Chapter 41: CFM Commands
– 1275 –
suppress alarms since the received AIS information does not contain
that information. Therefore, upon reception of a frame with AIS
information, the MEP will suppress alarms for all peer MEPs whether
there is still connectivity or not.
•
However, for a point-to-point connection, a MEP has only a single peer
MEP for which to suppress alarms when it receives frames with AIS
information.
•
If suppression is enabled by this command, upon receiving a frame with
AIS information, a MEP detects an AIS condition and suppresses loss of
continuity alarms associated with all its peer MEPs. A MEP resumes loss
of continuity alarm generation upon detecting loss of continuity defect
conditions in the absence of AIS messages.
E
XAMPLE
This example suppresses sending frames with AIS information.
Console(config)#ethernet cfm ais suppress alarm md voip ma rd
Console(config)#
ethernet cfm
domain
This command defines a CFM maintenance domain, sets the authorized
maintenance level, and enters CFM configuration mode. Use the
no
form to
delete a CFM maintenance domain.
S
YNTAX
ethernet cfm domain index
index
name
domain-name
level
level-id
[
mip-creation
type
]
no ethernet cfm domain index index
index –
Domain index. (Range: 1-65535)
domain-name –
Domain name. (Range: 1-43 alphanumeric
characters)
level-id
– Authorized maintenance level for this domain.
(Range: 0-7)
type
– Specifies the CFM protocol’s creation method for
maintenance intermediate points (MIPs) in this domain:
default
– MIPs can be created for any maintenance association
(MA) configured in this domain on any bridge port through
which the MA’s VID can pass.
explicit
– MIPs can be created for any MA configured in this
domain only on bridge ports through which the MA’s VID can
pass, and only if a maintenance end point (MEP) is created at
some lower MA Level.
none
– No MIP can be created for any MA configured in this
domain.
Содержание SSE-G2252
Страница 42: ...44 General IP Routing on page 627...
Страница 174: ...Chapter 6 VLAN Configuration Configuring VLAN Mirroring 178 Figure 6 27 Showing the VLANs to Mirror...
Страница 511: ...Chapter 14 Basic Administration Protocols UDLD Configuration 518 Figure 14 100 Displaying UDLD Neighbor Information...
Страница 603: ...Chapter 16 IP Configuration Setting the Switch s IP Address IP Version 6 609...
Страница 883: ...Chapter 24 General Security Measures Port based Traffic Segmentation 894...
Страница 989: ...Chapter 30 Congestion Control Commands Automatic Traffic Control Commands 1000 Console...
Страница 1007: ...Chapter 33 Address Table Commands 1019...
Страница 1137: ...Chapter 38 Quality of Service Commands 1150...
Страница 1366: ...Chapter 46 IP Routing Commands Global Routing Configuration 1381 Connected 2 Total 2 FIB 0 Console...