10
SuperServer 4029GP-TVRT User's Manual
Control Panel Features
Item
Feature
Description
1
BMC reset/UID Button
This button is dual function, depending on the JBMC_BTN jumper (see
Chapter 4). It either:
– Resets the Baseboard Management controller (BMC) that provides
IPMI support.
– Turns on or off the blue unit identifier (UID) light, used to locate the
server in large server banks.
2
System Reset Button/
Information LED
The reset button is used to reboot the server. The LED indicator in the
button alerts an operator to several states, as noted in the table below
3
Power Button
The main power switch applies or removes primary power to the
server; standby power is maintained. It is green when the system is
operating. It is amber when the system is off, but the power supplies
are still connected and providing standby power.
Information LED
Status
Description
Continuously on and
red
An overheat condition has occurred.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure; check for an inoperative fan.
Solid blue
UID has been activated locally to locate the
server in a rack environment.
Blinking blue
UID has been activated using IPMI to locate the
server in a rack environment.
Figure 1-1. Control Panel View
1.4 Server Chassis Features
Control Panel
The switches and indicator lights located on the control panel are described below.
1
3
2