Страница 1: ...SUPER USER S MANUAL Revision 1 0b SUPERSERVER 5015B MR...

Страница 2: ...ny such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits f...

Страница 3: ...st chapter provides a checklist of the main components included with the server system and describes the main features of the Super X7SBi motherboard and the SC512 200 chassis Chapter 2 Server Install...

Страница 4: ...chapter when adding or removing processors or main memory and when reconfiguring the motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC512 200 1U rackmo...

Страница 5: ...v Preface Notes...

Страница 6: ...tallation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 2 4 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Moun...

Страница 7: ...tallation Instructions 4 4 Circuit Breaker 4 5 Power Disconnection Warning 4 6 Equipment Installation 4 8 Restricted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13...

Страница 8: ...23 SuperDoctor III 5 24 5 14 Onboard Battery 5 26 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive Devices 6 1 Precautions 6 1 Unpacking 6 1 6 2 Control Panel 6 2 6 3 System Fans 6 3 System Fan F...

Страница 9: ...ainboard and chassis various hardware components may have been included with the 5015B MR as listed below One CPU heatsink SNK P0016P One 1 10 cm blower fan FAN 0059 One 1 air shroud MCP 310 00035 01...

Страница 10: ...ort for a six port 3 Gb sec Serial ATA subsystem which is RAID 0 1 5 and 10 sup ported The SATA drives are hot swappable units Note The operating system you use must have RAID support to enable the ho...

Страница 11: ...PORTS_0 7 FWH LPC I O MS KB FDD SER 1 SER 2 VRM 11 ADDR CTRL CTRL ADDR DATA DATA LPC PCI_32_BUS DDR2_667 800 DMI ATI ES1000 DIMM_CHA CK505 CLK MC H DIMM_CHB PCIE_x 8 GLAN1 82573V PCIE_x1 W83627DHG FS...

Страница 12: ...control panel on the SC512 200 provides important system monitoring and control information LEDs indicate power on network activity hard disk drive activity overheat warning and fan failure A main pow...

Страница 13: ...ress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Te...

Страница 14: ...1 6 SUPERSERVER 5015B MR User s Manual Notes...

Страница 15: ...on for the rack unit that will hold the SuperServer 5015B MR It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields...

Страница 16: ...e sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Server P...

Страница 17: ...omised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the...

Страница 18: ...t Installing with Rackmount Kit This section is only for customers that have the optional rack mount kit CSE PT8 Each of these assemblies consist of two sections an inner rail that secures to the chas...

Страница 19: ...ack Locking Tabs Both chassis rails have a locking tab which serves two functions The first is to lock the server into place when installed and pushed fully into the rack which is its normal position...

Страница 20: ...Figure 2 3 When the server has been pushed completely into the rack you should hear the locking tabs click Warning To prevent bodily injury when mounting or servicing this unit in a rack you must take...

Страница 21: ...ned to balance the weight between front and back If a bezel is included on your server remove it Then attach the two front brackets to each side of the chassis then the two rear brackets positioned wi...

Страница 22: ...ill need to open the unit to make sure the motherboard is properly installed and all the connections have been made Accessing the Inside of the System Figure 2 7 1 Grasp the two handles on either side...

Страница 23: ...inside of the server Checking the Components 1 You may have one processor already installed into the system board The processor should have its own heatsink attached See Chapter 5 for instruc tions on...

Страница 24: ...Bay Setup Next you should check to make sure the peripheral drives and the Serial ATA drive have been properly installed and all essential connections have been made Checking the Drives 1 For servicin...

Страница 25: ...Note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fan Providing Power 1 The last thing you must do is to provide input power to th...

Страница 26: ...2 12 SUPERSERVER 5015B MR User s Manual Notes...

Страница 27: ...explains the meanings of all LED indicators and the appropriate response you may need to take 3 2 Control Panel Buttons There are two push buttons located on the front of the chassis These are in ord...

Страница 28: ...may be caused by cables obstructing the airflow in the system or the ambient room tem perature being too warm Check the routing of the cables and make sure all fans are present and operating normally...

Страница 29: ...Chapter 3 System Interface 3 3 Power Indicates power is being supplied to the system s power supply units This LED should normally be illuminated when the system is operating...

Страница 30: ...3 4 SUPERSERVER 5015B MR User s Manual Notes...

Страница 31: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 32: ...onsidere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el...

Страница 33: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 34: ...en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher...

Страница 35: ...ert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes de...

Страница 36: ...ft um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the...

Страница 37: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 38: ...nung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o ut...

Страница 39: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 40: ...e or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een be...

Страница 41: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 42: ...ara fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprime...

Страница 43: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Страница 44: ...ctrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Backp...

Страница 45: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Страница 46: ...eguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous...

Страница 47: ...dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilat...

Страница 48: ...apter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle ande...

Страница 49: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Страница 50: ...4 20 SUPERSERVER 5015B MR User s Manual Notes...

Страница 51: ...handle them very carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally su...

Страница 52: ...the back lip of the top cover of the chassis then pull the cover off 2 The X7SBi requires a chassis big enough to support a 12 x 9 6 serverboard such as Supermicro s SC512 200 3 Make sure that the I...

Страница 53: ...page 5 11 for connector locations Control Panel cable JF1 SATA drive data cable SATA0 Important Make sure the the cables do not come into contact with the fans Connecting Power Cables The X7SBi has a...

Страница 54: ...colors and locations of the various I O ports Figure 5 1 Control Panel Header Pins Mouse Green Keyboard Purple COM1 Port Turquoise VGA Port Blue Figure 5 2 I O Ports NMI x Key Vcc Vcc Vcc Vcc Vcc Vcc...

Страница 55: ...heatsink Intel s boxed Xeon CPU package contains the CPU fan and heatsink assembly If you buy the CPUs separately use only Intel certified heatsinks and fans Make sure to install the heatsink backpla...

Страница 56: ...your thumb and your index finger to hold the CPU at opposite sides 4 Align pin1 of the CPU the corner marked with a triangle with the notched corner of the CPU socket 5 Find the corner of the CPU tha...

Страница 57: ...ur thumb to gently push the load lever down until it snaps into the retention clasp 9 If the CPU is properly installed into the socket the PnP cap will be automatically released from the load plate wh...

Страница 58: ...he CPU or the heatsink However if you do need to uninstall the heatsink please follow these instructions to avoid damaging the CPU or the CPU socket Installation and Removal of the Heatsink Uninstalli...

Страница 59: ...mation below 3 To enhance memory performance install pairs of memory modules of the same type and of the same beginning with DIMM 1A and DIMM 2A then DIMM 1B and DIMM 2B Notes Due to a chipset limitat...

Страница 60: ...h by using a screw to secure the top of the card shield to the chassis The PCI slot shield protects the serverboard and its components from EMI and aid in proper ventilation so make sure it is always...

Страница 61: ...Figure 5 4 X7SBi Layout not drawn to scale 5 8 Serverboard Details Notes Jumpers not indicated are for testing purposes only Slot 6 PCI Exp x8 and the PCI X slots are specially designed for Supermicro...

Страница 62: ...Connector F P USB6 7 F P USB8 9 Front Panel Accessible USB Headers IDE IDE HDD Connector JD1 Speaker Header JF1 Front Panel Connector JL1 Chassis Intrusion Header JLED Power LED Header JOH Overheat W...

Страница 63: ...8 COM 6 5V 19 COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 Ground Power Button Pin Definitions JF1 Pin D...

Страница 64: ...IC2 JLAN2 LED The LED connections for JLAN2 are on pins 9 and 10 of JF1 Attach an LED cable to display network activ ity See the table on the right for pin definitions NIC1 LED Pin Definitions JF1 Pin...

Страница 65: ...keyboard port See the table on the right for pin definitions NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 Refer to the table on the right for pin definition...

Страница 66: ...esignated LAN1 and LAN2 are located beside the VGA port on the I O backplane These ports accept RJ45 type cables Wake On Ring The Wake On Ring header is des ignated JWOR This function allows your comp...

Страница 67: ...o communicate with a system monitor ing chip on the backplane See the table on the right for pin definitions SGPIO Header Pin Definitions T SGPIO 1 T SGPIO 2 Pin Definition Pin Definition 1 NC 2 NC 3...

Страница 68: ...1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 F...

Страница 69: ...Watch Dog must also be en abled in BIOS Note When enabled the user needs to write their own application software in order to disable the Watch Dog Timer Watch Dog Jumper Settings JWD Jumper Setting D...

Страница 70: ...LED is located at LE1 This LED Indicator is lit when the system is on Be sure to unplug the power cable before removing or adding any components See the table on the right for more details Onboard Po...

Страница 71: ...Drive Select B 13 Ground 14 Drive Select B 15 Ground 16 Motor Enable 17 Ground 18 DIR 19 Ground 20 STEP 21 Ground 22 Write Data 23 Ground 24 Write Gate 25 Ground 26 Track 00 27 Ground 28 Write Protec...

Страница 72: ...pin definitions IDE Connector An IDE connector is included on the motherboard See the table on the right pin definitions IDE Drive Connectors Pin Definitions IDE Pin Definition Pin Definition 1 Reset...

Страница 73: ...site at http www supermicro com products Find the product page for your motherboard here where you may down load individual drivers and utilities After creating a CD DVD with the ISO files insert the...

Страница 74: ...perature system voltages and fan status See the figures below for examples of the SuperDoctor III interface Note The default User Name and Password for SuperDoctor III is ADMIN ADMIN Note When SuperDo...

Страница 75: ...rom our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download the SDIII User s Guide at http www supermicro com PRODUCT Manuals SDIII UserGuide pdf For Linux we will recom...

Страница 76: ...e regulations set up by your local hazardous waste management agency to dispose of your used battery properly Figure 5 8 Installing the Onboard Battery Please handle used batteries carefully Do not da...

Страница 77: ...ry carefully The following measures are generally sufficient to protect your equipment from ESD discharge Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded m...

Страница 78: ...together in a ribbon cable to simplify the connection Connect the cable from JF1 on the motherboard to the control panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both head...

Страница 79: ...nstalled and making a good seal in order for the cooling air to circulate properly through the chassis The fan can adjust its speed according to the heat level sensed in the system which results in mo...

Страница 80: ...ve the DVD ROM module drive 3 Remove the drive tray from the chassis 4 To add a new SATA drive install a drive into the tray with the printed circuit board side facing down and so that the mounting ho...

Страница 81: ...cover when finished Figure 6 5 Attaching the Side Rails and Backplane PCB Warning Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information on recomme...

Страница 82: ...il it locks you will hear a click 3 Depress the two buttons on the top of the chassis to release the top cover and push it away from you You can then lift the top cover from the chassis to gain full a...

Страница 83: ...stem parameters Each time the computer is powered on the computer is configured with the values stored in the CMOS logic by the system BIOS which gains control at boot up How To Change the Configurati...

Страница 84: ...s 1 By pressing Delete immediately after turning the system on or 2 When the message shown below appears briefly at the bottom of the screen during the POST Power On Self Test press the Delete key to...

Страница 85: ...Diskette A This setting allows the user to set the type of floppy disk drive installed as diskette A The options are Disabled 360Kb 5 25 in 1 2MB 5 25 in 720Kb 3 5 in 1 44 1 25MB 3 5 in and 2 88MB 3...

Страница 86: ...Adaptec HostRAID firmware The options are Intel and Adaptec SATA AHCI Select Enable to enable the function of Serial ATA Advanced Host Interface Take caution when using this function This feature is...

Страница 87: ...tem indicates the number of headers Sectors This item displays the number of sectors Maximum Capacity This item displays the maximum storage capacity in the CHS Format LBA Format The following items w...

Страница 88: ...eters of the IDE device installed on a slot Enter a number between 1 to 39 to select a predetermined IDE device Select User to allow the user to enter the parameters of the HDD installed Select CDROM...

Страница 89: ...the system 7 4 Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys Youshouldseethefollowingdisplay Theitemswithatrianglebesidethemhave sub menus that can b...

Страница 90: ...tem up from the S1 S4 or S5 state If this feature is set to Enabled you will also need to enable the JPWAKE jumper by closing pins 1 2 Please refer to Pg 1 5 and Chapter 2 for more details The default...

Страница 91: ...function of Machine Checking and allow the CPU to detect and report hardware machine errors via a set of model specific registers MSRs The options are Enabled and Disabled Compatible FPU Code Availab...

Страница 92: ...ffect Please refer to Intel s web site for detailed information No Execute Mode Memory Protection Available when supported by the CPU and the OS Set to Enabled to enable Execute Disable Bit and allow...

Страница 93: ...oducing periodic interrupts at a much higher frequency than a Real time Clock RTC can in synchronizing multimedia streams providing smooth playback and reducing the dependency on other timestamp calcu...

Страница 94: ...e CPU to speed up CPU operations Select Uncached to disable this function Select Write Through to allow data to be cached into the buffer and written into the system memory at the same time Select Wri...

Страница 95: ...to the following settings for PCI devices PCI 32 Slot Access the submenu for each of the settings above to make changes to the following Option ROM Scan When enabled this setting will initialize the...

Страница 96: ...ew software you might want to change this setting and try again A different OS requires a different Bus Master clock rate PCI Exp x8 Slot Access the submenu for each of the settings above to make chan...

Страница 97: ...tallation of a new software you might want to change this setting and try again A different OS requires a different Bus Master clock rate I O Device Configuration Access the submenu to make changes to...

Страница 98: ...options are Enabled user defined Disabled and Auto BIOS or OS controlled Base I O Address Select the base I O address for the parallel port The options are 378 278 and 3BC Interrupt This setting allo...

Страница 99: ...play to inform you of the event log capacity It is not a setting View DMI Event Log Highlight this item and press Enter to view the contents of the event log Event Logging This setting allows you to E...

Страница 100: ...400 9600 19 2K 38 4K 57 6K and 115 2K Console Type This item allows you to set the console redirection type The options are VT100 VT100 8bit PC ANSI 7bit PC ANSI VT100 VT UTF8 and ASCII Flow Control T...

Страница 101: ...led by Pulse Width Modulation PWM Select 3 pin if your chassis came with 3 pin fan headers Select 4 pin if your chassis came with 4 pin fan headers Select Workstation if your system is used as a Works...

Страница 102: ...stem interface The options are Enabled and Disabled Clear System Event Logging Enabling this function to force the BIOS to clear the system event logs during the next cold boot The options are Enabled...

Страница 103: ...on when OS Boot Watch Dog is set to Disabled Time Out Option This feature allows the user to determine what action to take in an event of a system boot failure The options are No Action Reset Power Of...

Страница 104: ...7 22 SUPERSERVER 5015B MR User s Manual Realtime Sensor Data This feature display information from motherboard sensors such as temperatures fan speeds and voltages of various components...

Страница 105: ...password has been entered for the system User Password Is This item indicates if a user password has been entered for the system Clear means such a password has not been used and Set means a user pass...

Страница 106: ...e the feature of Write Protect to protect the boot sector on the hard drives from virus intrusion Password on Boot When set to Enabled a user will need to key in a password to enter the system at syst...

Страница 107: ...or the devices included in the candidate list above are currently disabled Use a key or a key to move the device up or down Use the f key or the r key to specify the type of an USB device either fixed...

Страница 108: ...lity Exit Discarding Changes Highlight this item and hit Enter to exit the BIOS Setup utility without saving any changes you may have made Load Setup Defaults Highlight this item and hit Enter to load...

Страница 109: ...eyboard controller failed test May require replacing keyboard controller Keyboard locked Unlock key switch Unlock the system to proceed Monitor type does not match CMOS Run SETUP Monitor type not corr...

Страница 110: ...ious POST did not complete successfully POST loads default values and offers to run Setup If the failure was caused by incorrect values and they are not corrected the next boot will likely fail On sys...

Страница 111: ...sters Software NMI Failed ServerBIOS2 test error Cannot generate software NMI Non Maskable Interrupt Fail Safe Timer NMI Failed ServerBIOS2 test error Fail Safe Timer takes too long Device Address Con...

Страница 112: ...sfully tested nnnn kB System RAM Passed Where nnnn is the amount of system RAM in kilobytes successfully tested One or more I2O Block Storage Devices were excluded from the Setup Boot Menu There was n...

Страница 113: ...Write down and follow the information shown on the screen Press F2 to enter Setup Optional message displayed during POST Can be turned off in Setup PS 2 Mouse PS 2 mouse identified Run the I2O Configu...

Страница 114: ...A 6 SUPERSERVER 5015B MR User s Manual Notes...

Страница 115: ...ll write the error to port 80h attempt to initialize video and write the error in the top left corner of the screen The following is a list of codes that may be written to port 80h POST Code Descripti...

Страница 116: ...Shadow system BIOS ROM 3Ah Auto size cache 3Ch Advanced configuration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize extended memory for RomPilot 42h Initialize int...

Страница 117: ...80h Disable onboard Super I O ports and IRQs 81h Late POST device initialization 82h Detect and install external RS232 ports 83h Configure non MCD IDE controllers 84h Detect and install external para...

Страница 118: ...te QuietBoot optional B6h Check password optional B7h Initialize ACPI BIOS B9h Prepare Boot BAh Initialize SMBIOS BBh Initialize PnP Option ROMs BCh Clear parity checkers BDh Display MultiBoot menu BE...

Страница 119: ...Eh Shadow Boot Block EFh System memory test F0h Initialize interrupt vectors F1h Initialize Run Time Clock F2h Initialize video F3h Initialize System Management Manager F4h Output one beep F5h Clear H...

Страница 120: ...B 6 SUPERSERVER 5015B MR User s Manual Notes...

Страница 121: ...hoenix Flash ROM Memory Capacity Four 240 pin DIMM slots that can support up to 8 GB of unbuffered ECC DDR2 800 667 SDRAM Note See the memory section in Chapter 5 for details SATA Controller On chip I...

Страница 122: ...mperature 40 to 70 C 40 to 158 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A E...

Страница 123: ...orm be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such pro...

Страница 124: ...C 4 SUPERSERVER 5015B MR User s Manual Notes...