Страница 1: ...USER S MANUAL Revision 1 0 SuperBlade SBA 4114S C2N SBA 4114S T2N...

Страница 2: ...lass A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...

Страница 3: ...rs and utilities https www supermicro com wdl Product safety info https www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support su...

Страница 4: ...ng the Blade Unit 17 Installing a Blade Unit into the Enclosure 17 Removing a Blade Unit from the Enclosure 17 2 3 Powering Up or Down 18 Powering Up a Blade Unit 18 Powering Down a Blade Unit 18 2 4...

Страница 5: ...r 5 48 4 4 BMC 49 BMC ADMIN User Password 49 Chapter 5 Optional Components 5 1 TPM Security Module 50 Chapter 6 Troubleshooting and Support 6 1 Information Resources 51 Website 51 Direct Links for the...

Страница 6: ...6 8 BMC Reset 63 6 9 Where to Get Replacement Components 64 6 10 Reporting an Issue 64 Technical Support Procedures 64 Returning Merchandise for Service 64 Vendor Support Filing System 65 6 11Feedback...

Страница 7: ...EPYC 7003 7002 Series in SP3 socket 7003 processor drop in support requires BIOS version 2 0 or newer Memory Eight DIMM slots 2TB 3DS ECC RDIMM LRDIMM DDR4 up to 3200MHz Storage Two 2 5 hot swap hybri...

Страница 8: ...rs Item Description Control Panel Power button and status indicators AIOMs Two AIOM slots for input output Latch Lever Secures the blade into the enclosure Storage Drives Two 2 5 hybrid drive bays NVM...

Страница 9: ...table below For OS RAID or non RAID configurations some LED indications are not supported such as hot spare Drive Carrier LED Indicators Color Blinking Pattern Behavior for Device Activity LED Blue So...

Страница 10: ...icates that KVM has been initialized Blue flashing slowly Unit Identifier indicator The UID function is activated with a management program Blue flashing quickly Firmware revision NIC LED Green flashi...

Страница 11: ...11 Chapter 1 Introduction Top View Figure 1 4 System Top View Memory AIOMs CPU Drives Mezzanine M 2 Slots...

Страница 12: ...ture Description Mezzanine Add on card CPU Processor and heatsink Memory DIMM slots under air shrouds M 2 Slots Two slots for M 2 SSDs AIOMs Slots for two Advanced Input Output modules Drives Two 2 5...

Страница 13: ...ptions For detailed descriptions pinout information and jumper settings refer to Chapter 3 or the Motherboard Manual Figure 1 7 Motherboard Layout 2X PCIe GEN 4 Connectors JPWR1 DIMMA1 BMC LAN MB PWR...

Страница 14: ...PLD header JKVM1 Connector for external keyboard video and mouse JFP1 Front control panel connector for LED and Power Button BMCLAN BMC LAN port JTPM1 Trusted Platform Module TPM Port 80 connector 2x...

Страница 15: ...B H G F D AMD SP3 G0 G1 G2 G3 Mezzanine slot PCIE X16 G1 0 15 G2 18 15 CX4 25G LAN P0 P1 P2 P3 P0 0 3 P1 0 15 P2 0 15 M 2 PCIE X4 SATA M 2 PCIE X4 SATA P0 4 7 PCIE X16 PCIE cable connector PCIE X16 B...

Страница 16: ...s and Linux operating systems may be mixed together in the same blade enclosure 2 1 Unpacking the System Inspect the box the system was shipped in and note if it was damaged in any way If any equipmen...

Страница 17: ...ving a Blade Unit from the Enclosure 1 Power down the blade unit 2 Pull open the latch lever and use it to pull the blade from the enclosure Figure 2 1 Blade Latch Lever 2 2 Installing or Removing the...

Страница 18: ...of the onboard BMC chip in the blade module Powering Down a Blade Unit A blade unit may be powered down in any of the following ways Press the power button on the blade unit Use IPMIView or the browse...

Страница 19: ...Setup 2 4 Removing the Cover When the blade has been removed from the enclosure the top cover can be removed to access the components Remove the screw and slide the cover toward the rear and off Figu...

Страница 20: ...mage components Assemble the processor CPU and heatsink together first then install that assembly onto the CPU socket Notes The motherboard should be installed into the chassis first and the processor...

Страница 21: ...as described in Section 2 3 1 Use a Torx T20 driver to loosen the screws holding down Force Frame in the sequence of 3 2 1 The screws are numbered on the Force Frame next to each screw hole Tighten to...

Страница 22: ...up by gripping the lift tabs near the front end of the rail frame While keeping a secure grip of the Rail Frame lift it to a position so you can do the next step of removing the External Cap Note The...

Страница 23: ...ly from its shipping tray and while gripping the handle align the flanges of the Carrier Frame onto the rails of the Rail Frame so its pins will be at the bottom when the Rail Frame is lowered later 6...

Страница 24: ...s marked Remove at the middle of the cap and pull vertically upwards to remove the PnP Cover Cap Caution The exposed socket contacts are extremely vulnerable and can be damaged easily Do not touch or...

Страница 25: ...16 1 kgf cm 14 lbf in of torque The Force Frame secures both the Rail Frame and CPU Package Caution Tightening must be executed in proper 1 2 3 sequence to avoid causing catastrophic damage to the soc...

Страница 26: ...driver in a diagonal pattern as below tighten the four heatsink screws halfway and then tighten them evenly to 16 1 kgf cm 14 0 lbf in of torque The processor and heatsink installation is complete Rep...

Страница 27: ...w and remove the heatsink screws from the motherboard in the sequence as show in the figure above 2 Hold and gently pivot the heatsink back and forth to loosen it from the CPU Do not use excessive for...

Страница 28: ...Channels 8 Channels RDIMM 1R 32GB 128GB 256GB 3200 2R 64GB 256GB 512GB LRDIMM 4R 128GB 512GB 1TB 2S4R 256GB 1TB 2TB LRDIMM 3Ds 2S2R 4 Ranks 128GB 512GB 1TB 2S4R 8 Ranks 256GB 1TB 2TB Memory Guidelines...

Страница 29: ...t channels are supported but not recommended J19 H12SSW iN MEGERAC LICENSE MAC CODE BAR CODE MH15 JF1 LED11 JWD1 JUART2 HDT1 JVRM1 JSLIM3 B1 JSLIM2 JSLIM1 FAN6 FAN5 FAN4 FAN3 FAN2 FAN1 JL1 JPWR2 JPWR1...

Страница 30: ...om the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release Tabs 2 Al...

Страница 31: ...the Battery When the blade has been removed from the enclosure and the top cover removed 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of t...

Страница 32: ...lling Drives Figure 2 15 Logical Drive Numbers 1 2 2 8 Storage Drives The blade has two 2 5 hot swap storage drive bays The drives are mounted in tool less drive carriers that simplify their removal f...

Страница 33: ...g a Hot Swap Drive Carrier from the Chassis 1 Press the release button on the drive carrier which will extend the drive carrier handle 2 Use the drive carrier handle to pull the drive out of the chass...

Страница 34: ...onnector end toward the rear of the carrier 3 Tilt the drive to insert it onto the two posts on the right inside of the carrier 4 Pull out the two spring locking clasps to allow the drive to sit fully...

Страница 35: ...hboard Server Health NVMe SSD 2 Select Device Group and Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorized by...

Страница 36: ...es of all NVMe drives BMC Dashboard Server Health Sensor Reading NVME_SSD Shows the single highest temperature among all the NVMe drives M 2 Solid State Drives Up to two M 2 solid state drives SSDs ca...

Страница 37: ...9 AIOMs The system supports two advanced input output modules AIOMs Installing an AIOM 1 Pull up the locking latch 2 Insert the cards in to the slot 3 Push the latch down to secure the modules Figure...

Страница 38: ...ds 2 10 System Cooling Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency These do not require screws to install Installing the Air Shrouds Position the air shrouds as illustrated...

Страница 39: ...rough the chassis Pull all excess cabling out of the airflow path or use shorter cables The control panel LEDs display system heat status See Control Panel in Chapter 1 for details Overheating There a...

Страница 40: ...pin Power Connector Pin Definitions Pins Definition 1 through 4 Ground 5 through 8 12V TPM Header The JTPM1 header is used to connect a Trusted Platform Module TPM Port 80 which is available from Sup...

Страница 41: ...E Gen 4 x4 or 2 SATA support C Front panel control connector LED and power button D PCIE Gen 4 x16 Mezzanine card connector E Keyboard video mouse port F BMC and on board LAN connector to enclosure mi...

Страница 42: ...g to reset the system if an application hangs Jumping pins 2 3 will generate a non maskable interrupt signal for the application that hangs Watch Dog must also be enabled in BIOS The default setting i...

Страница 43: ...LED is illuminated the system is turned on and all the system power rails are ready When the system is turned off or any one of the system power rails fails this LED will turn off Onboard Power LED In...

Страница 44: ...ves installed and no bootable devices attached to it Once these conditions are met make sure the PXE server is running Then turn on the blade on which you wish to install the OS The BIOS in the blade...

Страница 45: ...Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive or the BMC KVM console 2 Boot from a bootable device with Windows OS installation Y...

Страница 46: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...

Страница 47: ...d Another option is to go to the Supermicro website at www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or di...

Страница 48: ...etwork Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SS...

Страница 49: ...our website at www supermicro com en solutions management software bmc resources BMC ADMIN User Password For security each system is assigned a unique default BMC password for the ADMIN user This can...

Страница 50: ...ineon 9670 controller Horizontal form factor The JTPM1 header is used to connect a Trusted Platform Module TPM A TPM is a security device that supports encryption and authentication in hard drives It...

Страница 51: ...option offers downloads manuals BIOS BMC drivers etc FAQs RMA warranty and other service extensions Direct Links for the SBA 4114S C2N T2N System Web SBA 4114S C2N T2N specifications page BH12SSi M25...

Страница 52: ...recent security notices Supermicro Phone and Addresses Direct Links continued 6 2 BMC Interface The system supports a Baseboard Management Controller BMC interface It provides remote access monitorin...

Страница 53: ...Make sure that no short circuits exist between the motherboard and chassis 5 Disconnect all cables from the motherboard including those for the keyboard and mouse 6 Remove all add on cards 7 Install a...

Страница 54: ...commended that you use the same memory type and speed for all DIMMs in the system See Section 3 3 for memory details 3 Check for bad DIMM modules or slots by swapping modules between slots and noting...

Страница 55: ...before or during OS installation check the following 1 Source of installation Make sure that the devices used for installation are working properly including boot devices such as CD 2 Cable connectio...

Страница 56: ...nding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No memory de...

Страница 57: ...ou can download a crash dump of status information using the BMC Dashboard The BMC manual is available at www supermicro com manuals other BMC_Users_Guide_X12_H12 pdf Check Error Log 1 Access the BMC...

Страница 58: ...ed When the system power is turned on the recovery block codes execute first Once this process is complete the main BIOS code will continue with system initialization and the remaining POST Power On S...

Страница 59: ...e BIOS binary image into a USB flash device and rename it Super ROM for the BIOS recovery use Note 2 Before recovering the main BIOS image confirm that the Super ROM binary image file you download is...

Страница 60: ...shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt...

Страница 61: ...EFI Shell prompt appears type fs to change the device directory path Go to the directory that contains the BIOS package you extracted earlier from Step 6 Enter flash nsh BIOSname at the prompt to star...

Страница 62: ...complete When you see the screen above unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously...

Страница 63: ...e system Notes Clearing CMOS will also clear all passwords Do not use the PW_ON connector to clear CMOS JBT1 contact pads 6 8 BMC Reset The BMC can be reset using the UID button Reset Press and hold t...

Страница 64: ...boot block code 3 If you still cannot resolve the problem include the following information when contacting us for technical support System motherboard and chassis model numbers and PCB revision numb...

Страница 65: ...lure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems Vendor Support Filing System For issues r...

Страница 66: ...om Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support sup...

Страница 67: ...of the 64k block at which the error was detected System RAM Failed at offset nnnn System RAM failed at offset nnnn of in the 64k block at which the error was detected Extended RAM Failed at offset nnn...

Страница 68: ...RAM cache failed and BIOS disabled the cache On older boards check the cache jumpers You may have to replace the cache See your dealer A disabled cache slows system performance considerably CPU ID CP...

Страница 69: ...s it displays Press F1 to resume F2 to Setup F3 for previous Displayed after any recoverable error message Press F1 to start the boot process or F2 to enter Setup and change the settings Press F3 to d...

Страница 70: ...M 08h Initialize chipset with initial POST values 09h Set IN POST flag 0Ah Initialize CPU registers 0Bh Enable CPU cache 0Ch Initialize caches to initial POST values 0Eh Initialize I O component 0Fh I...

Страница 71: ...3Ch Advanced configuration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize extended memory for RomPilot 42h Initialize interrupt vectors 45h POST device initializatio...

Страница 72: ...t Mode SMM area 6Ah Display external L2 cache size 6Bh Load custom defaults optional 6Ch Display shadow area message 6Eh Display possible high address for UMB recovery 70h Display error messages 72h C...

Страница 73: ...rs 92h Jump to UserPatch2 93h Build MPTABLE for multi processor boards 95h Install CD ROM for boot 96h Clear huge ES segment register 98h 1 2 Search for option ROMs One long two short beeps on check s...

Страница 74: ...ders C0h Try to boot with INT 19 C1h Initialize POST Error Manager PEM C2h Initialize error logging C3h Initialize error display function C4h Initialize system error handler C5h PnPnd dual CMOS option...

Страница 75: ...Initialize the CPU E3h Initialize system timer E4h Initialize system I O E5h Check force recovery boot E6h Checksum BIOS ROM E7h Go to BIOS E8h Set Huge Segment E9h Initialize Multi Processor EAh Init...

Страница 76: ...or it displays an additional word bitmap xxxx indicating the address line or bits that failed For example 2C 0002 means address line 1 bit one set has failed 2E 1020 means data bits 12 and 5 bits 12 a...

Страница 77: ...sistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These war...

Страница 78: ...idere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el te...

Страница 79: ...ient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het e...

Страница 80: ...n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het systeem o...

Страница 81: ...el edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l installat...

Страница 82: ...a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre...

Страница 83: ...chuwing Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of verwijderen van systeem onderdelen dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voed...

Страница 84: ...lte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention Il est vivement recommand de confier...

Страница 85: ...de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s une zo...

Страница 86: ...verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling Warning There is the danger of explosion if the battery is replaced in...

Страница 87: ...ichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplac e correctement Ne...

Страница 88: ...dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el...

Страница 89: ...dous voltage or energy is present on the backplane when the system is operating Use caution when servicing Waarschuwing Deze eenheid kan meer dan n stroomtoevoeraansluiting bevatten Alle aansluitingen...

Страница 90: ...g Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del pla...

Страница 91: ...Electrical Codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales A...

Страница 92: ...regulations Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement sou...

Страница 93: ...hasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possibl...

Страница 94: ...l Safety Law prohibits the use of UL or CSA certified cables that have UL CSA shown on the cord for any other electrical devices than products designated by Supermicro only Waarschuwing Gevaarlijk bew...

Страница 95: ...ln und oder Adapater die Ihre rtlichen Sicherheitsstandards einhalten Der Gebrauch von anderen Kabeln und Adapter k nnen Fehlfunktionen oder Feuer verursachen Die Richtlinien untersagen das Nutzen von...

Страница 96: ...oldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing of brand veroorzaken Wetgeving vo...

Страница 97: ...hybrid front drive bays SBA 4114S C2N NVME SAS SATA SBA 4114S T2N NVMe SATA Two M 2 PCIe x4 Input Output Two AIOMs Two 25 GbE onboard Motherboard BH12SSi M25 6 3 x 11 160 mm x 279 mm Chassis MCP 680 4...

Страница 98: ...EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 8 BS EN 61000 4 11 Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Product Safety 2014 35 EU LVD...