background image

S

UPER 

S

TORAGE 

S

YSTEM

 

 

6048R-E1CR36N

USER’S MANUAL

 

 

1.0a

Содержание 6048R-E1CR36N

Страница 1: ...SUPER STORAGE SYSTEM 6048R E1CR36N USER S MANUAL 1 0a ...

Страница 2: ... said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING R...

Страница 3: ...uring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC847BE1C R1K28LPB chassis You should follow the procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides deta...

Страница 4: ...ling the Outer Rails on the Rack 2 7 vii Chapter 3 System Interface 3 1 Overview 3 1 3 2 Control Panel Buttons 3 1 Reset 3 1 Power 3 1 3 3 Control Panel LEDs 3 2 Power Fail 3 2 Overheat Fan Fail 3 2 NIC1 3 2 NIC2 3 3 HDD 3 3 Power 3 3 3 4 Drive Carrier LEDs 3 4 Chapter 4 Standardized Warning Statements for AC Systems 4 1 About Standardized Warning Statements 4 1 Warning Definition 4 1 Installation...

Страница 5: ...stem Fans 6 4 System Fan Failure 6 4 Replacing System Fans 6 4 6 5 Drive Bay Installation Removal 6 5 Accessing the Drive Bays 6 5 Hard Drive Installation 6 6 Hard Drive Backplane 6 7 Removing the Air Shroud 6 8 6 6 Installing Optional Fixed Hard Drives 6 9 6 7 Power Supply 6 10 Power Supply Failure 6 10 DC Power 6 11 6 8 Attaching a JBOD Expansion Chassis 6 11 Chapter 7 BIOS 7 1 Introduction 7 1 ...

Страница 6: ...Notes SUPERSTORAGESYSTEM 6048R E1CR36N User s Manual x ...

Страница 7: ...wo 8 cm rear exhaust fans FAN 0125L4 One air shroud MCP 310 49004 0N Hardware RAID controller AOC S3108L H8IR JBOD expansion port AOM SAS3 8I8E LP SAS SATA Accessories One SAS SATA backplane BPN SAS3 846EL1 Thirty six 3 5 drive carriers MCP 220 00075 0B One set of mounting rails MCP 290 00057 0N Note For your system to work properly please follow the links below to download all necessary drivers u...

Страница 8: ... This means one PCI E 3 0 x16 and three PCI E 3 0 x8 slots are available for add on cards Rear I O Ports The I O ports include one COM port a VGA port four USB two USB 3 0 and two USB 2 0 four 10G TLAN Ethernet ports and a dedicated IPMI LAN port 1 3 Server Chassis Features The SC847BE1C R1K28LPB is a 4U form factor chassis designed to be used in a storage configuration The following is a general ...

Страница 9: ...pport supermicro com tw Website www supermicro com tw Figure 1 1 Intel C612 Chipset System Block Diagram Note This is a general block diagram Please see Chapter 5 for details P0 P0 P1 P1 D D E E E F F F G G G H H H PCI E x16 SLOT 3 PCI E SATA 1 SATA 2 DDR4 DIMM SATA 3 SATA 4 SATA 5 SATA 6 USB 3 0 SATA DDR4 DIMM 3 2 1 DDR4 DIMM G A LPC USB 3 0 LAN I350 X540 SAGEVILL A B D B C PROCESSOR1 A C PROCESS...

Страница 10: ...1 6 SUPERSTORAGESYSTEM 6048R E1CR36N User s Manual Notes ...

Страница 11: ...a suitable location for the rack unit that will hold the 6048R E1CR36N It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Read the Rack and Server Precau tions in the next section 2 3 Preparing for Setup The box the 6048R E1CR36N was shippe...

Страница 12: ...rature If installed in a closed or multi unit rack assembly the ambient operating tempera ture of the rack environment may be greater than the room s ambient temperature Therefore consideration should be given to installing the equipment in an environ ment compatible with the manufacturer s maximum rated ambient temperature Tmra Reduced Airflow Equipment should be mounted into a rack so that the a...

Страница 13: ...igning the hooks of the chas sis with the inner rail holes Make sure that the rail faces outward so that it will fit with the rack s mounting bracket 2 Slide the rail toward the front of the chassis Figure 2 1 Identifying the Different Rail Sections Inner Rail Rail Assembly Shown with Rails Retracted This Side Faces Outward Locking Tab Middle Rail Outer Rail Figure 2 2 Extending and Releasing the ...

Страница 14: ...l 3 Slide the inner rail forward toward the front of the chassis until the rail clicks into the locked position which secures the inner rail to the chassis 4 Secure the inner rail to the chassis with the screws provided 5 Repeat steps 1 through 4 above for the other inner rail Note chassis pictured may vary slightly from the 6048R E1CR36N system chassis 1 3 1 4 1 2 Inner Rails Installing the Outer...

Страница 15: ...ways install servers into racks from the bottom up The chassis pictured may vary slightly from the 6048R E1CR36N system chassis Stability hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip over ...

Страница 16: ... the chassis control panel 3 2 Control Panel Buttons The two push buttons located on the front of the chassis are in order from left to right a reset button and a power on off button Reset Use the reset button to reboot the system Power This is the main power button which is used to apply or turn off the main system power Turning off system power with this button removes the main power but keeps s...

Страница 17: ...indicates a fan failure When red continuously it indicates an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to make sure that the chassis covers are installed Finally verify that the heatsinks are ins...

Страница 18: ... Status Activity LED Blue Solid On SAS drive installed Blue Blinking I O activity Blue Dark off Sata drive installed or empty run I O to verify Status LED Red Solid On Failed drive for SAS SATA Red Blinking at 1 Hz Rebuild drive for SAS SATA Red Blinking with two blinks and one stop at 1 Hz Hot spare for SAS SATA Red On for five seconds then off Power on for SAS SATA Red Blinking at 4 Hz Identify ...

Страница 19: ... configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preve...

Страница 20: ...dures couramment utilisées pour éviter les accidents Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil référez vous au numéro de l instruction situé à la fin de chaque avertissement CONSERVEZ CES INFORMATIONS 안전을 위한 주의사항 경고 이 경고 기호는 위험이 있음을 알려 줍니다 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다 모든 장비에 대한 작업을 수행하기 전에 전기회로와...

Страница 21: ...systeem op de voedingsbron aansluit サーキッ ト ブレーカー この製品は 短絡 過電流 保護装置がある建物での設置を前提としています 保護装置の定格が250 V 20 Aを超えないこ とを確認下さい Warnung Dieses Produkt ist darauf angewiesen dass im Gebäude ein Kurzschluss bzw Überstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A beträgt Advertencia Este equipo utiliza el sistema de protección contra cortocircuit...

Страница 22: ...roleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V 20A Advertencia El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le système doit être débranché de toutes les sources de puissance ain...

Страница 23: ...ntés אזהרה רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת או הציוד والمدربيه و لتزكيب استبدال أو خدمة الجهاس هذا يسمح أن يجب فقط المؤهليه للمىظفيه 경고 훈련을 받고 공인된 기술자만이 이 장비의 설치 교체 또는 서비스를 수행할 수 있습니다 Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Warnung Diese Einheit ist zur Installation in Bereichen mit bes...

Страница 24: ... ٍ ف نتركُبها مناطق محظورة تم انىص َمكن ً إن ىل منطقت محظورة فقط استخذاو خالل من خاصت أداة أو ٌ أ نال أخري وسُهت مألما ومفتاح قفم 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van sp...

Страница 25: ...Cuando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Redundant P...

Страница 26: ...יים החשמל לחוקי תואמת להיות חייבת הציוד المعدات تركيب الكهربائية لل يمتثل أن يجب قىاويه والىطىية المحلية المتعلقة بالكهرباء 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud האחורי בפנל מתח אז הרה במהלך להיזהר יש המערכת ...

Страница 27: ...vertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur du châssis Prenez garde à ce que doigts tournevis et autres objets soient éloigné...

Страница 28: ...s que tienen UL o CSA se muestra en el código de otros dispositivos eléctricos que los productos designados por Supermicro solamente 電源コードとACアダプター 製品を設置する場合 提供または指定された接続ケーブル 電源コードとACアダプター を使用下さい 他のケーブルやアダプタを使用すると故障や火災の原因になるこ とがあ り ます 電気用品安全法は ULまたはCSA認定のケーブル UL CSEマークがコードに表 記 を Supermicroが指定する製品以外に使用するこ とを禁止しています ומתא חשמליים מ י AC אזהרה ומתאמים ספקים בכבלים להשתמש יש המוצר את מתקינים כאשר AC אשר...

Страница 29: ...4 20 SUPERSTORAGESYSTEM 6048R E1CR36N User s Manual Notes ...

Страница 30: ...fully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent Electrostatic Discharge ESD Touch a grounded metal object before removing any board from its anti...

Страница 31: ...y See Section 5 9 for power connector pin definitions Connecting the Control Panel JF1 contains header pins for various front control panel connectors See Figure 5 1 for the pin locations of the various front control panel buttons and LED indicators All JF1 wires have been bundled into a single cable to simplify this connection Make sure the red wire plugs into pin 1 as marked on the board The oth...

Страница 32: ...When receiving a serverboard without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise contact your retailer immediately Refer to the Supermicro web site for updates on CPU support OPEN1st WARNING OPEN1st WARNING Press down on the lever labeled Close 1st Pull lever away from the socket Gently push down to pop the load pla...

Страница 33: ...nt has already been applied 2 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the serverboard and the heatsink bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws until just snug do not over tighten the screws to avoid possible damage to the CPU 4 Finish the installation by fully tightening all four screws Figure 5 3 Installin...

Страница 34: ...ing Memory Modules CPU Corresponding DIMM Modules CPU1 P1 DIMMA1 P1 DIMMD3 P1 DIMM A1 B1 C1 D1 A2 B2 C2 D2 A3 B3 C3 D3 CPU2 P2 DIMME1 P1 DIMMH3 P2 DIMM E1 F1 G1 H1 E2 F2 G2 H2 E3 F3 G3 H3 Processor and Memory Module Population for Optimal Performance Number of CPUs DIMMs CPU and Memory Population Configuration Table For memory to work properly please follow the instructions below 1 CPU 2 DIMMs CPU...

Страница 35: ...E 3 0 X16 CPU2 SLOT4 PCI E 2 0 X4 IN X8 JL1 S SATA0 CPU1 SLOT3 PCI E 3 0 X16 S SATA1 S SATA2 CPU2 SLOT2 PCI E 3 0 X8 S SATA3 I SATA0 I SATA3 I SATA4 I SATA1 CPU2 SLOT1 PCI E 3 0 X8 COM2 I SATA5 UID VGA LAN3 4 LAN1 2 IPMI_LAN COM1 CPU2 CPU1 P2 DIMME1 P2 DIMMG1 I SATA2 JI2C1 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st USB 6 3 0 BIOS USB2 3 S SGPIO1 X10DRC i LN4 T4 Rev 1 01 BMC LAN CTRL LSI 3108 SAS CTRL I...

Страница 36: ... Module Port 80 Header JUIDB1 UID Unit Identification Button IPMI LAN Dedicated IPMI LAN support by the ASpeed controller I SATA 0 5 SATA 3 0 Ports supported by Intel PCH I SATA 0 5 S SATA 0 3 SATA 3 0 Ports supported by Intel SCU S SATA 0 3 SAS 0 3 4 7 SAS 3 0 Ports supported by the LSI 3108 controller Slot1 PCI Express 3 0 x8 Slot from CPU2 Slot2 PCI Express 3 0 x8 Slot from CPU2 Slot3 PCI Expre...

Страница 37: ...WR2 must also be connected to the power supply See the table on the right for pin defini tions Required Connection 12V 8 pin Power Pin Definitions Pins Definition 1 4 Ground 5 8 12V Warning To provide adequate power supply to the serverboard be sure to connect J24 and both JPWR1 and JPWR2 to the power supply Failure to do so will void the manufacturer warranty on your power supply and serverboard ...

Страница 38: ...ght for pin definitions PWR Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 PWR Supply Fail Fan Headers There are nine fan headers on the serverboard all of which are 4 pin fans Pins 1 3 of the fan headers are backward compatible with the traditional 3 pin fans Fan speed control is supported with 4 pin fans only See the table on the right for pin definitions The onboard fan speeds are control...

Страница 39: ...luded See the tables on the right for pin definitions SGPIO Headers The SGPIO Serial General Purpose Input Output headers are used to communicate with the enclosure management chip on the backplane T SGPIO1 2 support the I SATA ports and S SGPIO1 supports the S SATA ports See the table on the right for pin definitions SGPIO Header Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 ...

Страница 40: ... front UID LED is located on pin 7 on JF1 When you press the front or rear UID switch both front and rear UID LEDs will be turned on Press the UID switch again to turn off the LED indicators These indicators provide easy identification of a system unit that may be in need of service Note UID can also be triggered via IPMI For more information on IPMI please refer to the IPMI User s Guide posted on...

Страница 41: ...ght for jumper settings VGA Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled I2 C to PCI E Slots Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled I2 C Bus to PCI Exp Slots Jumpers JI2 C1 and JI2 C2 allow you to connect the System Management Bus I2 C to the PCI Express slots to improve PCI performance The default setting is Enab...

Страница 42: ...of the connection See the table on the right for the functions associ ated with the connection speed LED LAN1 2 LED Connection Speed Indicator LED Color Definition Off No link 10 or 100 Mbps Green 10 Gbps Amber 1 Gbps Onboard Power LED LE1 An Onboard Power LED is located at LE2 This LED Indicator is lit when the system is on Be sure to unplug the power cable before removing or adding any component...

Страница 43: ...cro com Some of these must be installed such as the chipset driver After accessing the FTP site go into the CDR_Images directory and locate the ISO file for your serverboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is to go to the Supermicro website at http www supermicro com produc...

Страница 44: ...TP and SMTP services to optimize the efficiency of your operation Note The default User Name and Password for SuperDoctor 5 is admin admin Figure 5 7 SuperDoctor 5 Interface Display Screen Health Information Note The SuperDoctor 5 program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products nfo sms_sd5 cfm 5 13 Onboard Battery Care must be taken to a...

Страница 45: ...5 30 SUPERSTORAGESYSTEM 6048R E1CR36N User s Manual Notes ...

Страница 46: ...s To prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its com...

Страница 47: ... all excess cabling out of the airflow path The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons Details on JF1 can be found in Chapter 5 Hard Drives 24 Control Panel 6 3 Removing the Chassis Cover Figure 6 2 Removing the Chassis Cover Warning Except for short periods of time do NOT operate the server without the chassis cover in place The cover ...

Страница 48: ...as failed 2 Depress the tab on the side of the fan to unlock and remove the fan along with its housing The fan s power connections will automatically detach 3 System power does not need to be shut down since the fans are hot plugga ble 4 Replace the failed fan with an identical 8 cm 12 volt fan available from Supermicro 5 Position the new fan into the space vacated by the failed fan previously re ...

Страница 49: ...y drive Place the hard drive tray on a flat surface such as a desk table or work bench see Figure 6 4 2 Slide the hard drive into the tray with the printed circuit board side facing down 3 Carefully align the mounting holes in both the drive tray and the hard drive 4 Secure the hard drive to the tray using six screws 5 Replace the drive tray into the chassis Make sure to close the drive tray handl...

Страница 50: ...ard drive or two 2 5 fixed hard drives These brackets install under the serverboard tray Each chassis can accomodate up to two of these brackets to support up to two 3 5 hard drives or up to four 2 5 hard drives tray p n MCP 220 84701 0N Installing One 3 5 HDD Installing Two 2 5 HDDs Installing the Bracket onto the Chassis Installing a 3 5 Hard Drive into the Bracket 1 Align the four washers and s...

Страница 51: ...s being connected Please follow the instructions provided with the JBOD Release Tab DC Power The AC power supplies may be removed and replaced with a DC power supply Replacing the AC Power Supply with a DC Power Supply 1 Shut down the system and unplug the AC power cord 2 Remove the AC power supply as described in the procedure above 3 Install the DC power supply into the empty power bay 4 Connect...

Страница 52: ...6 12 SUPERSTORAGESYSTEM 6048R E1CR36N User s Manual Figure 6 9 JBOD Expansion Port JBOD OUT downstream ports Note the use of two cables 8x SAS lanes is recommended ...

Страница 53: ...gend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Note the AMI BIOS has default text messages built in Supermicro retains the option to include omit or change any of these text messages The AMI BIOS setup utility uses a key based navigation system called hot keys Most of th...

Страница 54: ...ed of the memory modules installed in the system How to Start the Setup Utility Normally the only visible Power On Self Test POST routine is the memory test As the memory is being tested press the Delete key to enter the main menu of the AMI BIOS setup utility From the main menu you can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the s...

Страница 55: ...ure Interrupt 19 at bootup immediately and allow the drives that are attached to the host adap tors to function as bootable disks If this item is set to Postponed the ROM BIOS of the host adaptors will not capture Interrupt 19 immediately to allow the drives attached to the adaptors to function as bootable devices at bootup The options are Immediate and Postponed Re try Boot Select EFI Boot to all...

Страница 56: ...nd Disable DCU Mode Use this feature to set the data prefecting mode for the DCU Data Cache Unit The options are 32KB 8Way Without ECC and 16KB 4Way With ECC Direct Cache Access DCA Select Enable to use Intel DCA Direct Cache Access Technology to improve the efficiency of data transferring and accessing The options are Auto Enable and Disable DCA Prefetch Delay A DCA prefetcher is used with a TOE ...

Страница 57: ... and Disable Config TDP Level Available when Config TDP above is set to Enable Use this item to set TDP configuration level to enhance thermal management The options are Nominal Level 1 and Level 2 CPU P State Control Available when Power Technology is set to Custom EIST P States EIST Enhanced Intel SpeedStep Technology allows the system to automatically adjust the processor voltage and core frequ...

Страница 58: ... voltage scaled back a notch The options are Between P1 P0 and Below P1 Short Duration Power Limit Enable Select Enable to support Short Duration Power Limit Power Limit 2 The options are Enable and Disable Short Duration Power Limit This item displays the time period during which short duration power is main tained The default setting is 0 Package Clamping Limit2 Use this item to set the limit on...

Страница 59: ... the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto II02 PORT 3A Link Speed This item configures the link speed of a PCI E port specified by the user The options are Gen 1 Generation 1 2 5 GT s Gen 2 Generation 2 5 GT s and Gen 3 Generation 3 8 GT s II02 PORT 3C Link Speed This item configures the link speed of a PCI E...

Страница 60: ...ort to enhance system performance in cloud computing The options are Enable Disable and Auto Early Snoop Available when the OS and the CPU support this feature Select Enable for Early Snoop support to enhance system performance The options are Enable Disable and Auto Isoc Mode Select Enable for Isochronous support to meet QoS Quality of Service require ments This feature is especially important fo...

Страница 61: ...boost performance The options are Disable Mirror and Lockstep Mode Lockstep x4 DIMMs Select Enable to enable Lockstep support for x4 DIMM modules The options are Auto Disabled and Enabled Memory Rank Sparing Select Enable to enable memory sparing support for memory ranks to improve memory performance The options are Disabled and Enabled Patrol Scrub Patrol Scrubbing is a process that allows the CP...

Страница 62: ...ed and Enabled Port 60 64 Emulation Select Enabled to support I O port 60h 64h emulation which will provide complete legacy USB keyboard support for the operating systems that do not support legacy USB devices The options are Disabled and Enabled USB 3 0 Support Select Enabled for USB 3 0 support The options are Smart Auto Auto Enabled Disabled and Manual EHCI1 Select Enabled to enable EHCI Enhanc...

Страница 63: ...ions are Enabled and Disabled Port 0 Port 5 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The options are Enabled and Disabled Port 0 Port 5 SATA Device Type Use this item to specify if the SATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If t...

Страница 64: ... number of drive and capacity Software Preserve sSATA Port 0 Port 3 Select Enabled to enable an sSATA port specified by the user The options are Disabled and Enabled sSATA Port 0 Port 3 Hot Plug Select Enabled to enable hot plugging support for a port specified by the user which will allow the user to replace a sSATA disk drive installed on this port without shutting down the system The options ar...

Страница 65: ...Device Common Settings PCI Latency Timer Use this item to configure the PCI latency timer for a device installed on a PCI bus Select 32 to set the PCI latency timer to 32 PCI clock cycles The options are 32 64 96 128 160 192 224 and 248 PCI Bus Clocks PCI X Latency Timer Use this item to configure the PCI X latency timer for a device installed on a PCI bus Select 32 to set the PCI latency timer to...

Страница 66: ...to select the type of device installed in LAN Port1 LAN Port2 or the onboard video device used for system boot The default settings for LAN1 Option ROM is PXE for LAN2 LAN3 LAN4 Option ROMs are Disabled and for Onboard Video Option ROM is Legacy VGA Priority Use this item to select the graphics device to be used as the primary video display for system boot The options are Onboard and Offboard Supe...

Страница 67: ...Start signal to start sending data when the receiving buffer is empty The options are None and Hardware RTS CTS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabl...

Страница 68: ...options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Dis abled and Enabled Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty whic...

Страница 69: ...d Platform Module settings to enhance system data security Please reboot your system for any change on the TPM state to take effect The options are Disabled and Enabled Pending Operation Use this item to schedule a TPM related operation to be performed by a security device for system data integrity Your system will reboot to carry out a pending TPM operation The options are 0 Enable Take Ownership...

Страница 70: ...fault setting is 10 Erasing Settings Erase Event Log Select Yes to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The options are No and Yes When Log is Full Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full Select Do Nothing for the system to do nothing when the SMBIOS event...

Страница 71: ...he changes to take effect BMC Network Configuration The following items will be displayed IPMI LAN Selection IPMI Network Link Status Update IPMI LAN Configuration Select Yes for the system BIOS to automatically reset the following IPMI settings at next system boot The options are Yes and No Configuration Address Source Available when the item above Update IPMI LAN Configuration is set to Yes Use ...

Страница 72: ...se this feature to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 char acters long 7 7 Boot Settings Use this feature to configure Boot Settings Boot Configuration Setup Prompt Timeout Use this item to indicate how many seconds the system shall wait for the BIOS setup activation key to respond before the system s...

Страница 73: ...BIOS setup without making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configura tion parameters to take effect Select Save Change...

Страница 74: ... settings for future use Restore User Defaults Select this item and press Enter to retrieve user defined settings that were previ ously saved for future use Boot Override This feature allows the user to override the Boot priorities sequence in the Boot menu and immediately boot the system with another device specified by the user This is a one time override ...

Страница 75: ...cturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the cor responding error Motherboard BIOS Error Beep Codes Beep Code LED Error Message Description 1 beep Refresh Ready to boot 5 short beeps 1 long beep Memory error No memory detected in the system 5 beeps No Con In or...

Страница 76: ...A 2 SUPERSTORAGESYSTEM 6048R E1CR36N User s Manual Notes ...

Страница 77: ... of ECC LRDIMM Load Reduced DIMMs or 1 5 TB of ECC RDIMM Registered DIMMs DDR4 2400 2133 1866 1600 memory Note see Section 5 6 for details Drive Bays Thirty six hot swap drive bays to house SAS or SATA drives 24 in front 12 in rear Expansion Slots Up to two PCI E x16 three PCI E 3 0 x8 and one PCI E 2 0 x4 in a x8 slot cards may be added to the system Note that some PCI slots may not be enabled if...

Страница 78: ...ronment Operating Temperature 10º to 35º C 32º to 95º F Non operating Temperature 40º to 70º C 40º to 158º F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61...

Страница 79: ... to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and a...