Superior B-40REN Скачать руководство пользователя страница 1

1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

INSTALLATION
INSTRUCTIONS

STANDARD SERIES

36" B-VENTED GAS APPLIANCES
P/N  700,003M  REV.  H  05/2004

Millivolt Models

Electronic Models

B-40RMN

B-40REN

B-40RMP

B-40REP

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

WH Report No. J20006722

MODELS

FOR YOUR SAFETY:  Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.

FOR YOUR SAFETY:  What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone. Follow your gas suppliers
instructions.

• If your gas supplier cannot be reached, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.

This appliance may be installed in an after-
market permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by local codes. This appliance is
only for use with the type of gas indicated on
the rating plate. This appliance is not convert-
ible for use with other gases, unless a certi-
fied kit is used.

POUR VOTRE SÉCURITÉ:  Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.

POUR VOTRE SÉCURITÉ:  Que faire si vous sentez une
odeur de gaz:

• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur.  Ne pas vous servir

des téléphones se trouvant dans le batiment où
vous vous trouvez.

• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz

depuis un voisin.  Suivez les instructions du
fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service dos incendies.

L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.

Содержание B-40REN

Страница 1: ...e may be installed in an after market permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on...

Страница 2: ...that the control compartment burners and circulating airpassagewaysoftheappliancebekeptclean S assurerquelebr leuretlecompartimentdes commandes sont propres Voir les instruc tions d installation et d...

Страница 3: ...S APPLIANCE CAN CAUSE SERI OUS INJURY OR DEATH FORM FIRE BURNS EXPLOSION OR CARBON MON OXIDE POISONING WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OFHIGHSURFACETEMPERATURES USE CAUTIO...

Страница 4: ...2 4 Roof Slope Feet Meters MultipleTerminations Theseappliancesmay vent adjacent to and at the same level with any other gas appliances including direct vent appliances provided that there is at least...

Страница 5: ...NSTALLATION SEQUENCE The typical sequence of installation follows however each installation is unique resulting in variations to those described 1 Construct the appliance framing 2 Route gas supply li...

Страница 6: ...m the left side When rigid pipe is used an ANSI approved manual shut off valve and union must be in stalled upstream of the fireplace Ensure that a sediment trap is installed in the existing gas line...

Страница 7: ...ronic appliances A Millivolt Wiring Units may be fitted at the factory with either a Honeywell millivolt gas control valve or an SIT millivolt gas control valve Both valves have been tested with and a...

Страница 8: ...or partially blocked clean out the ports Step 7 Installing Outside Air Kit These appli ances are equipped with an outside make up air door and integral actuator arm If the appli ance is to be install...

Страница 9: ...As located at the factory the log set will require no adjust ment before the appliance is placed in service Ensurelogsareunbrokenandlocatedasshown To provide increased access to the lower con trol co...

Страница 10: ...ition Ensure the ignitor lights the pilot The pilot flame should engulf the flame rod as shown in Figure 23 Step 10 Adjustments The following para graphs address adjustment concerns and pro cedures Fl...

Страница 11: ...pliance front face black sheet metal Never allow combustible materials to be positioned in front of or overlapping the appliance front face FINISHING REQUIREMENTS Wall Details and Combustible Mantels...

Страница 12: ...erly positioned and install the new pressure regulator using the new screws supplied with the kit Tighten screws to 25 In lb torque Step 5 Honeywell Systems See Figure 28 and the instructions provide...

Страница 13: ...the one provided with the conversion kit Reinstall the pilot assembly by reversing the steps detailed here When reinstalling the ignitor assembly use extreme care to prevent damage and break age Do n...

Страница 14: ...14 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE...

Страница 15: ...15 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE...

Страница 16: ...00 003M REV H 05 2004 LHP 1110 West Taft Avenue Orange CA 92865 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to dis...

Отзывы: