SuperBlade Server SBI-610P-1(C/T)2N User's Manual
14
Removing a Blade Unit from the Enclosure
A blade can be removed from the enclosure while other blades continue to operate.
Note:
When a blade is removed, please ensure the slot is covered with a dummy blade/
chassis to ensure the neighboring blade does not overheat.
Removing a Blade Unit from the Enclosure
1.
Power down the blade unit.
2. Push down on the locking latch and pull the locking lever away from the center of the
blade until the blade unlocks from the enclosure.
3.
Use the locking levers to pull the blade from the enclosure.
Figure 2-1. Blade Locking Levers
2.2 Installing or Removing the Blade Unit
Installing a Blade Unit into the Enclosure
1.
Hold the larger locking lever open and slide the blade fully into its bay.
2. As the blade is seated in the enclosure, push the larger lever into its locked position.
The blade will slightly slide towards the back of the enclosure as the latches lock into
position.
Locking Lever
Locking Latch
Caution
: Insert the blade carefully so
the rear connectors are not damaged.