background image

USER’S MANUAL 

Revision 1.0

SuperServer

®

420GP-TNR

Содержание SuperServer 420GP-TNR

Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 420GP TNR...

Страница 2: ...Class A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer...

Страница 3: ...d utilities https www supermicro com wdl driver Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support s...

Страница 4: ...able 18 Chapter 2 Server Installation 2 1 Overview 19 2 2 Unpacking the System 19 2 3 Preparing for Setup 19 Choosing a Setup Location 19 Rack Precautions 20 Server Precautions 20 Rack Mounting Consid...

Страница 5: ...m the CPU Socket 37 Removing the Processor Carrier Assembly from the PHM 38 Removing the Processor from the Processor Carrier Assembly 39 3 5 Memory 40 Memory Support 40 Intel Optane PMem 200 Series M...

Страница 6: ...on CPU VROC 75 Requirements and Restrictions 75 Supported SSDs and Operating Sytems 75 Additional Information 76 Hardware Key 76 Enabling NVMe RAID 77 Status Indications 80 Hot Swap Drives 80 Hot unpl...

Страница 7: ...FI BIOS Image 88 Recovering the Main BIOS Block with a USB Device 88 7 7 CMOS Clear 93 7 8 Where to Get Replacement Components 94 7 9 Reporting an Issue 94 Technical Support Procedures 94 Returning Me...

Страница 8: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 9: ...RDIMM LRDIMM or 18TB Intel Optane DDR4 2666 DCPMM RDIMM LRDIMM DCPMM Drive Support 24 hot swap 2 5 Gen4 NVMe SAS3 SATA3 drive bays Expansion Slots 12 PCIe 4 0 X16 One Supermicro AIOM OCP 3 0 Two M 2 N...

Страница 10: ...es Refer to Appendix B for additional specifications Front View Figure 1 1 Front View Logical Storage Drive Numbers Item Description 0 23 24 hot swap 2 5 Gen4 NVMe SAS3 SATA3 drive bays hybrid 0 8 6 5...

Страница 11: ...onfigurations refer to the VROC appendix in this manual Drive Carrier LED Indicators Color Blinking Pattern Behavior for Device Activity LED Blue Solid On Idle SAS NVMe drive installed Blue Blinking I...

Страница 12: ...N1 LED Indicates network activity on LAN1 when flashing NIC LAN2 LED Indicates network activity on LAN2 when flashing Power Fail LED Indicates a power supply module has failed Information LED Alerts o...

Страница 13: ...0 x16 slot CPU1 via PLX PCIe 4 0 x16 slot CPU1 via PLX PCIe 4 0 x16 slot CPU1 direct PCIe 4 0 x16 slot CPU2 via PLX PCIe 4 0 x16 slot CPU2 via PLX PCIe 4 0 x16 slot CPU2 via PLX PCIe 4 0 x16 slot CPU2...

Страница 14: ...emperature Over voltage under voltage etc OFF 1Hz Blink Amber AC present only 12vsb on PS off 1Hz Blink Green OFF Output ON and OK Green OFF AC cord unplugged and in redundant mode OFF Amber System Fe...

Страница 15: ...2x dual in line memory module slots Processors 2x 3rd Generation Intel Xeon Scalable processors Fans 8x 9 cm heavy duty fans 1 3 System Architecture This section covers the locations of the system ele...

Страница 16: ...onents of the overall system CPU1 PLX PCIE X16 PCIE X16 PCIE X16 PCIE X16 PCIE X16 PCIE X16 PCIE X16 PCIE X16 PCIE X16 PCIE X16 PCIE X16 PCIE X16 PLX CPU2 AIOM OCP 3 0 PCH IO 8x SATA3 BMC 2x M 2 NVMe...

Страница 17: ...GPU PWR2 P2 PCIE4B P2 PCIE4A P1 PCIE4A P1 PCIE4B P2 PCIE1A P2 PCIE1B P2 PCIE2A P2 PCIE2B P2 PCIE3A P2 PCIE3B P1 PCIE1B P1 PCIE1A P1 PCIE2B P1 PCIE2A P1 PCIE3B P1 PCIE3A GPU PWR1 I O RISER USB BMC LAN...

Страница 18: ...trusion header JM2_1 JM2_2 M 2 PCIe 3 0 x4 slots supported by PCH supports M Key 2280 and 22110 JPW_STBY1 4 pin power connector standby JPWR1 10 8 pin power connectors GPU JPW1 4 PSU power connectors...

Страница 19: ...e server It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated It will also require a grounded AC pow...

Страница 20: ...y precautions in Appendix A Determine the placement of each component in the rack before you install the rails Install the heaviest server components at the bottom of the rack first and then work your...

Страница 21: ...tion should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit i...

Страница 22: ...This rail will fit a rack between 26 5 and 36 4 deep Identifying the Inner Rack Rails The chassis package includes one pair of rack rail assemblies in the rack mounting kit Each assembly consists of...

Страница 23: ...ails on the Chassis Installing the Inner Rails 1 Identify the left and right side inner rails Place the correct inner rail on the side of the chassis aligning the hooks of the chassis with the inner r...

Страница 24: ...e outer rails to the rack 4 Pull out the rear of the outer rail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the squ...

Страница 25: ...even on both sides You may have to depress the locking tabs while inserting When the server has been pushed completely into the rack the locking tabs should click into the locked position 3 If screws...

Страница 26: ...o have sufficient assistance supporting the chassis when removing it from the rack Use a lift Removing the Chassis from the Rack 1 Pull the chassis forward out the front of the rack until it stops 2 P...

Страница 27: ...Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installi...

Страница 28: ...e chassis 3 Slide the cover toward the rear of the chassis See Figure 3 1 4 Lift the cover from the chassis Warning Except for short periods of time do not operate the server without the cover in plac...

Страница 29: ...Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any PCB printed circuit board from its antistatic bag Handle PCBs by their edges only do...

Страница 30: ...unplug the AC power cords from all power supplies Check that the plastic protective cover is on the CPU socket and that none of the socket pins are bent If they are contact your retailer When handling...

Страница 31: ...tic Sensitive Devices section earlier in this chapter 1 Hold the processor with the gold pins LGA lands facing down Locate the gold triangle at the corner of the processor and the corresponding hollow...

Страница 32: ...ess the other end down until it snaps into latch 2 6 After the processor is placed inside the carrier examine the four sides of the processor making sure that the processor is properly seated on the c...

Страница 33: ...to the two triangle cutouts A B located at the diagonal corners of the heatsink as shown in the drawing below 2 Hold the processor carrier assembly upside down to locate the triangles on the processor...

Страница 34: ...cket for Installation The CPU socket comes with a plastic protective cover which needs to be removed before installing the Processor Heatsink Module PHM Do this by gently squeezing the grip tabs then...

Страница 35: ...View Top View Unlatched State a b c d a b c d Threaded Fasteners CPU Socket Pin1 Threaded Fastener CPU Socket Installing the PHM into the CPU Socket After assembling the Processor Heatsink Module PHM...

Страница 36: ...aligned gently place the heatsink on the CPU socket making sure that each peek nut is properly attached to its corresponding threaded fastener Latched State Top View Rotating Wire Rotating Wire 6 Pre...

Страница 37: ...shut down the system and unplug the AC power cord from all power supplies 1 Use a t30 bit screwdriver to loosen the four peek nuts on the heatsink in the sequence of A B C and D A B C D Peek Nut 2 Onc...

Страница 38: ...please follow the steps below 1 Detach the four plastic clips marked a b c d on the processor carrier assembly from the four corners of the heatsink marked A B C D as shown below 2 When all plastic cl...

Страница 39: ...sor from the processor carrier by following the steps below 1 Unlock the lever from its locked position and push it upwards to disengage the processor from the processor carrier as shown below right L...

Страница 40: ...and selected Silver processors P1 DIMMB2 P2 DIMMB2 memory slots are reserved for Intel Optane PMem 200 Series only Memory speed support depends on the processors used in the system Memory Support for...

Страница 41: ...1 CPU2 P2 DIMMA1 P2 DIMME1 P2 DIMMC1 P2 DIMMG1 P2 DIMMB1 P2 DIMMF1 P2 DIMMD1 P2 DIMMH1 2 CPUs 18 DIMMs CPU1 P1 DIMMA1 P1 DIMME1 P1 DIMMC1 P1 DIMMG1 P1 DIMMB1 P1 DIMMF1 P1 DIMMD1 P1 DIMMH1 P1 DIMMA2 P1...

Страница 42: ...R4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 PMem DDR4 DDR4 DDR4 DDR4 PMem DDR4 DDR4 DDR4 DDR4 PMem DDR4 DDR4 DDR4 DDR4 DDR4 8 1 AD One x1 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 PMem DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 PMem DDR...

Страница 43: ...mory population rules Ensure the same DDR4 DIMM type and capacity are used for each DDR4 PMem popu lation If the system detects an unvalidated configuration then the system issues a BIOS warn ing The...

Страница 44: ...ush both ends of the module straight down into the slot until the module snaps into place Notches Push both ends straight down into the memory slot DIMM Removal Press both release tabs on the ends of...

Страница 45: ...the motherboard Replacing the Battery Begin by removing power from the system 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the holder 2...

Страница 46: ...drives are hot swappable and can be removed or replaced without powering down the chassis Enterprise NVMe SAS or SATA HDDs only are recommended Removing Hard Drives and their Carriers from the Hard D...

Страница 47: ...t the hard drive is on the top of the carrier and the release button is on the right side When the carrier reaches the rear of the bay the release handle will retract 5 Push the handle in until it cli...

Страница 48: ...ebuild drive for SAS SATA NVMe with RSTe support Red Blinking with two blinks and one stop at 1 Hz Hot spare for SAS SATA NVMe with RSTe support Red On for five seconds then off Power on for SAS SATA...

Страница 49: ...SSD 2 Select Device Group and Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorized by the CPLD design architectu...

Страница 50: ...as failed Never run the server for an extended period of time with the chassis cover open 2 Press the fan housing lever to unlock the fan from the bracket 3 While applying pressure to fan housing leve...

Страница 51: ...t powering down the system Replace with the same model Replacement modules can be ordered directly from Supermicro An amber light on the power supply is illuminated when the power is switched off An g...

Страница 52: ...system See Figures 3 3 and 3 4 for topology for the daughterboards in 420GP TNR systems Installing Expansion Cards 1 Power down the system and open the chassis cover 2 Remove the screw holding the ch...

Страница 53: ...53 Chapter 3 Maintenance and Component Installation Figure 3 9 Installing the Daughter Board...

Страница 54: ...them in the same manner Proper cable routing is important in maintaining proper airflow through the system Online Cable Matrix SYS 420GP TNR DUAL ROOT CBL SAST 1231 85 CBL SAST 1231 85 CBL SAST 1215 8...

Страница 55: ...e LED blinks at 2 Hz The BMC resets and the reset duration is 250 ms Then the BMC starts to boot Restore factory default configuration Hold the button for twelve seconds The LED blinks at 4 Hz while d...

Страница 56: ...ne to provide power to the system In addition three 8 pin 12VDC power connectors JPW11 13 are used to provide power to backpanel devices Another ten 8 pin power connectors JPWR1 5 JPWR6 10 are used fo...

Страница 57: ...or 4 pin fans only by Thermal Management via the BMC 2 0 interface Refer to the table below for pin definitions 6 pin Fan Header Pin Definitions Pin Definition 1 Ground 2 4A 12V 3 Tachometer 4 PWM_Con...

Страница 58: ...the chassis is opened Refer to the table below for pin definitions Chassis Intrusion Pin Definitions Pin Definition 1 Intrusion Input 2 Ground Trusted Platform Module Header Pin Definitions Pin Defin...

Страница 59: ...Me RAID support install a VROC RAID Key on JRK1 as shown in the illustration below Intel VROC Key Pin Definitions Pin Definition 1 Ground 2 3 3V Standby 3 Ground 4 PCH RAID Key VROC Key VROC Key Heade...

Страница 60: ...3 3V Stby Ground 19 Ground 20 1 2 Ground Key Key Power Fail LED NIC2 Link LED NMI 3 3V Red OH Fan Fail PWR Fail Blue UID LED 3 3V Red NIC1 Link LED NIC2 Active LED Blue Front Control Panel JF1 LED In...

Страница 61: ...on 5 3 3V 6 Signal Reset Button The Reset Button connection is located on pins 3 and 4 of JF1 Momentarily contacting both pins will reset the system Refer to the table below for pin definitions Power...

Страница 62: ...pports a front UID switch The front UID switch functions in the same way as the rear UID switch and both are for input only When this LED is blinking green it indicates HDD activity Attach a cable to...

Страница 63: ...the I O riser card AOM PIG I2G Universal Serial Bus USB Ports The motherboard also has one front access USB 3 0 headers J36 USB3 4 The onboard headers can be used to provide front side USB access with...

Страница 64: ...ely removed Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accident...

Страница 65: ...system to operate in the manufacturing mode which will allow the user to flash the system firmware from a host server for system setting modifications Refer to the table below for jumper settings The...

Страница 66: ...for more information AIOM OCP card power good Indicator LED Color Definition Off AIOM OCP card not connected Green AIOM OCP card powered on BMC Heartbeat LED A BMC Heartbeat LED is located at LEDM1 on...

Страница 67: ...r s guide posted on our website at http www supermicro com M 2 Slots Two hybrid M 2 slots are located at JM2_1 and JM2_2 M 2 was formerly known as Next Generation Form Factor NGFF and serves to replac...

Страница 68: ...supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive...

Страница 69: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...

Страница 70: ...red Another option is to go to the Supermicro website at http www supermicro com Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or disk...

Страница 71: ...a email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 M...

Страница 72: ...are related to BMC For general documentation and information on BMC visit our website at www supermicro com en solutions management software bmc resources BMC ADMIN User Password For security each sy...

Страница 73: ...ap 2 5 NVMe drive tray orange tab w key lock MCP 220 00127 0B 1 24 Black Gen3 hot swap 2 5 tool less SAS SATA HDD tray MCP 220 00147 0B 1 16 Add on Cards AOC VROCPREMOD AOC VROCSTNMOD CacheVaults BTR...

Страница 74: ...SAS3 HDDs AOM TPM 9670V or AOM TPM 9671V n a TPM security module 6 3 Network Cards Network Card Options Part Number Description AOC S40G i2Q Standard LP 2 port 40GbE controller based on Intel Fortvill...

Страница 75: ...Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise Intel...

Страница 76: ...he key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd party SSDs...

Страница 77: ...h PStack based on the your model server For M 2 NVMe or NVMe AIC enable the VMD according to which AOC card slot it used Examples for some U 2 configurations follow 6 Press F4 to save the configuratio...

Страница 78: ...78 Chapter 6 Optional Components Figure 6 2 BIOS VMD Setting Examples...

Страница 79: ...thout enabling RAID spanned over VMD Controller Figure 6 4 Created Volume with enabling RAID spanned over VMD Controller 13 Select Strip Size Default 64KB 14 Select Create Volume 15 If another RAID is...

Страница 80: ...evice Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article 215140...

Страница 81: ...ls BIOS BMC drivers etc FAQs RMA warranty and other service extensions Direct Links for the 420GP TNR System SYS 420GP TNR specifications page X12DPG OA6 motherboard page for links to the Quick Refere...

Страница 82: ...rity notices Supermicro Phone and Addresses Direct Links continued 7 2 Baseboard Management Controller BMC The system supports the a Baseboard Management Controller BMC BMC is used to provide remote a...

Страница 83: ...upply 4 Make sure that no short circuits exist between the motherboard and chassis 5 Disconnect all cables from the motherboard including those for the keyboard and mouse 6 Remove all add on cards 7 I...

Страница 84: ...ommended that you use the same memory type and speed for all DIMMs in the system See Section 3 3 for memory details 3 Check for bad DIMM modules or slots by swapping modules between slots and noting t...

Страница 85: ...before or during OS installation check the following 1 Source of installation Make sure that the devices used for installation are working properly including boot devices such as CD 2 Cable connectio...

Страница 86: ...nding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No memory de...

Страница 87: ...ovide information to support staff You can download a crash dump of status information using BMC Check the BMC Error Log 1 Access the BMC web interface 2 Click the Server Health tab then Event Log to...

Страница 88: ...ed When the system power is turned on the recovery block codes execute first Once this process is complete the main BIOS code will continue with system initialization and the remaining POST Power On S...

Страница 89: ...e BIOS binary image into a USB flash device and rename it Super ROM for the BIOS recovery use Note 2 Before recovering the main BIOS image confirm that the Super ROM binary image file you download is...

Страница 90: ...shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt...

Страница 91: ...EFI Shell prompt appears type fs to change the device directory path Go to the directory that contains the BIOS package you extracted earlier from Step 6 Enter flash nsh BIOSname at the prompt to star...

Страница 92: ...complete When you see the screen above unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously...

Страница 93: ...n the system completely 2 Remove the cover of the chassis to access the motherboard 3 Remove the onboard battery from the motherboard 4 Short the CMOS pads with a metal object such as a small screwdri...

Страница 94: ...boot block code 3 If you still cannot resolve the problem include the following information when contacting us for technical support System motherboard and chassis model numbers and PCB revision numbe...

Страница 95: ...lure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems Vendor Support Filing System For issues r...

Страница 96: ...om Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support sup...

Страница 97: ...sistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These war...

Страница 98: ...idere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el te...

Страница 99: ...ient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het e...

Страница 100: ...i n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het systeem...

Страница 101: ...del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l installa...

Страница 102: ...g a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre...

Страница 103: ...s aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warnun...

Страница 104: ...n Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation in res...

Страница 105: ...na de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s une...

Страница 106: ...e ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta R...

Страница 107: ...evolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All connec...

Страница 108: ...te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention C...

Страница 109: ...tencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circu...

Страница 110: ...con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden...

Страница 111: ...elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled according...

Страница 112: ...lage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving parts...

Страница 113: ...rnilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient toujo...

Страница 114: ...r CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro UL CSA U...

Страница 115: ...code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto utilic...

Страница 116: ...uitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing of b...

Страница 117: ...ots for up to 8TB 3DS ECC DDR4 3200 RDIMM LRDIMM or 18TB Intel Optane DDR4 2666 DCPMM RDIMM LRDIMM DCPMM Storage Drives 12x PCI E 4 0 X16 1x Supermicro AIOM OCP 3 0 Two M 2 NVMe SATA3 PCI Expansion Sl...

Страница 118: ...60 Hz Rated Output Power 1000W 100 127Vac 1800W 200 220Vac 1980W 220 230Vac 2000W 230 240Vac 2000W 220 240Vac UL only Rated Output Voltages 12V Max 83A Min 0A 100 127Vac Max 150A Min 0A 200 220Vac Ma...

Страница 119: ...EN BS 61000 4 6 EN BS 61000 4 8 EN BS 61000 4 11 Green Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Product Safety 2014 35 EU LVD Direct...

Отзывы: