INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, 
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the 
rating plate. This appliance is not convertible for use with other gases.

WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built 
fi replace or in a listed ventless fi rebox enclosure. It is design-certifi ed for these installations in accordance 
with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fi replace that includes 
instructions stating it has not been tested or should not be used with unvented gas logs.

This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. Provisions 
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation 
section on 

Page 6

 of this manual.

Installation and Operation Instructions

Unvented (Vent-Free) Gas Log Heater

Models

PFS

®

US

Report No. F10-087

FVFM27NR

FVFM27PR

P/N 126848-01    REV. B   05/2017

 

P126848-01

       

WARNING:

FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

-   Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other 

appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 
•  Do not touch any electrical switch; do not use any phone in your building. 
•  Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s instructions. 
•  If you cannot reach your gas supplier, call the fi re department.

 -  Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.

Содержание FVFM27NR

Страница 1: ...en from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual Installat...

Страница 2: ...cordance with ANSI Z21 11 2 Exception DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs...

Страница 3: ...is your guide to safe and proper operation of this heater Due to high temperatures the ap pliance should be located out of traffic and away from furniture and draperies Do not place clothing or other...

Страница 4: ...there are no obstructions across openings of fireplace 9 This log heater is designed to be smokeless If logs ever appear to smoke turn off heater and call a qualified service person NOTE During initi...

Страница 5: ...of local codes use the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 Available from American National Standards Institute Inc 25 West 43rd Street 4th floor New York NY 10036 Nationa...

Страница 6: ...perate You must provide adequate fresh air for these appliances This will ensure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from Nationa...

Страница 7: ...r openings add the volume of these rooms to the total volume of the space 2 Multiply the space volume by 20 to determine the maximum Btu Hr the space can support ________ volume of space x 20 Maxi mum...

Страница 8: ...to Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma n...

Страница 9: ...orslocated on floor or wall of fireplace If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the heater in a bedroom or...

Страница 10: ...at Resistant Material Slate Marble Tile etc Above Fireplace MINIMUM NONCOMBUSTIBLE MATERIAL CLEARANCES If Not Using Mantel NOTE If using a mantel proceed to If Using Mantel Page 11 If not using a mant...

Страница 11: ...eight Distances to Underside of Mantel Top of Fireplace Opening Underside of Mantel Shelf Mantel Shelf 12 A 18 20 22 24 All minimum distances are in inches 2 1 2 6 8 10 Figure 7 Minimum Mantel Clearan...

Страница 12: ...stallation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue open ing will be maintai...

Страница 13: ...in a brick bottom fireplace mark screw locations in mortar joint of bricks 8 Remove heater base from fireplace If installing optional control accessories do so at this time Follow all directions provi...

Страница 14: ...ator for propane LP units only supplied by installer piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench For...

Страница 15: ...Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG...

Страница 16: ...1 Figure 17 Checking Gas Joints for Propane LP Gas Figure 16 Checking Gas Joints for Natural Gas Gas Meter Equipment Shutoff Valve Control Valve Location Control Valve Location Propane LP Supply Tank...

Страница 17: ...h must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is...

Страница 18: ...0 Wait one minute and switch selector switch to the ON position to light burner NOTE AUTO is only functional when using GWMT1 or GWMS2 optional ac cessories Figure 22 Control Knob and Igniter Button L...

Страница 19: ...Operation Selector Switch in Remote Position Optional Hand Held Remote Control ON OFF REMOTE O F F PILOT LO IH O N Control Knob in On Position Flame Adjustment Knob Piezo Igniter MANUAL LIGHTING PROC...

Страница 20: ...9 see Troubleshooting Page 23 NOTE The pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color BURNER PRIMARY AIR HOLES Air is drawn into...

Страница 21: ...mount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt lint and pet hair Clean these air in let holes prior to each heating season Blocked air holes w...

Страница 22: ...about instal lation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your appliance r...

Страница 23: ...ep igniter cable dry 3 Tighten nut holding piezo igniter to base panel of log set Nut is located behind base panel 4 Replace igniter cable 5 Replace piezo igniter 6 Replace pilot assembly 7 Replace pi...

Страница 24: ...does not light after ODS pilot is lit 1 Burner orifice clogged 2 Inlet gas pressure is too low 3 Thermopile leads discon nected or improperly con nected 4 Burners will not come on in remote position...

Страница 25: ...ral or propane LP gas company 3 Observe minimum instal lation clearances see Pages 10 through 12 4 Clean burner see Clean ing and Maintenance Page 21 or replace burn er orifice White powder residue fo...

Страница 26: ...mi cals new carpet etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of page 1 Open window and venti late room Stop using odor causing products while heater is running 2 Locate...

Страница 27: ...10 9 23 22 1 3 1 1 1 5 1 4 1 2 PARTS MODELS FVFM27NR AND FVFM27PR NOTE Part numbers 22 and 23 are for natural gas model only CAT NO MODEL F0073 FVFM27NR F0074 FVFM27PR WARNING Failure to position the...

Страница 28: ...9 J8089 Burner Retainer Spring 1 7 J3604 J3605 Burner Orifice Injector 1 8 J3900 J3900 Burner 1 9 J3660 J8090 Pilot Tube Regulator to Pilot 1 10 J3836 J3837 Gas Control Valve 1 11 J8091 J8091 Lower Br...

Страница 29: ...For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to 48 wide DECORATIVE ASH BED CONTROL COVER KIT SIX PACK Cat No F1759 Model CDABKA 6 DECORATIVE ASH BED CONT...

Страница 30: ...lled mode Remote is programmable for your convenience and has a large bright LCD Touch Screen for easy use MODE SET PROG ON OFF REMOTE AND RECEIVER WITH WHITE WALL PLATE Cat No F2236 Model RCKIT 4001...

Страница 31: ...ll produce excessive temperatures and could result in a re hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d...

Страница 32: ...r local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126848 01 Rev B 05 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 SuperiorFireplaces us co...