Chapter 2: Server Installation
25
Note:
The figure is for illustrative purposes only. Always install servers to the bottom of a
rack first.
Ball-Bearing
Shuttle
Figure 2-6. Installing the Server into a Rack
Standard Chassis Installation
Installing the Chassis into a Rack
1.
Confirm that the inner rails are properly installed on the chassis.
2.
Confirm that the outer rails are properly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the ball-
bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure even on
both sides, until the locking tab of the inner rail clicks into the front of the middle rail,
locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis all the
way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles to the front
of the rack.