ...plir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geb...
Страница 113: ...onale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled acco...
Страница 114: ...cyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving par...
Страница 115: ...destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient...
Страница 116: ...oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro UL C...
Страница 117: ...sur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto...
Страница 118: ...nsluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing o...
Страница 119: ...ace PCIe 3 0 x2 SATA USB3 Input Output Two SATA 3 0 ports Two onboard COM connections one via header Five USB 3 0 ports four in front one Type A onboard Two USB 2 0 header Network Quad LAN with 10GBas...
Страница 120: ...32 EN55032 EN55035 CISPR 24 EN 61000 3 2 EN 61000 3 3 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Green Environment 2011 65 EU RoHS Directive EC 1907 2...
Страница 121: ...ou can download a crash dump of status information using IPMI The IPMI manual is available at https www supermicro com solutions IPMI cfm Check IPMI Error Log 1 Access the IPMI web interface 2 Click t...
Страница 122: ...em remains in a failed state Do not check this box until after the dump file has been sent to Support Downloading the Crash Dump File 1 In the IPMI interface click the Miscellaneous tab then the Troub...
Страница 123: ...ccur due to a software tool issue see image below or an unexpected power outage during BIOS updates BIOS Boot Block Corruption Occurrence When a BIOS boot block is corrupted due to an unexpected power...
Страница 124: ...g Jumper JBR1 1 Power down the system 2 Close pins 2 3 on jumper JBR1 and power on the system 3 Follow the BIOS recovery SOP listed in the previous chapter Appendix D 4 After completing the steps abov...